Safety Considerations and Fluid Resuscitation in Liposuction: An Analysis of 53 Consecutive Patients
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
There is no agreement as to appropriate fluid resuscitation in patients undergoing liposuction. This has assumed greater significance, as surgeons have undertaken larger volume aspirations (> or = 4 liters) and the potential complications of hypovolemia and fluid overload have materialized. This prospective study of 53 consecutive healthy patients undergoing liposuction using a superwet technique served to develop general guidelines for safe perioperative fluid management, especially in regard to large-volume aspirations. In this context, "aspirate" is defined as the total fat and fluid that is removed during liposuction. All patients were monitored using standard noninvasive hemodynamic monitoring. Thirty-six patients were monitored perioperatively with Foley catheters. The 53 patients underwent liposuction alone. We did not include patients who underwent concurrent aesthetic surgical procedures because our intention was to establish fluid administration guidelines for the liposuction patient. There were no significant complications in our series. The intraoperative fluid ratio, defined as (intravenous fluid + infiltrate)/aspirate, was 2.1 for the small-volume group and 1.4 for the large-volume group. These values were significantly different (p < .001, t test). Average urine output in the operating room and recovery room and on the floor was satisfactory (> 0.5 to 1 cc/kg/hr) and did not relate to volume aspirated (p = 0.21, 0.91, and 0.6, respectively, t test). Four patients who underwent "large-volume" aspirations (> or = 4 liters) had transient hypotension, which was immediately responsive to crystalloid fluid boluses in the first postoperative hours. All other patients required only maintenance intravenous crystalloid postoperatively until oral intake had been resumed. There were no statistically significant differences in postoperative fluid administration between the small- and large-volume groups. Ninety-three percent of patients were discharged within 24 hours of surgery. Our suggested guidelines for fluid resuscitation based on this retrospective study are as follows: (1) small volume (< 4 liters aspirated): maintenance fluid + subcutaneous wetting solution; (2) large volume (> or = 4 liters aspirated): maintenance fluid + subcutaneous wetting solution + 0.25 cc of intravenous crystalloid per cc of aspirate removed after 4 liters. This formula has since been used in the care of 94 patients who have undergone liposuction exclusively. All patients have had unremarkable hospital courses. These guidelines do not replace sound clinical judgment. Good communication between the surgeon and anesthesiologist is critical to optimal patient care and safety.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Tumescent Technique for Regional Anesthesia Permits Lidocaine Doses of 35 mg/kg for Liposuction
KLEIN, J. A. (1990) · The Journal of Dermatologic Surgery and Oncology · doi:10.1111/j.1524-4725.1990.tb03961.x · Cited by 672
Tumescent Technique for Local Anesthesia Improves Safety in Large-Volume Liposuction
Klein, J. A. (1993) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199311000-00014 · Cited by 475
The Tumescent Technique: Anesthesia and Modified Liposuction Technique
Klein, J. A. (1990) · Dermatologic Clinics · doi:10.1016/s0733-8635(18)30474-1 · Cited by 306
Tumescent Anesthesia with a Lidocaine Dose of 55 mg/kg Is Safe for Liposuction
OSTAD, A., KAGEYAMA, N., & MOY, R. L. (1996) · Dermatologic Surgery · doi:10.1111/j.1524-4725.1996.tb00634.x · Cited by 302
Liposuction Surgery Under Local Anesthesia: Limited Blood Loss and Minimal Lidocaine Absorption
LILLIS, P. J. (1988) · The Journal of Dermatologic Surgery and Oncology · doi:10.1111/j.1524-4725.1988.tb03472.x · Cited by 192
Extending the Role of Liposuction in Body Contouring with Ultrasound-Assisted Liposuction
Rohrich, R. J., Beran, S. J., Kenkel, J. M., Adams, W. P., & DiSpaltro, F. (1998) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199804040-00033 · Cited by 176
Self-citationThe Role of Subcutaneous Infiltration in Suction-Assisted Lipoplasty: A Review
Rohrich, R. J., Beran, S. J., & Fodòr, P. B. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199702000-00031 · Cited by 157
Self-citationLidocaine and Epinephrine Levels in Tumescent Technique Liposuction
Burk, R. W., Guzman-Stein, G., & Vásconez, L. O. (1996) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199606000-00009 · Cited by 142
Tumescent Liposuction Complicated by Pulmonary Edema
Gilliland, M. D., & Coates, N. R. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199701000-00032 · Cited by 126
Pitman, G. H., Aker, J. S., & Tripp, Z. D. (1996) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32560-8 · Cited by 106
Research works printed but not linked: 2
- Pitman, 1991, Perspect Plast Surg, 5, 79
- Ostad, 1996, Dermatol Surg, 22, 921
Cited by
Absence of an Effect of Liposuction on Insulin Action and Risk Factors for Coronary Heart Disease
Klein, S., Fontana, L., Young, V. L., Coggan, A. R., Kilo, C., Patterson, B. W., & Mohammed, B. S. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033179 · Cited by 917
A New Method for Aesthetic Reduction of Labia Minora (the Deepithelialized Reduction Labioplasty)
Choi, H. Y., Kim, K. T., & Laub, D. R. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200001000-00070 · Cited by 380
Training the Generation X Plastic Surgeon: Dispelling the Myths?
