CoChat

Optical performance of progressive addition lenses (PALs) with astigmatic prescription

Open access
De Lestrange-Anginieur, E., Kee, C. S. · 2021 · Scientific Reports

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

The progressive addition lens (PAL) is a spectacle lens design with progressive refractive power changes across the lens surface to provide sharp vision at different viewing distances for patients with reduced accommodative strength. It has gained in popularity not just for presbyopic patients, but also patients with occupational (office, driving, or digital device) and therapeutic (e.g., myopia control) needs. However, despite the increasing prevalence of astigmatism in adults > 40 years old who rely on PAL correction, no metric is available to reflect the optical variation in PALs with astigmatic prescriptions. Based on recent studies, four novel optical metrics sensitive to variation of refractive power across the lens surface of PALs have been developed. These metrics were used to compare the optical performance of PALs of various prescriptions, designs, and manufacturers. For each lens, the refractive power profile was first measured with a Moire-deflectometry-based instrument.The data was then exported and analyzed using a two-dimensional error map for each of the four metrics. The results revealed significant impacts of astigmatic prescription, providing evidence for the usefulness of these metrics in quantifying the optical performance of PALs for patients with astigmatic prescriptions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-021-82697-0

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Measurement of refractive power profile. (A) The Rotlex Free Form Verifier system with graphic user interface (left) and positioning device (right). Note that the tested PAL was set with the front surface facing downwards. (B) The two standard engraved symbols of the PAL marked with a fine-tip marker and positioned within the green rings (arrows) appeared on the graphic user interface. (C) The flow chart summarizes the measurement procedure.
Figure 1 Measurement of refractive power profile. (A) The Rotlex Free Form Verifier system with graphic user interface (left) and positioning device (right). Note that the tested PAL was set with the front surface facing downwards. (B) The two standard engraved symbols of the PAL marked with a fine-tip marker and positioned within the green rings (arrows) appeared on the graphic user interface. (C) The flow chart summarizes the measurement procedure.CC BY · PubMed Central
Figure 2 Derivation of cylindrical errors at different locations (x,y) on the lens surface. (A) Actual cylindrical refractions Jactual at three separate locations (black symbols) on the lens surface are represented by their respective J0 and J45 coordinates. Cylindrical error at each position is quantified by subtracting the target Jtarget (red circle) from the actual Jactual (black symbols), as indicated by the arrowhead. (B) An error map is constructed by computing the cylindrical error for each location on the lens surface. Cylindrical errors computed for the three locations in (A) are represented by open symbols. The color gradient highlights the levels of mismatch between actual and target cylinder power, which progressively increases from blue to red colors.
Figure 2 Derivation of cylindrical errors at different locations (x,y) on the lens surface. (A) Actual cylindrical refractions Jactual at three separate locations (black symbols) on the lens surface are represented by their respective J0 and J45 coordinates. Cylindrical error at each position is quantified by subtracting the target Jtarget (red circle) from the actual Jactual (black symbols), as indicated by the arrowhead. (B) An error map is constructed by computing the cylindrical error for each location on the lens surface. Cylindrical errors computed for the three locations in (A) are represented by open symbols. The color gradient highlights the levels of mismatch between actual and target cylinder power, which progressively increases from blue to red colors.CC BY · PubMed Central
Figure 3 Vectorial differences due to difference in astigmatic axis. Actual (blue square) and target (red circles) refractive prescriptions (− 4.00 DS/− 2.00 DC × 90 and − 4.00 DS/− 2.00 DC × 180) with identical spherical equivalent and cylinder magnitude (J) are used as examples. Since all prescriptions have identical spherical equivalent, they lie on the same astigmatic plane. All prescriptions lie on the big blue circle, representing a common cylinder magnitude of J. The symbol ΔJ^α stands for the unwanted errors after subtracting the target (with axis α=0 and 90) from the actual prescriptions. Note that in this example, the first metric (JCC error map) predicts the same optical performance for the two prescriptions (ΔJα=0). The second metric (vectorial error map) ΔJ45 components also could not differentiate between the two prescriptions when compared to the target prescription, but the different ΔJ0 components for different axes (α=0 and 90) predicted different optical performance (see text for details).
Figure 3 Vectorial differences due to difference in astigmatic axis. Actual (blue square) and target (red circles) refractive prescriptions (− 4.00 DS/− 2.00 DC × 90 and − 4.00 DS/− 2.00 DC × 180) with identical spherical equivalent and cylinder magnitude (J) are used as examples. Since all prescriptions have identical spherical equivalent, they lie on the same astigmatic plane. All prescriptions lie on the big blue circle, representing a common cylinder magnitude of J. The symbol ΔJ^α stands for the unwanted errors after subtracting the target (with axis α=0 and 90) from the actual prescriptions. Note that in this example, the first metric (JCC error map) predicts the same optical performance for the two prescriptions (ΔJα=0). The second metric (vectorial error map) ΔJ45 components also could not differentiate between the two prescriptions when compared to the target prescription, but the different ΔJ0 components for different axes (α=0 and 90) predicted different optical performance (see text for details).CC BY · PubMed Central
Figure 4 Error maps of spherical power, ΔM. (A) Mean and (B) standard deviation of the error maps at distant viewing distance for four lenses (2 models × 2 corridor lengths) with the same prescription (columns) from the three lens manufacturers (rows: H Hoya, E Essilor, Z Zeiss). (C) and (D) show mean absolute differences of the error maps for PALs of different models and corridor lengths, respectively. Note that the scales of color-coded maps are different.
Figure 4 Error maps of spherical power, ΔM. (A) Mean and (B) standard deviation of the error maps at distant viewing distance for four lenses (2 models × 2 corridor lengths) with the same prescription (columns) from the three lens manufacturers (rows: H Hoya, E Essilor, Z Zeiss). (C) and (D) show mean absolute differences of the error maps for PALs of different models and corridor lengths, respectively. Note that the scales of color-coded maps are different.CC BY · PubMed Central
