A Randomized Comparison of Four Incisions for Orbital Fractures
The DOI matches its Crossref record.
Abstract
We previously compared conjunctival and subciliary incisions for exposure of orbital floor and infraorbital rim fractures. A prospective randomized comparison of lower eyelid and orbital rim incisions was then undertaken and results compared with our previous study. Lower eyelid and orbital rim incisions provided more rapid access to fracture sites. Fracture exposure was adequate with all but conjunctival incisions; lateral canthotomy was added in 56 percent of cases to improve exposure. There were minimal or no intraoperative and postoperative complications except for a 42 percent incidence of ectropion following subciliary incisions. Scar appearance was similar in the four groups, except when an isolated conjunctival incision was used, which produced an invisible scar.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Classification and treatment of zygomatic fractures: A review of 1,025 cases
Zingg, M., Laedrach, K., Chen, J., Chowdhury, K., Vuillemin, T., Sutter, F., & Raveh, J. (1992) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(92)90266-3 · Cited by 336
Ridgway, E. B., Chen, C., Colakoglu, S., Gautam, S., & Lee, B. T. (2009) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3181babb3d · Cited by 207
Transconjunctival Approach vs Subciliary Skin-Muscle Flap Approach for Orbital Fracture Repair
Appling, W. D., Patrinely, J. R., & Salzer, T. A. (1993) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1993.01880210090012 · Cited by 203
Melek, L. N., & Noureldin, M. G. (2023) · BMC Oral Health · doi:10.1186/s12903-023-03249-8 · Cited by 22
“Subramanian et al. recorded a familiar duration (22 min) as well as Holt-mann et al. (20 min) when performing the transconjucti-val approach with lateral canthotomy [5, 22].”
MethodZygomaticomaxillary buttress and its dilemma
Malaviya, P., & Choudhary, S. (2018) · Journal of the Korean Association of Oral and Maxillofacial Surgeons · doi:10.5125/jkaoms.2018.44.4.151 · Cited by 21
Song, S. H., Kwon, H., Oh, S.-H., Kim, S.-J., Park, J., & Kim, S. I. (2018) · Archives of Plastic Surgery · doi:10.5999/aps.2018.00311 · Cited by 9
“In particular, a subciliary incision can injure the orbicularis oculi muscle of the lower lid and decrease pretarsal fullness or cause aesthetically unfavorable results, such as lower eyelid retraction, both transient and permanent [9,10].”
BackgroundSingle incision technique for two-point fixation of zygomaticomaxillary complex fractures
Ramyadevi, S., Duraisamy, D., Balasubramanian, S., Gopalakrishnan, S., Duraisamy, K., & Rajiah, D. (2016) · Journal of Pierre Fauchard Academy (India Section) · doi:10.1016/j.jpfa.2016.11.003 · Cited by 3
Yassin, A., Shaaban, A., & Noureldin, M. (2021) · Alexandria Dental Journal · doi:10.21608/adjalexu.2021.67310.1168 · Cited by 2
“(22 min) for transconjunctival with lateral canthotomy approach (14,15).”
BackgroundChen, Y.-Y., Chen, T.-Y., Liang, C.-M., & Chou, P. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15051842 · Cited by 1
Sobhy, D. E., Dessoky, N. Y., Alryess, A. M., & Noureldin, M. G. (2026) · BMC Oral Health · doi:10.1186/s12903-026-08842-1
Metadata
- Authors
- Holtmann, B., Wray, R. C., & Little, A. G.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1981-06
- Volume
- 67
- Issue
- 6
- Pages
- 731-735
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2021438331
- Cited by
- 159
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.