A New Method for Aesthetic Reduction of Labia Minora (the Deepithelialized Reduction Labioplasty)
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Standard abdominoplasty techniques involve a low horizontal or W skin excision, muscle plication, and umbilical transposition. Newer techniques include suction-assisted lipectomy, the use of high lateral tension with fascial suspension, and external oblique muscle advancement. The author has modified these traditional procedures and added new techniques to improve the aesthetic and functional results of the abdominoplasty procedure. This modification provides a comprehensive approach to abdominal wall aesthetic improvement and rehabilitation. The comprehensive approach described includes four components: the "U-M dermolipectomy," "V umbilicoplasty," the rectus abdominis "myofascial release," and suction-assisted lipectomy. The patient is marked while standing for areas of suction lipectomy and undermining. The lower incision is designed as an open U with the lateral limbs placed inside the bikini line. The upper incision is a lazy M with the higher peaks located at the level of the flanks. Subcutaneous hydration is achieved to perform suction along the flanks, waistline, and iliac areas. Gentle suction of the flaps is also performed. The umbilicus is cored out in a heart shape. The flaps within the U-M marks are excised, and the undermining is performed to the xiphoid and costal margins. The rectus diastasis is marked, and the anterior rectus fascia is incised at the junction of the medial third with the central third of the width of the rectus sheath. Horizontal figure-eight plication sutures by using the lateral fascial edge enable easier infolding of the central tissue. The new recipient of the umbilicus is made by an incision in a V shape on the abdominal flap. The umbilicus is telescoped, and the triangular flap of the abdomen is sutured to the triangular defect of the umbilicus. Skin flap fixation to the umbilicus relieves tension in the lower portion of the flap. The upper skin flap, which is cut in an M manner, provides lateral tension and matches the length of the lower flap. A standard fascial suspension is used and closure is performed in layers. The techniques described here are intertwined procedures. Each facilitates the accomplishment of the other procedure, and they complement each other. They all attain the 12 objectives of the abdominoplasty described. These combined techniques have been used in 104 patients in a period of 11 years. Complications were minimal and easily manageable, except for one patient who required excision of a pseudobursa and retightening of the lower quadrants of the abdominal wall musculature to correct extreme lordosis. A comprehensive approach for the treatment of complex abdominal wall aesthetic and functional defects is presented. These require thoughtful integration of the four components mentioned. This approach has allowed predictable, reproducible, and aesthetically pleasing results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
“Components Separation” Method for Closure of Abdominal-Wall Defects: An Anatomic and Clinical Study
Ramirez, O. M., Ruas, E., & Dellon, A. L. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199009000-00023 · Cited by 1,374
Tumescent Technique for Regional Anesthesia Permits Lidocaine Doses of 35 mg/kg for Liposuction
KLEIN, J. A. (1990) · The Journal of Dermatologic Surgery and Oncology · doi:10.1111/j.1524-4725.1990.tb03961.x · Cited by 672
Tumescent Anesthesia with a Lidocaine Dose of 55 mg/kg Is Safe for Liposuction
OSTAD, A., KAGEYAMA, N., & MOY, R. L. (1996) · Dermatologic Surgery · doi:10.1111/j.1524-4725.1996.tb00634.x · Cited by 302
Safety of Tumescent Liposuction in 15,336 Patients: National Survey Results
HANKE, W. C., BERNSTEIN, G., & BULLOCK, S. (1995) · Dermatologic Surgery · doi:10.1111/j.1524-4725.1995.tb00213.x · Cited by 269
Lidocaine and Epinephrine Levels in Tumescent Technique Liposuction
Burk, R. W., Guzman-Stein, G., & Vásconez, L. O. (1996) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199606000-00009 · Cited by 142
Safety Considerations and Fluid Resuscitation in Liposuction: An Analysis of 53 Consecutive Patients
Trott, S. A., Beran, S. J., Rohrich, R. J., Kenkel, J. M., Adams, W. P., & Klein, K. W. (1998) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199811000-00063 · Cited by 141
Samdal, F., Amland, P. F., & Bugge, J. F. (1994) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199405000-00017 · Cited by 113
Contouring The Hip and the Abdomen
Baroudi, R., & Ferreira, C. A. A. (1996) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32556-6 · Cited by 47 · cited 4×
“(2) The final closure finishes within the abdominal wall aesthetic units and follows a parallel line to a “french-cut” bikini.”
BackgroundMethodInfluential
Cited by
Female genital appearance: ‘normality’ unfolds
Lloyd, J., Crouch, N. S., Minto, C. L., Liao, L., & Creighton, S. M. (2005) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2004.00517.x · Cited by 431
Female Genital Cosmetic and Plastic Surgery: A Review
Goodman, M. P. (2011) · The Journal of Sexual Medicine · doi:10.1111/j.1743-6109.2011.02254.x · Cited by 183
Metadata
- Authors
- Choi, H. Y., & Kim, K. T.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2000-01
- Volume
- 105
- Issue
- 1
- Pages
- 419-422
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2066057740
- Cited by
- 196
- References
- 8
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.