Transplantation of Chondrocytes Utilizing a Polymer-Cell Construct to Produce Tissue-Engineered Cartilage in the Shape of a Human Ear
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
This study evaluates the feasibility of growing tissue-engineered cartilage in the shape of a human ear using chondrocytes seeded onto a synthetic biodegradable polymer fashioned in the shape of a 3-year-old child's auricle. A polymer template was formed in the shape of a human auricle using a nonwoven mesh of polyglycolic acid molded after being immersed in a 1% solution of polylactic acid. Each polyglycolic acid-polylactic acid template was seeded with chondrocytes isolated from bovine articular cartilage and then implanted into subcutaneous pockets on the dorsa of 10 athymic mice. The three-dimensional structure was well maintained after removal of an external stent that had been applied for 4 weeks. Specimens harvested 12 weeks after implantation and subjected to gross morphologic and histologic analysis demonstrated new cartilage formation. The overall geometry of the experimental specimens closely resembled the complex structure of the child's auricle. These findings demonstrate that polyglycolic acid-polylactic acid constructs can be fabricated in a very intricate configuration and seeded with chondrocytes to generate new cartilage that would be useful in plastic and reconstructive surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selective cell transplantation using bioabsorbable artificial polymers as matrices
Vacanti, J. P., Morse, M. A., Saltzman, W. M., Domb, A. J., Perez-Atayde, A., & Langer, R. (1988) · Journal of Pediatric Surgery · doi:10.1016/s0022-3468(88)80529-3 · Cited by 602
Self-citationSynthetic Polymers Seeded with Chondrocytes Provide a Template for New Cartilage Formation
Vacanti, C. A., Langer, R., Schloo, B., & Vacanti, J. P. (1991) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199111000-00001 · Cited by 547
Self-citationTOTAL RECONSTRUCTION OF THE EXTERNAL EAR
TANZER, R. C. (1959) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-195901000-00001 · Cited by 416
Auricular repair with autogenous rib cartilage grafts: two decades of experience with 600 cases.
Brent, B. (1992) · PubMed · Cited by 342
Auricular Repair with Autogenous Rib Cartilage Grafts: Two Decades of Experience with 600 Cases
Brent, B. (1992) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199209000-00001 · Cited by 334
Osseointegrated Alloplastic versus Autogenous Ear Reconstruction: Criteria for Treatment Selection
Wilkes, G. H., & Wolfaardt, J. F. (1994) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199404001-00011 · Cited by 129
Wellisz, T. (1993) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199304001-00009 · Cited by 108
Refinements in Pediatric Microtia Reconstruction
Eavey, R. D., & Ryan, D. P. (1996) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1996.01890180025008 · Cited by 26
Cited by
Bioactive glass in tissue engineering
Rahaman, M. N., Day, D. E., Sonny Bal, B., Fu, Q., Jung, S. B., Bonewald, L. F., & Tomsia, A. P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.03.016 · Cited by 1,794
Bone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering
Williams, J. M., Adewunmi, A., Schek, R. M., Flanagan, C. L., Krebsbach, P. H., Feinberg, S. E., Hollister, S. J., & Das, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.057 · Cited by 1,563
Scaffold-free vascular tissue engineering using bioprinting
Norotte, C., Marga, F. S., Niklason, L. E., & Forgacs, G. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.06.034 · Cited by 1,339
Department of Materials, U. O. O., Sachlos, E., & Czernuszka, J. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a03 · Cited by 1,303
Potential of Nanofiber Matrix as Tissue-Engineering Scaffolds
Ma, Z., Kotaki, M., Inai, R., & Ramakrishna, S. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.101 · Cited by 1,032
Metadata
- Authors
- Cao, Y., Vacanti, J. P., Paige, K. T., Upton, J., & Vacanti, C. A.
- Venue
- Plastic & Reconstructive Surgery
- Published
- 1997-08
- Volume
- 100
- Issue
- 2
- Pages
- 297-302
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2087735843
- Cited by
- 749
- References
- 8
- FWCI
- 15.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.