The DOI matches its Crossref record.
Tissue Engineered Neocartilage Using Plasma Derived Polymer Substrates and Chondrocytes
Abstract
This study demonstrates that fibrin monomers can be polymerized into moldable gels and used for the encapsulation of isolated chondrocytes. This biologically derived scaffold will maintain three-dimensional spatial support, allowing new tissue development in a subcutaneous space. Chondrocytes isolated from the glenohumeral and humeroradioulnar joints of a calf were combined with cyroprecipitate and polymerized with bovine thrombin to create a fibrin glue gel with a final cell density of 12.5 x 10(6) cells/ml. The polymer-chondrocyte constructs were implanted subcutaneously in 12 nude mice and incubated for 6 and 12 weeks in vivo. Histologic and biochemical analysis including deoxyribonucleic acid (DNA) and glycosaminoglycan quantitation confirmed the presence of actively proliferating chondrocytes with production of a well-formed cartilaginous matrix in the transplanted samples. Control specimens from 12 implantation sites consisting of chondrocytes alone or fibrin glue substrates did not demonstrate any gross or histologic evidence of neocartilage formation. Moldable autogenous fibrin glue polymer systems have a potential to serve as alternatives to current proprietary polymer systems used for tissue engineering cartilage as well as autogenous grafts and alloplastic materials used for facial skeletal and soft-tissue augmentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell Encapsulation in Biodegradable Hydrogels for Tissue Engineering Applications
Nicodemus, G. D., & Bryant, S. J. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0332 · Cited by 1,239
Fibrin: A versatile scaffold for tissue engineering applications
Ahmed, T. A. E., Dare, E. V., & Hincke, M. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0435 · Cited by 994
Polymeric biomaterials for tissue and organ regeneration
Seal, B. (2001) · Materials Science and Engineering: R: Reports · doi:10.1016/s0927-796x(01)00035-3 · Cited by 892
Controlled Degradation and Mechanical Behavior of Photopolymerized Hyaluronic Acid Networks
Burdick, J. A., Chung, C., Jia, X., Randolph, M. A., & Langer, R. (2005) · Biomacromolecules · doi:10.1021/bm049508a · Cited by 777
Self-citationDevelopment of fibrin derivatives for controlled release of heparin-binding growth factors
Sakiyama-Elbert, S. E., & Hubbell, J. A. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00221-7 · Cited by 565
Metadata
- Authors
- Sims, D. C., Butler, P. E. M., Cao, Y. L., Casanova, R., Randolph, M. A., Black, A., Vacanti, C. A., & Yaremchuk, M. J.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1998-05
- Volume
- 101
- Issue
- 6
- Pages
- 1580-1585
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2082687207
- Cited by
- 183
- References
- 0
- FWCI
- 8.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue Engineered Neocartilage Using Plasma Derived Polymer Substrates and Chondrocytes. https://app.cochat.ai/papers/10.1097/00006534-199805000-00022
- The paper
- Sims, D. C., Butler, P. E. M., Cao, Y. L., Casanova, R., Randolph, M. A., Black, A., Vacanti, C. A., & Yaremchuk, M. J. (1998). Tissue Engineered Neocartilage Using Plasma Derived Polymer Substrates and Chondrocytes. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199805000-00022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.