Rohrich, R. J. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200111000-00048 · Cited by 277
Self-citationA New Method for Aesthetic Reduction of Labia Minora (the Deepithelialized Reduction Labioplasty)
Choi, H. Y., & Kim, K. T. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200001000-00069 · Cited by 196
A Classification of Facial Wrinkles
Lemperle, G., Holmes, R. E., Cohen, S. R., & Lemperle, S. M. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200111000-00050 · Cited by 184
Rohrich, R. J., Reagan, B. J., Adams, W. P., Kenkel, J. M., & Beran, S. J. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200001000-00067 · Cited by 168
Self-citationPractice Advisory on Liposuction
Iverson, R. E., & Lynch, D. J. (2004) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000111591.62685.f8 · Cited by 163
Teitelbaum, S. A., Burns, J. L., Kubota, J., Matsuda, H., Otto, M. J., Shirakabe, Y., Suzuki, Y., & Brown, S. A. (2007) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000270840.98133.c8 · Cited by 143
“In addition, even when clinically well-tolerated, hemodynamic and metabolic changes occur in the immediate post-surgical days.(9-13) Ultrasound-assisted liposuction (UAL) accounted for 21% of liposuction procedures in 2005.”
Mirror, Mirror on the Wall: When the Postoperative Reflection Does Not Meet Patientsʼ Expectations
Rohrich, R. J. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200108000-00035 · Cited by 130
Self-citationUpdates and Advances in Liposuction
Stephan, P. J., & Kenkel, J. M. (2010) · Aesthetic Surgery Journal · doi:10.1177/1090820x10362728 · Cited by 99
Self-citationPower-Assisted Lipoplasty (PAL): A Clinical Pilot Study Comparing PAL to Traditional Lipoplasty (TL)
Fodor, P. B., & Vogt, P. A. (1999) · Aesthetic Plastic Surgery · doi:10.1007/s002669900305 · Cited by 89
The American Society for Aesthetic Plastic Surgery (ASAPS) Survey: Current Trends in Liposuction
Ahmad, J., Eaves, F. F., Rohrich, R. J., & Kenkel, J. M. (2011) · Aesthetic Surgery Journal · doi:10.1177/1090820x10395508 · Cited by 77
Self-citationIllouz, Y. G. (2006) · Clinics in Plastic Surgery · doi:10.1016/j.cps.2005.10.001 · Cited by 76
“Prophylactic fluid management before, during, and after the procedure is crucial [35].”
