A Clinical Comparison of the Tendency to Capsular Contracture Between Smooth and Textured Gel-Filled Silicone Mammary Implants
The DOI matches its Crossref record.
Abstract
The aim of this prospective, controlled clinical investigation was to find out if there is a difference in the capsular contracture rate between silicone implants with a smooth or textured surface as the only difference. Twenty-five women with bilateral mammary hypoplasia underwent mammary augmentation. All got a textured implant on one side and a smooth implant on the other. The implants were placed subglandularly. Follow-up examinations were done on six occasions. Three parameters were used for estimation of the tendency to capsular contracture: (1) the patient's opinion on differences in hardness of the breasts, (2) the investigator's classification of capsular contracture, and (3) applanation tonometry. At the end of the follow-up period, after 1 year, all parameters showed with no doubt that the breasts augmented with textured implants had a lower tendency to develop contracting capsules than the breasts augmented with smooth implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Barnsley, G. P., Sigurdson, L. J., & Barnsley, S. E. (2006) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000218184.47372.d5 · Cited by 345
Capsular Contracture after Breast Augmentation: An Update for Clinical Practice
Headon, H., Kasem, A., & Mokbel, K. (2015) · Archives of Plastic Surgery · doi:10.5999/aps.2015.42.5.532 · Cited by 343
Stevens, W. G., Nahabedian, M. Y., Calobrace, M. B., Harrington, J. L., Capizzi, P. J., Cohen, R., d’Incelli, R. C., & Beckstrand, M. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000435317.76381.68 · Cited by 289
Collett, D. J., Rakhorst, H., Lennox, P., Magnusson, M., Cooter, R., & Deva, A. K. (2019) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000005567 · Cited by 228
Jacombs, A., Tahir, S., Hu, H., Deva, A. K., Almatroudi, A., Wessels, W. L. F., Bradshaw, D. A., & Vickery, K. (2014) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000000020 · Cited by 201
How microbes read the map: Effects of implant topography on bacterial adhesion and biofilm formation
Lee, S. W., Phillips, K. S., Gu, H., Kazemzadeh-Narbat, M., & Ren, D. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2020.120595 · Cited by 198
Surface Engineered Polymeric Biomaterials with Improved Biocontact Properties
Vladkova, T. G. (2010) · International Journal of Polymer Science · doi:10.1155/2010/296094 · Cited by 166
“Some types of surface texture almost eliminate the fibrous capsules formation whereas other inhibits their collaps [94].”
BackgroundTopographical modulation of macrophage phenotype by shrink-film multi-scale wrinkles
Wang, T., Luu, T. U., Chen, A., Khine, M., & Liu, W. F. (2016) · Biomaterials Science · doi:10.1039/c6bm00224b · Cited by 77
Metadata
- Authors
- Hakelius, L., & Ohlsén, L.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1992-08
- Volume
- 90
- Issue
- 2
- Pages
- 247-254
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W4234866274
- Cited by
- 168
- References
- 0
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.