Figure 5 Error maps of JCC, ΔJα. (A) Mean and (B) standard deviation of the error maps for four lenses (2 models × 2 corridor lengths) with the same prescription (columns) from the three lens manufacturers (rows: H Hoya, E Essilor, Z Zeiss). (C) and (D) show mean absolute differences of the error maps for PALs of different models and corridor lengths, respectively. Note that the scales of color-coded maps are different.
Figure 5 Error maps of JCC, ΔJα. (A) Mean and (B) standard deviation of the error maps for four lenses (2 models × 2 corridor lengths) with the same prescription (columns) from the three lens manufacturers (rows: H Hoya, E Essilor, Z Zeiss). (C) and (D) show mean absolute differences of the error maps for PALs of different models and corridor lengths, respectively. Note that the scales of color-coded maps are different.CC BY · PubMed Central
Figure 6 Error maps of vectorial cylinder, ΔJv. (A) Mean and (B) standard deviation of the error maps for four lenses (2 models × 2 corridor lengths) with the same prescription (columns) from the three lens manufacturers (rows: H Hoya, E Essilor, Z Zeiss). (C) and (D) show mean absolute differences of the error maps for PALs of different models and corridor lengths, respectively. Note that the scales of color-coded maps are different.
Figure 6 Error maps of vectorial cylinder, ΔJv. (A) Mean and (B) standard deviation of the error maps for four lenses (2 models × 2 corridor lengths) with the same prescription (columns) from the three lens manufacturers (rows: H Hoya, E Essilor, Z Zeiss). (C) and (D) show mean absolute differences of the error maps for PALs of different models and corridor lengths, respectively. Note that the scales of color-coded maps are different.CC BY · PubMed Central
Figure 7 Error maps of overall refraction ΔL. (A) Mean and (B) standard deviation of the error maps at distant viewing distance for four lenses (2 models × 2 corridor lengths) with the same prescription (columns) from the three lens manufacturers (rows: H Hoya, E Essilor, Z Zeiss). (C) and (D) show mean absolute differences of the error maps for PALs of different models and corridor lengths, respectively. Note that the scales of color-coded maps are different.
Figure 7 Error maps of overall refraction ΔL. (A) Mean and (B) standard deviation of the error maps at distant viewing distance for four lenses (2 models × 2 corridor lengths) with the same prescription (columns) from the three lens manufacturers (rows: H Hoya, E Essilor, Z Zeiss). (C) and (D) show mean absolute differences of the error maps for PALs of different models and corridor lengths, respectively. Note that the scales of color-coded maps are different.CC BY · PubMed Central
Figure 8 Area of clear vision for different PALs, metric ΔJα. (A) Binary image showing area of clear vision (yellow) and area with ΔJα more than ± 0.25D from the target prescription (dark blue). The calculations in each plot were based on data of four lenses with the same prescription. H Hoya, E Essilor, Z Zeiss. (B) Proportion of clear vision area as a function of PAL prescription. The proportion was calculated as the area of clear vision to the total area of measurement. Error bars represent standard errors.
Figure 8 Area of clear vision for different PALs, metric ΔJα. (A) Binary image showing area of clear vision (yellow) and area with ΔJα more than ± 0.25D from the target prescription (dark blue). The calculations in each plot were based on data of four lenses with the same prescription. H Hoya, E Essilor, Z Zeiss. (B) Proportion of clear vision area as a function of PAL prescription. The proportion was calculated as the area of clear vision to the total area of measurement. Error bars represent standard errors.CC BY · PubMed Central
Figure 9 Area of clear vision for different PALs, metric ΔJv. (A) Binary image showing area of clear vision (yellow) and area with ΔJv more than ± 0.25D from the target prescription (blue). The calculations in each plot were based on data of four lenses with the same prescription. H Hoya, E Essilor, Z Zeiss. (B) Proportion of clear vision area as a function of PAL prescription. The proportion was calculated as area of clear vision to the total area of measurement. Error bars represent standard errors.
Figure 9 Area of clear vision for different PALs, metric ΔJv. (A) Binary image showing area of clear vision (yellow) and area with ΔJv more than ± 0.25D from the target prescription (blue). The calculations in each plot were based on data of four lenses with the same prescription. H Hoya, E Essilor, Z Zeiss. (B) Proportion of clear vision area as a function of PAL prescription. The proportion was calculated as area of clear vision to the total area of measurement. Error bars represent standard errors.CC BY · PubMed Central
Figure 10 Area of clear vision of different PALs for distant, intermediate, and near viewing distances, metric ΔM. (A) Binary image showing area of clear vision (yellow) and area with ΔM more than ± 0.25D from the target prescription (blue). The calculations in each plot were based on data of four lenses with the same prescription. H Hoya, E Essilor, Z Zeiss. (B) Proportion of clear vision area as a function of PAL prescription. The proportion was calculated as area of clear vision to the total area of measurement. Error bars represent standard errors.
Figure 10 Area of clear vision of different PALs for distant, intermediate, and near viewing distances, metric ΔM. (A) Binary image showing area of clear vision (yellow) and area with ΔM more than ± 0.25D from the target prescription (blue). The calculations in each plot were based on data of four lenses with the same prescription. H Hoya, E Essilor, Z Zeiss. (B) Proportion of clear vision area as a function of PAL prescription. The proportion was calculated as area of clear vision to the total area of measurement. Error bars represent standard errors.CC BY · PubMed Central
Figure 11 Area of clear vision of different PALs for near, intermediate, and far distance metric ΔL. (A) Binary image showing area of clear vision (yellow) and area with ΔL more than ± 0.25D from the target prescription (blue). The calculations in each plot were based on data of four lenses with the same prescription. H Hoya, E Essilor, Z Zeiss. (B) Proportion of clear vision area as a function of PAL prescription. The proportion was calculated as area of clear vision to the total area of measurement. Error bars represent standard errors.
Figure 11 Area of clear vision of different PALs for near, intermediate, and far distance metric ΔL. (A) Binary image showing area of clear vision (yellow) and area with ΔL more than ± 0.25D from the target prescription (blue). The calculations in each plot were based on data of four lenses with the same prescription. H Hoya, E Essilor, Z Zeiss. (B) Proportion of clear vision area as a function of PAL prescription. The proportion was calculated as area of clear vision to the total area of measurement. Error bars represent standard errors.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Research works printed but not linked: 2

