Porous Polyethylene Implants in Orbital Floor Reconstruction
The DOI matches its Crossref record.
Abstract
The purpose of this article is to present the authors' experience with the use of porous polyethylene ultrathin sheets for orbital floor reconstruction. Thirty-two patients with orbital floor fractures were treated with porous polyethylene ultrathin sheets. Sixteen cases corresponded to orbitozygomatic fractures, 11 cases corresponded to pure orbital floor fractures, and five corresponded to panfacial fractures. The subciliary approach was used in 15 patients and the transconjunctival approach in nine; another three patients were operated on through a preexisting eyebrow wound, two were operated on with a subtarsal approach, two were operated on through an eyebrow extension of a facial wound, and one patient was operated on through the facial wound. Intraoperatively, all patients received a prophylactic dose of intravenous antibiotics. Postoperatively, 24 patients received amoxicillin clavulanate for 5 to 7 days, two patients received clindamycin, and six patients received no antibiotics. Enophthalmos was corrected in 15 of 24 patients (62.5 percent), and hypoglobus in nine of 11 (82 percent). Diplopia was resolved in 25 of 28 patients (89.3 percent) with preoperative impairment. Extrinsic eye movement impairment was resolved in 25 of 27 patients (92.6 percent). A preoperative visual acuity deficit was present in four patients (12.5 percent) and was resolved in one (from 20/100 to 20/20). Visual acuity improved in one patient (from 20/60 to 20/30). In the other two patients, visual acuity remained altered (from 20/30 to 20/30). One patient (3.1 percent) suffered blindness induced by surgery. Nine of 26 patients (34.6 percent) had residual infraorbital nerve hypesthesia and five (19.2 percent) had residual paresthesias. Postoperatively, epiphora was present in six patients (18.8 percent) and ectropion in five (15.6 percent). Although there was no statistical significance between the surgical approach and the presence of epiphora (p = 0.211) and ectropion (p = 0.422), patients who were treated using the transconjunctival approach suffered reduced ectropion (0 percent) compared with patients treated using the subciliary approach (20 percent). However, patients treated using the transconjunctival approach suffered increased epiphora (22.2 percent) compared with those treated with the subciliary approach (13.3 percent). There were four cases (12.5 percent) of postoperative facial infections. Two of these cases were resolved with systemic antibiotics, one was resolved with bone sequestrum resection, and one patient needed removal of the implant. Orbital infections were related in all cases to titanium osteosynthesis miniplates or skull bone graft. When comparing patients who were treated with and without antibiotics, no statistical differences (p = 0.958) were found relative to the presence of infections. Correction of hypoglobus is technically easier than enophthalmos, because enophthalmic correction requires a wide, deep subperiosteal dissection and implant positioning, posterior to the equator of the globe, with the inherent risk of orbital apex injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Craniofacial reconstruction with high-density porous polyethylene implants.
Menderes, A., Baytekin, C., Topcu, A., Yilmaz, M., & Barutcu, A. (2004) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200409000-00004 · Cited by 90
The Use of High-Density Porous Polyethylene as a Custom-Made Nasal Spreader Graft
Gürlek, A., Celik, M., Fariz, A., Ersöz-Öztürk, A., Eren, A. T., & Tenekeci, G. (2006) · Aesthetic Plastic Surgery · doi:10.1007/s00266-005-0119-8 · Cited by 47
Metadata
- Authors
- Villarreal, P. M., Monje, F., Morillo, A. J., Junquera, L. M., González, C., & Barbón, J. J.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2002-03
- Volume
- 109
- Issue
- 3
- Pages
- 877-885
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1977064560
- Cited by
- 111
- References
- 0
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Porous Polyethylene Implants in Orbital Floor Reconstruction. https://app.cochat.ai/papers/10.1097/00006534-200203000-00007
- The paper
- Villarreal, P. M., Monje, F., Morillo, A. J., Junquera, L. M., González, C., & Barbón, J. J. (2002). Porous Polyethylene Implants in Orbital Floor Reconstruction. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-200203000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.