BackgroundAscher, B. (2010) · Aesthetic Surgery Journal · doi:10.1177/1090820x09360692 · Cited by 75
Rohrich, R. J., & Beran, S. J. (1999) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199909030-00033 · Cited by 75
Self-citationPerioperative Management of Cosmetic Liposuction
de Jong, R. H., & Grazer, F. M. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200104010-00022 · Cited by 74
Fluid Resuscitation in Liposuction: A Retrospective Review of 89 Consecutive Patients
Rohrich, R. J., Leedy, J. E., Swamy, R., Brown, S. A., & Coleman, J. E. (2006) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000201477.30002.ce · Cited by 72
“1 From that article, the following recommendations for fluid management in the liposuction patient were developed: (1) preoperative fluid deficits should be given at the discretion of the surgeon or anesthesiologist; (2) maintenance fluids should be administered throughout the operation, with additional fluid boluses…”
MethodSelf-citationAutologous fat grafting: Harvesting techniques
Fontes, T., Brandão, I., Negrão, R., Martins, M. J., & Monteiro, R. (2018) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2018.11.005 · Cited by 72
Abdominoplasty and Abdominal Wall Rehabilitation: A Comprehensive Approach
Ramirez, O. M. (2000) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200001000-00071 · Cited by 71
Lipoaspiration and Its Complications: A Safe Operation
Cárdenas-Camarena, L. (2003) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000081469.07342.f2 · Cited by 70
Comparative Lipoplasty Analysis of in Vivo-Treated Adipose Tissue
Rohrich, R. J., Morales, D. E., Krueger, J. E., Ansari, M., Ochoa, O., Robinson, J. B. D., & Beran, S. J. (2000) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200005000-00039 · Cited by 68
Self-citationEvidence-Based Patient Safety Advisory: Liposuction
Haeck, P. C., Swanson, J., GUTOWSKI, K. A., Basu, C. B., Wandel, A. G., Damitz, L., Reisman, N. R., & Baker, S. B. (2009) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3181b52fcd · Cited by 73
Patient Safety in the Office-Based Setting
Horton, J. B., Reece, E. M., Broughton, G., Janis, J. E., Thornton, J. F., & Rohrich, R. J. (2006) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000204796.65812.68 · Cited by 63
Self-citationRubin, P. J., Bierman, C., Rosow, C. E., Arthur, R. G., Chang, Y., Courtiss, E. H., & May, J. W. (1999) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199903000-00036 · Cited by 61
Optimizing Patient Outcomes and Safety With Liposuction
Mendez, B. M., Coleman, J. E., & Kenkel, J. M. (2018) · Aesthetic Surgery Journal · doi:10.1093/asj/sjy151 · Cited by 59
Self-citationMOC-PS(SM) CME Article: Liposuction
Iverson, R. E., & Pao, V. S. (2008) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000308480.33644.56 · Cited by 56
Chow, I., Alghoul, M. S., Khavanin, N., Hanwright, P. J., Mayer, K. E., Hume, K. M., Murphy, R. X., GUTOWSKI, K. A., & Kim, J. Y. S. (2015) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000001498 · Cited by 55
Advancement of the External Oblique Muscle Flap to Improve the Waistline: A Study in Cadavers
Nahas, F. X. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200108000-00044 · Cited by 56
Abdominal contour surgery: Treating all aesthetic units, including the mons pubis
Matarasso, A. (2001) · Aesthetic Surgery Journal · doi:10.1067/maj.2001.114789 · Cited by 53
MOC-PS(SM) CME Article: Patient Safety in the Office-Based Setting
Horton, J. B., Janis, J. E., & Rohrich, R. J. (2008) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e318183c118 · Cited by 53
Self-citationSafely Combining Abdominoplasty with Aggressive Abdominal Liposuction Based on Perforator Vessels
Smith, L. F., & Smith, L. F. (2015) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000001200 · Cited by 50
Safety of Large-Volume Liposuction in Aesthetic Surgery: A Systematic Review and Meta-Analysis
Kanapathy, M., Pacifico, M. D., Yassin, A. M., Bollen, E., & Mosahebi, A. (2020) · Aesthetic Surgery Journal · doi:10.1093/asj/sjaa338 · Cited by 50
Liposuction: Anaesthesia challenges
Sood, J., Jayaraman, L., & Sethi, N. (2011) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.82652 · Cited by 44
“With this fluid management strategy, the patients appeared to be slightly overhydrated.[45]”
Karmo, F. R., Milan, M. F., & Silbergleit, A. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200107000-00039 · Cited by 44
Ultrasound‐assisted lipoplasty
Cooter, R. D., Babidge, W., Mutimer, K. L. A., Wickham, P., ROBINSON, D. H., Kiroff, G., Chapman, A., & Maddern, G. J. (2001) · ANZ Journal of Surgery · doi:10.1046/j.1440-1622.2001.02108.x · Cited by 39
An Update on the Role of Subcutaneous Infiltration in Suction-Assisted Lipoplasty
Rohrich, R. J., Kenkel, J. M., Janis, J. E., Beran, S. J., & Fodor, P. B. (2003) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000039396.69495.c5 · Cited by 37
Self-citationUpdate on Liposuction: What All Plastic Surgeons Should Know
Beidas, O. E., & Gusenoff, J. A. (2021) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000007419 · Cited by 35
When One Liter Does Not Equal 1000 Milliliters: Implications for the Tumescent Technique
Coleman, P. W., Flynn, T. C., & Coleman, K. (2000) · Dermatologic Surgery · doi:10.1046/j.1524-4725.2000.0260111024.x · Cited by 33
Impact of Large-Volume Liposuction on Serum Lipids in Orientals: A Pilot Study
Hong, Y. G., Kim, H. T., Seo, S. W., Chang, C. H., Rhee, E., & Lee, W. (2006) · Aesthetic Plastic Surgery · doi:10.1007/s00266-005-0010-7 · Cited by 38
“Although many scientific publications and clinical reports on large-volume liposuction are available [4,5,18,27,32], the physiologic consequences of this procedure are not well documented.”