  1. Jalie, M. Ophthalmic Lenses and Dispensing 3rd edn, 169–175 (Butterworth-Heinemann, Edinburgh, 2008).
  2. Raasch, T. Sphero-cylindrical defocus and visual acuity. Optom. Vis. Sci. 72, 272–275 (1995). · DOI

Cited by

See all 13

Metadata

Authors
De Lestrange-Anginieur, E., & Kee, C. S.
Affiliations
Hong Kong Polytechnic University (HK)
Venue
Scientific Reports
Published
2021-02-04
Volume
11
Issue
1
Pages
2984-2984
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3127710654
Cited by
9
References
28
Citations by year
2026: 4 · 2025: 1 · 2024: 1 · 2023: 2 · 2021: 1
FWCI
0.72
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion, cc-by)
Funders
Shenzhen Fundamental Research and Discipline Layout project (JCYJ20160331185006518)
Topics
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced optical system design
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
Keywords
progressive addition lenses, astigmatism, moiré deflectometry, error maps, spectacle lens design, presbyopia, myopia control, accommodative insufficiency
MeSH terms
Accommodation, Ocular, Astigmatism, Eyeglasses, Humans, Myopia, Refraction, Ocular, Vision, Ocular, Visual Acuity, Prescriptions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optical performance of progressive addition lenses (PALs) with astigmatic prescription. https://app.cochat.ai/papers/10.1038/s41598-021-82697-0
The paper
De Lestrange-Anginieur, E., & Kee, C. S. (2021). Optical performance of progressive addition lenses (PALs) with astigmatic prescription. Scientific Reports. https://doi.org/10.1038/s41598-021-82697-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.