Shaping and Positioning the Nasal Tip Without Structural Disruption: A New, Systematic Approach
The DOI matches its Crossref record.
Abstract
This paper presents a new, comprehensive, and systematic approach to analysis, planning, and techniques of primary nasal tip rhinoplasty, emphasizing techniques that limit uncontrollable variables before proceeding to techniques which increase uncontrollable variables and risk secondary deformity, including (1) maintenance of structural integrity of the alar rim strips, limiting use of scoring or morselization techniques which reduce support and introduce potential secondary deformities, (2) shaping and positioning the lateral and medial crura in a reversible, nondestructive manner using permanent suture and nonvisible control graft techniques, (3) minimizing uncontrollable postoperative variables by decreasing the need for visible grafts to shape the tip complex in primary rhinoplasty, achieving the same results with existing alar structural elements, (4) integrating these concepts with specific sequences of surgical techniques--bilateral alar arch components individually positioned, then shaped and unified for symmetry, and finally positioned for rotation and projection--and (5) introducing an integrated set of surgical techniques and sequencing of tip surgery to achieve the objectives listed above in most primary and some secondary rhinoplasties. The concepts and techniques of this approach are based on the principle that preservation of structural integrity of alar complex elements (medial and lateral crural arch elements) preserves support and reduces the incidence of secondary deformities (kinking, buckling, discontinuity) that can result from shaping techniques which disrupt that integrity. If shaping and positioning of the tip can be achieved with reversible, nondestructive techniques, the need for placement of visible grafts (with their additional variables) is greatly reduced. Shaping and positioning can be performed incrementally and reversibly without jeopardizing structural integrity and support in the surgical process. Ten fresh cadaver dissections were utilized in the development of the surgical techniques. A total of 233 rhinoplasties (220 primary and 13 secondary) with 1 to 9 years of follow-up have been performed using this approach. Only two secondary procedures for tip deformity have been performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Septal Extension Grafts: A Method of Controlling Tip Projection Shape
Byrd, H. S., Andochick, S., Copit, S., & Walton, K. G. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199709001-00026 · Cited by 356
Nasal Tip Sutures Part II: The Interplays
Guyuron, B., & Behmand, R. A. (2003) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000076505.83375.74 · Cited by 177
“(1) The medial crura suture approximates the medial crura and strengthens the support of the tip.”
BackgroundRevision rhinoplasty: review of deformities, aetiology and treatment strategies
Vuyk, H. D., Watts, S. J., & Vindayak, B. (2000) · Clinical Otolaryngology and Allied Sciences · doi:10.1046/j.1365-2273.2000.00353.x · Cited by 50
Rhinoplasty with Advancing Age
Rohrich, R. J., & Hollier, L. H. (1996) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31118-4 · Cited by 25
Effects of Different Suture Materials on Cartilage Reshaping
Cagici, C. A., Cakmak, O., Bal, N., Yavuz, H., & Tuncer, I. (2008) · Archives of Facial Plastic Surgery · doi:10.1001/archfaci.10.2.124 · Cited by 17
Metadata
- Authors
- Tebbetts, J. B.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1994-07
- Volume
- 94
- Issue
- 1
- Pages
- 61-77
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1975173762
- Cited by
- 258
- References
- 0
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shaping and Positioning the Nasal Tip Without Structural Disruption: A New, Systematic Approach. https://app.cochat.ai/papers/10.1097/00006534-199407000-00006
- The paper
- Tebbetts, J. B. (1994). Shaping and Positioning the Nasal Tip Without Structural Disruption: A New, Systematic Approach. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199407000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.