BackgroundTalmor, M., Fahey, T. J., Wise, J. B., Hoffman, L. A., & Barie, P. S. (2000) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200005000-00053 · Cited by 28
Absence of an effect of liposuction on insulin action and risk factors for coronary heart disease
Klein, S., Fontana, L., & Young, V. L. (2004) · ACC Current Journal Review · doi:10.1016/j.accreview.2004.07.105 · Cited by 29
Jin, S., Yang, Z., Han, X., & Li, F. (2020) · Aesthetic Surgery Journal · doi:10.1093/asj/sjaa170 · Cited by 25
Lozinski, A., & Huq, N. S. (2013) · Clinics in Plastic Surgery · doi:10.1016/j.cps.2013.07.006 · Cited by 25
Perioperative Considerations for Patient Safety During Cosmetic Surgery – Preventing Complications
Ellsworth, W. A., Basu, C. B., & Iverson, R. E. (2009) · Plastic Surgery · doi:10.1177/229255030901700106 · Cited by 25
“If large volume liposuction is to be performed alone, the surgeon should give serious consideration to removing lidocaine from the tumescence after 4 L to avoid toxicity (31).”
BackgroundLidocaine In Ultrasound-Assisted Lipoplasty
Matarasso, A. (1999) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32636-5 · Cited by 25
Heating Infiltration Solutions Used in Tumescent Liposuction: Minimizing Surgical Risk
Robles-Cervantes, J. A., Mart??nez-Molina, R., & Cárdenas-Camarena, L. (2005) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000178790.99010.59 · Cited by 24
Perioperative considerations for patient safety during cosmetic surgery - preventing complications.
Ellsworth, W. A., Basu, C. B., & Iverson, R. E. (2009) · PubMed Central · Cited by 23
Safety and benefits of large-volume liposuction: a single center experience
Saleh, Y., El-Oteify, M., Farghaly, A.-E. A.-E., Tohamy, A., & Abd-Elsayed, A. A. (2009) · International Archives of Medicine · doi:10.1186/1755-7682-2-4 · Cited by 25
“• Pressure garment applied for 6 weeks [8].”
BackgroundOperative Behandlung des Lipödems
Ghods, M., & Kruppa, P. (2018) · Handchirurgie · Mikrochirurgie · Plastische Chirurgie · doi:10.1055/a-0767-6808 · Cited by 20
Danilla, S., Fontbona, M., de Valdés, V. D., Dagnino, B., Sorolla, J. P., Israel, G., Searle, S. V., B, H. N., & Cabello, R. (2013) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3182958b20 · Cited by 19
Lipoplasty Claims Experience of U.S. Insurance Companies
Bruner, J. G., & de Jong, R. H. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200104150-00030 · Cited by 19
Liposuction and Lipoinjection Treatment for Congenital and Acquired Lipodystrophies in Children
Giugliano, C., Benítez, S., Wisnia, P., Sorolla, J. P., Acosta, S., V, & Andrades, P. R. (2009) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3181a80539 · Cited by 18
Basile, A. R., Fernandes, F. G., Basile, V. V., & Basile, F. V. (2006) · Aesthetic Plastic Surgery · doi:10.1007/s00266-006-0118-4 · Cited by 18
“Using the formulas in Table 1 as guidelines, the intraoperative fluid ratio, defined as the ratio of the intraoperative intravenous fluid plus the subcutaneous infiltrate to the total aspirate [24], ranged from 0.”
