Safety Considerations and Fluid Resuscitation in Liposuction: An Analysis of 53 Consecutive Patients
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
There is no agreement as to appropriate fluid resuscitation in patients undergoing liposuction. This has assumed greater significance, as surgeons have undertaken larger volume aspirations (> or = 4 liters) and the potential complications of hypovolemia and fluid overload have materialized. This prospective study of 53 consecutive healthy patients undergoing liposuction using a superwet technique served to develop general guidelines for safe perioperative fluid management, especially in regard to large-volume aspirations. In this context, "aspirate" is defined as the total fat and fluid that is removed during liposuction. All patients were monitored using standard noninvasive hemodynamic monitoring. Thirty-six patients were monitored perioperatively with Foley catheters. The 53 patients underwent liposuction alone. We did not include patients who underwent concurrent aesthetic surgical procedures because our intention was to establish fluid administration guidelines for the liposuction patient. There were no significant complications in our series. The intraoperative fluid ratio, defined as (intravenous fluid + infiltrate)/aspirate, was 2.1 for the small-volume group and 1.4 for the large-volume group. These values were significantly different (p < .001, t test). Average urine output in the operating room and recovery room and on the floor was satisfactory (> 0.5 to 1 cc/kg/hr) and did not relate to volume aspirated (p = 0.21, 0.91, and 0.6, respectively, t test). Four patients who underwent "large-volume" aspirations (> or = 4 liters) had transient hypotension, which was immediately responsive to crystalloid fluid boluses in the first postoperative hours. All other patients required only maintenance intravenous crystalloid postoperatively until oral intake had been resumed. There were no statistically significant differences in postoperative fluid administration between the small- and large-volume groups. Ninety-three percent of patients were discharged within 24 hours of surgery. Our suggested guidelines for fluid resuscitation based on this retrospective study are as follows: (1) small volume (< 4 liters aspirated): maintenance fluid + subcutaneous wetting solution; (2) large volume (> or = 4 liters aspirated): maintenance fluid + subcutaneous wetting solution + 0.25 cc of intravenous crystalloid per cc of aspirate removed after 4 liters. This formula has since been used in the care of 94 patients who have undergone liposuction exclusively. All patients have had unremarkable hospital courses. These guidelines do not replace sound clinical judgment. Good communication between the surgeon and anesthesiologist is critical to optimal patient care and safety.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Tumescent Technique for Regional Anesthesia Permits Lidocaine Doses of 35 mg/kg for Liposuction
KLEIN, J. A. (1990) · The Journal of Dermatologic Surgery and Oncology · doi:10.1111/j.1524-4725.1990.tb03961.x · Cited by 672
Tumescent Technique for Local Anesthesia Improves Safety in Large-Volume Liposuction
Klein, J. A. (1993) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199311000-00014 · Cited by 475
The Tumescent Technique: Anesthesia and Modified Liposuction Technique
Klein, J. A. (1990) · Dermatologic Clinics · doi:10.1016/s0733-8635(18)30474-1 · Cited by 306
Tumescent Anesthesia with a Lidocaine Dose of 55 mg/kg Is Safe for Liposuction
OSTAD, A., KAGEYAMA, N., & MOY, R. L. (1996) · Dermatologic Surgery · doi:10.1111/j.1524-4725.1996.tb00634.x · Cited by 302
Liposuction Surgery Under Local Anesthesia: Limited Blood Loss and Minimal Lidocaine Absorption
LILLIS, P. J. (1988) · The Journal of Dermatologic Surgery and Oncology · doi:10.1111/j.1524-4725.1988.tb03472.x · Cited by 192
Extending the Role of Liposuction in Body Contouring with Ultrasound-Assisted Liposuction
Rohrich, R. J., Beran, S. J., Kenkel, J. M., Adams, W. P., & DiSpaltro, F. (1998) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199804040-00033 · Cited by 176
Self-citationThe Role of Subcutaneous Infiltration in Suction-Assisted Lipoplasty: A Review
Rohrich, R. J., Beran, S. J., & Fodòr, P. B. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199702000-00031 · Cited by 157
Self-citationLidocaine and Epinephrine Levels in Tumescent Technique Liposuction
Burk, R. W., Guzman-Stein, G., & Vásconez, L. O. (1996) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199606000-00009 · Cited by 142
Tumescent Liposuction Complicated by Pulmonary Edema
Gilliland, M. D., & Coates, N. R. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199701000-00032 · Cited by 126
Pitman, G. H., Aker, J. S., & Tripp, Z. D. (1996) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32560-8 · Cited by 106
Read, M. S., & Vaughan, R. S. (1991) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1991.tb03354.x · Cited by 104
Blood loss during liposuction using the tumescent technique
