Spatially Resolved Wavefront Aberrations of Ophthalmic Progressive-Power Lenses in Normal Viewing Conditions
The DOI matches its OpenAlex record.
Abstract
PURPOSE: To measure the wavefront aberration at different locations in progressive-power lenses (PPL's) isolated and in situ (PPL's plus eye). METHODS: A Hartmann-Shack wavefront sensor was used to measure progressive-power lenses and human eyes either independently or in combination. In each selected zone, the lens was placed and tilted accordingly to simulate natural viewing conditions. We measured 21 relevant locations across an isolated PPL (plano lens of power addition of 2 D). In six of the locations, the wavefront aberration of the eye plus PPL were obtained in two ways: (1) by direct measurement of the system and (2) by adding the individual wavefront aberrations of the eye and the lens for each appropriate zone. In every case, we obtained the wavefront aberration as Zernike polynomials expansions, the root mean square error, the point-spread function, and the Strehl ratio. RESULTS: Along the corridor of the PPL, third-order coma and trefoil, and astigmatism were the dominant aberrations. In areas of the PPL outside the corridor, astigmatism increased, whereas other aberrations remained similar to the lens center. Small differences were found between the direct and calculated methods used to obtain the wavefront aberration of the eye with the lens, and the possible sources of errors were discussed. In some lenses zones, the aberrations of the lens may be compensated by the particular aberrations of the eye, yielding improved optical performance over that present in the lens alone. CONCLUSIONS: We designed and built a wavefront sensor to perform spatially resolved aberration measurements in ophthalmic lenses, in particular in PPL's, either isolated or in combination with the eye. The aberrations appearing in the PPL were compared with those in normal aged eyes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neural compensation for the eye’s optical aberrations
Artal, P., Chen, L., Fernández, E. J., Singer, B., Manzanera, S., & Williams, D. R. (2004) · Journal of Vision · doi:10.1167/4.4.4 · Cited by 332
Self-citationProgress in the spectacle correction of presbyopia. Part 2: modern progressive lens technologies
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2008.00246.x · Cited by 87
Comparison of aberrations in different types of progressive power lenses
Villegas, E. A., & Artal, P. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00214.x · Cited by 32
“In a recent study (Villegas and Artal, 2003), we measured wave-aberrations at different locations of a PPL and the coupling with the aberrations of the eye.”
BackgroundMethodSelf-citationOptical performance of progressive addition lenses (PALs) with astigmatic prescription
De Lestrange-Anginieur, E., & Kee, C. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-82697-0 · Cited by 9
Metadata
- Authors
- Villegas, E. A., & Artal, P.
- Venue
- Optometry and Vision Science
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2003-02-01
- Volume
- 80
- Issue
- 2
- Pages
- 106-114
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2022608852
- Cited by
- 65
- References
- 0
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatially Resolved Wavefront Aberrations of Ophthalmic Progressive-Power Lenses in Normal Viewing Conditions. https://app.cochat.ai/papers/10.1002/j.1538-9235.2003.tb01601.x
- The paper
- Villegas, E. A., & Artal, P. (2003). Spatially Resolved Wavefront Aberrations of Ophthalmic Progressive-Power Lenses in Normal Viewing Conditions. Optometry and Vision Science. https://doi.org/10.1002/j.1538-9235.2003.tb01601.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.