BackgroundMethodResultInfluentialLarge-Volume Liposuction and Prevention of Type 2 Diabetes: A Preliminary Report
Narsete, T. A., Narsete, M. P., Buckspan, R., & Ersek, R. A. (2011) · Aesthetic Plastic Surgery · doi:10.1007/s00266-011-9798-5 · Cited by 18
“The safety of fluid replacement has been published previously [ 10 ].”
BackgroundRohrich, R. J., Raniere, J., Kenkel, J. M., & Beran, S. J. (1999) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32618-3 · Cited by 17
Self-citationAvoiding unfavourable outcomes in liposuction
Khanna, A., & Filobbos, G. (2013) · Indian Journal of Plastic Surgery · doi:10.4103/0970-0358.118618 · Cited by 17
“Tumescent liposuction has various surgical and anaesthetic advantages, but it is prudent to consider the possible complications of fluid overload such as pulmonary oedema, especially if the patient is having intravenous fluids simultaneously.[13]”
BackgroundPituitary Apoplexy Occurring During Large Volume Liposuction Surgery
Cohen, A., Kishore, K., Wolansky, L. J., & Frohman, L. (2004) · Journal of Neuro-Ophthalmology · doi:10.1097/00041327-200403000-00007 · Cited by 16
“A recommended formula for fluid replacement during this procedure has been established as a guideline (16).”
BackgroundCárdenas-Camarena, L., rdenas, A. C., & Barajas, D. F. (2001) · Annals of Plastic Surgery · doi:10.1097/00000637-200103000-00015 · Cited by 15
Choudry, U. H., Hýža, P., Lane, J., & Petty, P. M. (2008) · Annals of Plastic Surgery · doi:10.1097/sap.0b013e31815bf341 · Cited by 19
Menick, F. J. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200108000-00034 · Cited by 23
Wang, G., Cao, W., Li, S., Liu, L., & Jiang, Z. (2013) · Annals of Plastic Surgery · doi:10.1097/sap.0b013e3182933de7 · Cited by 14
“It is estimated that 50% to 70% of the residual f luid volume is left behind when a liposuction procedure is completed.(19) This residual volume represents f luid available for autoresuscitation by hypodermoclysis.”
BackgroundBody Mass Index: Risk Predictor for Cosmetic Day Surgery
de Jong, R. H. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200108000-00045 · Cited by 14
Mega-Dose Lidocaine Dangers Seen in “Tumescent” Liposuction
de Jong, R. H. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009921805662 · Cited by 14
“Thus, conventional approximations to intraoperative IV £uid replacement no longer hold, and hydration status may need to be monitored with a bladder catheter whenever large-volume (more than 4 or 5 liters) liposuction is proposed [8].”
MethodPlastic Surgery: Understanding Abdominoplasty and Liposuction
Logan, J. M., & Broughton, G. (2008) · AORN Journal · doi:10.1016/j.aorn.2008.07.018 · Cited by 12
Fluid management in extensive liposuction
Wang, G., Cao, W., & Zhao, T. (2018) · Medicine · doi:10.1097/md.0000000000012655 · Cited by 12
“Intraoperative fluid ratio is the sum of the superwet infiltration volume plus the intraoperative IV fluid volume divided by the volume of aspiration.([6]) However, the patients appeared to be slightly overhydrated under this fluid management strategy.”
BackgroundResultSafe Limits for Aspirate Volume Under Wet Liposuction
Cantarelli, J., & de Godoy, M. F. (2009) · Obesity Surgery · doi:10.1007/s11695-009-9958-8 · Cited by 11
“Blood volume replacement [16–19] starts intraoperatively and causes hemodilution.”
BackgroundOptimal Use of Local Anesthetics and Tumescence
Gordley, K. P., & Basu, C. B. (2006) · Seminars in Plastic Surgery · doi:10.1055/s-2006-951579 · Cited by 11
“This occurs in the setting of vasodilating effects of general anesthesia.(24) Such stresses are well tolerated by a young healthy heart but must be respected in patients with comorbidities.”
BackgroundInfluentialLipoplasty in the Overweight Patient
Cruz, E. D. L. (2023) · Clinics in Plastic Surgery · doi:10.1016/j.cps.2023.06.010 · Cited by 10
Ibarra, P., Arango, J., Bayter, J. E., Castro, J., Cortés, J., Lascano, M., & Flórez, E. L. (2009) · Colombian Journal of Anesthesiology · doi:10.1016/s0120-3347(09)74012-2 · Cited by 10
Liposuction Anesthesia Techniques
Regatieri, F. L. F., & Mosquera, M. S. (2006) · Clinics in Plastic Surgery · doi:10.1016/j.cps.2005.08.003 · Cited by 10
“Fluid replacement is one of the most important aspects in the intraoperative handling of lipoplasty [26,27].”