Samdal, F., Amland, P. F., & Bugge, J. F. (1994) · Aesthetic Plastic Surgery · doi:10.1007/bf00454476 · Cited by 91
Large-Volume Suction Lipectomy: An Analysis of 108 Patients
Courtiss, E. H., Choucair, R. J., & Donelan, M. B. (1992) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199206000-00012 · Cited by 91
Editorial. Wetting solutions in aspirative lipoplasty: A plea for safety in liposuction
Fodòr, P. B. (1995) · Aesthetic Plastic Surgery · doi:10.1007/bf00451665 · Cited by 83
The Tumescent Technique for Liposuction Surgery
Lillis, P. J. (1990) · Dermatologic Clinics · doi:10.1016/s0733-8635(18)30475-3 · Cited by 83
HOW LONG SHOULD PATIENTS FAST BEFORE SURGERY ? TIME FOR NEW GUIDELINES
STRUNIN, L. (1993) · British Journal of Anaesthesia · doi:10.1093/bja/70.1.1 · Cited by 70
Clayton, D. N., Clayton, J. N., Lindley, T. S., & Clayton, J. L. (1989) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31344-4 · Cited by 63
Tumescent Technique for Local Anesthesia Improves Safety in Large-Volume Liposuction
Klein, J. A., & Pitman, G. H. (1993) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199311000-00015 · Cited by 59
Complications of the Tumescent Formula For Liposuction
Grazer, F. M., & Meister, F. L. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199712000-00040 · Cited by 51
Blood and Fluid Replacement for Lipoplasty Procedures
Retter, G. P. (1989) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31338-9 · Cited by 45
Improved Results with Closed Facial Suction
Hetter, G. P. (1989) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31346-8 · Cited by 39
Safe Suction: Fluid Replacement and Blood Loss Parameters
Pitman, G. H., & Holzer, J. A. (1991) · Seminars in Plastic Surgery · doi:10.1055/s-2008-1080416 · Cited by 18
Factors contributing to adverse effects of the tumescent technique*
Grazer, F. M., & Meister, F. L. (1997) · Aesthetic Surgery Journal · doi:10.1016/s1090-820x(97)80060-x · Cited by 17
CHRISMAN, B. B., & Coleman, W. P. (1988) · The Journal of Dermatologic Surgery and Oncology · doi:10.1111/j.1524-4725.1988.tb03466.x · Cited by 17
Tumescent liposuction: Operative technique
Pitman, G. H. (1996) · Operative Techniques in Plastic and Reconstructive Surgery · doi:10.1016/s1071-0949(96)80002-3 · Cited by 5
Pitman, G. H. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199702000-00034 · Cited by 4
Parenteral fluid administration beneath the fascia lata
Finley, R. K., Shaffer, J. M., & Altenberg, A. R. (1944) · The American Journal of Surgery · doi:10.1016/s0002-9610(44)90370-3 · Cited by 3
Research works printed but not linked: 2
- Pitman, 1991, Perspect Plast Surg, 5, 79
- Ostad, 1996, Dermatol Surg, 22, 921
Cited by
Absence of an Effect of Liposuction on Insulin Action and Risk Factors for Coronary Heart Disease
Klein, S., Fontana, L., Young, V. L., Coggan, A. R., Kilo, C., Patterson, B. W., & Mohammed, B. S. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033179 · Cited by 917
A New Method for Aesthetic Reduction of Labia Minora (the Deepithelialized Reduction Labioplasty)
Choi, H. Y., Kim, K. T., & Laub, D. R. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200001000-00070 · Cited by 380
Training the Generation X Plastic Surgeon: Dispelling the Myths?
Rohrich, R. J. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200111000-00048 · Cited by 277
Self-citationA New Method for Aesthetic Reduction of Labia Minora (the Deepithelialized Reduction Labioplasty)
Choi, H. Y., & Kim, K. T. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200001000-00069 · Cited by 196
A Classification of Facial Wrinkles
Lemperle, G., Holmes, R. E., Cohen, S. R., & Lemperle, S. M. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200111000-00050 · Cited by 184
Metadata
- Authors
- Trott, S. A., Beran, S. J., Rohrich, R. J., Kenkel, J. M., Adams, W. P., & Klein, K. W.
- Affiliations
- The University of Texas Southwestern Medical Center (US)
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1998-11
- Volume
- 102
- Issue
- 6
- Pages
- 2220-2229
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1989159097
- Semantic Scholar
- bc5c8e77a4224b470708a7837bc3d64fede9200e
- Cited by
- 141
- References
- 27
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 1 · 2023: 4 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 3 · 2018: 7 · 2017: 1 · 2016: 2 · 2015: 8 · 2014: 4 · 2013: 4 · 2012: 1
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Plastic & Reconstructive Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Body Contouring and Surgery
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Surgery › Bariatric Surgery and Outcomes
- Keywords
- liposuction, fluid resuscitation, perioperative fluid management, hypovolemia, fluid overload, urine output, hypotension, discharge criteria, noninvasive hemodynamic monitoring, postoperative complications
- MeSH terms
- Adolescent, Adult, Aged, Analgesics, Female, Humans, Hypotension, Lidocaine, Male, Middle Aged, Monitoring, Physiologic, Postoperative Care, Prospective Studies, Safety, Water-Electrolyte Balance, Lipectomy, Perioperative Care
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.