BackgroundVivek, K., Amiti, S., Shivshankar, S., & Choudhary, L. (2014) · Indian Journal of Plastic Surgery · doi:10.4103/0970-0358.146604 · Cited by 8
“[1] Profound haemodynamic and metabolic alterations can accompany large volume liposuction.[2-5]”
BackgroundMethodVila, H., Desai, M. S., & Miguel, R. V. (2008) · Springer eBooks · doi:10.1007/978-0-387-73329-6_11 · Cited by 8
Ultrasound-Assisted Lipoplasty
Kenkel, J. M., Gingrass, M. K., & Rohrich, R. J. (1999) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32607-9 · Cited by 8
Self-citationAl-Dujaili, Z., Karcher, C., Henry, M., & Sadick, N. S. (2018) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2017.07.025 · Cited by 8
A Combined Program of Small-volume Liposuction, Endermologie, and Nutrition: A Logical Alternative
Dabb, R. W. (1999) · Aesthetic Surgery Journal · doi:10.1053/aq.1999.v19.101747001 · Cited by 7
Aslani, A., Waked, K., & Kuenlen, A. (2022) · Aesthetic Surgery Journal · doi:10.1093/asj/sjac349 · Cited by 6
Rohrich, R. J., & Muzaffar, A. R. (2000) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200005000-00054 · Cited by 6
Self-citationAnesthesia considerations in large-volume lipoplasty
THOMAS, M., Bhorkar, N., D’Silva, J. A., MENON, H., & Bandekar, N. (2007) · Aesthetic Surgery Journal · doi:10.1016/j.asj.2007.08.006 · Cited by 6
Rubin, P. J., Bierman, C., Rosow, C. E., Arthur, R. G., Courtiss, E. H., & May, J. W. (1999) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199903000-00038 · Cited by 5
Anesthesia Management for Large-Volume Liposuction
Granados-Tinajero, S. O., Vásquez, C. B., Cárdenas-Maytorena, C., & Contreras-López, M. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.83630 · Cited by 5
Hemodynamic Changes and Fluid Shifts After Large-Volume Fluid Infiltration
Özmen, S., Kusza, K., Ulusal, B. G., Pryor, L. S., Siemionow, M., & Zins, J. E. (2009) · Annals of Plastic Surgery · doi:10.1097/sap.0b013e31819adfc5 · Cited by 5
“As a result of the pharmacological properties of tumescent solution and the hydrostatic pressure created by a large amount of infiltrate, intraoperative and postoperative fluid shifts are complex.(9,11) Few studies have directly investigated these fluid shifts.”
BackgroundKarmo, F. R., Milan, M. F., & Silbergleit, A. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200107000-00040 · Cited by 5
Evans, G. R. D., Scholz, T., & Brandt, K. E. (2015) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000001335 · Cited by 5
Acute pulmonary edema following liposuction due to heart failure and atypical pneumonia
Wollina, U., Graf, A., & Hanisch, V. (2015) · Wiener Medizinische Wochenschrift · doi:10.1007/s10354-014-0333-6 · Cited by 5
Gordon, H. (2011) · InTech eBooks · doi:10.5772/21355 · Cited by 4
Perioperative considerations for patient safety during cosmetic surgery – preventing complications
Ellsworth, W. A., Basu, C. B., & Iverson, R. E. (2009) · Plastic Surgery · doi:10.4172/plastic-surgery.1000595 · Cited by 4
Hypotension in the PACU: An algorithmic approach
Cowling, G. E., & Haas, R. E. (2002) · Journal of PeriAnesthesia Nursing · doi:10.1053/jpan.2002.33208 · Cited by 5
Chow, I., Alghoul, M. S., Khavanin, N., Hanwright, P. J., Mayer, K. E., Hume, K. M., Murphy, R. X., GUTOWSKI, K. A., & Kim, J. Y. S. (2016) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000480035.97330.6b · Cited by 4
Sahin, T., Kavaklı, A. S., Aydinli, Y., Şahin, N. K., & Hepsev, A. (2026) · Aesthetic Plastic Surgery · doi:10.1007/s00266-026-05991-0 · Cited by 3
“The literature emphasizes the effect of team experience and standardization in reducing complications [9, 10].”
Liposuction Infiltration: The Quito Formula – a New Approach Based On An Old Concept
Galárraga, I. M. C. (2011) · Plastic Surgery · doi:10.1177/229255031101900105 · Cited by 3
“In experienced hands, large-volume liposuction is a safe procedure; therefore, it should not be condemned (54-58).”
BackgroundManejo de líquidos, lidocaína y epinefrina en liposucción. La forma correcta
Marín, J. E. B. (2014) · Colombian Journal of Anesthesiology · doi:10.1016/j.rca.2014.09.007 · Cited by 3
CIRUGÍA PLÁSTICA Y SUS COMPLICACIONES: ¿EN QUÉ DEBEMOS FIJARNOS?
Claudio Nazar, J., Maximiliano Zamora, H., Eduardo Vega, P., de la Cuadra-Fontaine, J. C., Susana Searle, F., & Bruno Dagnino, U. (2014) · Revista de Cirugía · doi:10.4067/s0718-40262014000600016 · Cited by 3
Safety, tolerability, and efficacy evaluation of the SlimME device for circumference reduction
Ferrando, G. (2018) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22796 · Cited by 3
Fettabsaugungen im ambulanten Setting
Güven, A., Schaffartzik, W., & Allert, S. (2021) · Handchirurgie · Mikrochirurgie · Plastische Chirurgie · doi:10.1055/a-1333-2696 · Cited by 3
“2006 mit dem selbigen Vorgehen ab einer Menge von 5000 ml [24, 12].”
Large-Volume Liposuction: A Review of 631 Consecutive Cases over 12 Years
Commons, G. W., Halperin, B. D., & Chang, C. C. (2001) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200111000-00052 · Cited by 3
Anesthesia for Plastic Surgery Procedures
Whizar-Lugo, V. M., & Cárdenas-Maytorena, A. C. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.81284 · Cited by 2
“[60] recommended the following scheme: (a) liposuction of small volumes (<4 L of aspirate) = maintenance liquids + the volume of the injected subcutaneous solution and Figure 3.”
MethodChen, L., Chang, K., Chen, Y., Xu, Z., & Shen, W. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.778230 · Cited by 2
Outpatient-Based High-Volume Liposuction: A Retrospective Review of 310 Consecutive Patients
Golpanian, S., Rahal, G. A., & Rahal, W. (2023) · Aesthetic Surgery Journal · doi:10.1093/asj/sjad164 · Cited by 2
Complicaciones asociadas a liposucción: más allá de los titulares de prensa
Garcés, C. E. R. (2000) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 2
Current trends of liposuction in India: Survey and Analysis
Methil, B. (2015) · Indian Journal of Plastic Surgery · doi:10.4103/0970-0358.173122 · Cited by 2
“in 1998 (updated in 2006),[21,22] the following formula can help in fluid management for these patients.”
Background
Metadata
- Authors
- Trott, S. A., Beran, S. J., Rohrich, R. J., Kenkel, J. M., Adams, W. P., & Klein, K. W.
- Affiliations
- The University of Texas Southwestern Medical Center (US)
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1998-11
- Volume
- 102
- Issue
- 6
- Pages
- 2220-2229
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1989159097
- Semantic Scholar
- bc5c8e77a4224b470708a7837bc3d64fede9200e
- Cited by
- 141
- References
- 27
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 1 · 2023: 4 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 3 · 2018: 7 · 2017: 1 · 2016: 2 · 2015: 8 · 2014: 4 · 2013: 4 · 2012: 1
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Plastic & Reconstructive Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Body Contouring and Surgery
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Surgery › Bariatric Surgery and Outcomes
- Keywords
- liposuction, fluid resuscitation, perioperative fluid management, hypovolemia, fluid overload, urine output, hypotension, discharge criteria, noninvasive hemodynamic monitoring, postoperative complications
- MeSH terms
- Adolescent, Adult, Aged, Analgesics, Female, Humans, Hypotension, Lidocaine, Male, Middle Aged, Monitoring, Physiologic, Postoperative Care, Prospective Studies, Safety, Water-Electrolyte Balance, Lipectomy, Perioperative Care
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.