Infrared ear thermometry
The DOI matches its Crossref record.
Abstract
Many hospitals are considering using infrared (IR) ear thermometers (also called tympanic membrane thermometers) as an alternative to traditional temperature-measurement devices. IR technology allows users to quickly and noninvasively measure body temperature by inserting a directional probe into the ear canal. For infection control, ear thermometers offer the advantages of not contacting mucous membranes and eliminating the need for special handling procedures. For use on unconscious patients or those who are otherwise unwilling or unable to cooperate with traditional techniques, IR ear thermometers offer a more comfortable and less stressful method of temperature taking for both patients and nurses, especially where rectal temperatures are used. The recent entry into this market by major companies and distributors and the release of several new IR ear thermometers have helped to further stimulate interest in this technology. However, a complete transition to IR ear thermometers throughout the hospital may not be necessary and should be made only after these devices have been successfully used in selected clinical locations, such as emergency departments, critical care areas, recovery areas, and labor and delivery rooms. Clinical users must be familiar with the technique needed for temperature measurement with these instruments and understand the differences between temperatures taken in the ear canal and those obtained from traditional sites. In the following article, we first present an overview of clinical thermometry, describing traditional temperature-measurement sites and devices. We then discuss the advantages and disadvantages of using the ear canal, including the tympanic membrane (TM), as a site for temperature measurement. In addition, we guide readers in determining the usefulness of IR ear thermometers.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rectal thermometry is regarded as an acceptable method for estimating core body temperature, 10 although stress or physical exertion may potentially increase this parameter.11”
From Evaluation of the Effects of Hospital Visit Stress on Physiologic Parameters in the Cat (2011) · cites this paper as [11]
Citations
Cites
Still being checked.
Cited by
Evaluation of the Effects of Hospital Visit Stress on Physiologic Parameters in the Cat
Quimby, J. M., Smith, M. L., & Lunn, K. F. (2011) · Journal of Feline Medicine and Surgery · doi:10.1016/j.jfms.2011.07.003 · Cited by 203
Greer, R. J., Cohn, L. A., Dodam, J. R., Wagner-Mann, C. C., & Mann, F. A. (2007) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.230.12.1841 · Cited by 101
Reliability of Infrared Tympanic Thermometry in the Detection of Rectal Fever in Children
Brennan, D. F., FALK, J., Rothrock, S. G., & KERR, R. (1995) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(95)70350-0 · Cited by 78
Kunkle, G. A., Nicklin, C. F., & Sullivan-Tamboe, D. L. (2004) · Journal of the American Animal Hospital Association · doi:10.5326/0400042 · Cited by 66
The efficacy of tepid sponge bathing to reduce fever in young children
Sharber, J. (1997) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(97)90099-1 · Cited by 63
Comparison of digital rectal and microchip transponder thermometry in cats.
Quimby, J. M., Olea‐Popelka, F. J., & Lappin, M. R. (2009) · PubMed Central · Cited by 62
Comparison of Rectal and Infrared Ear Temperatures in Older Hospital Inpatients
Smitz, S., Giagoultsis, T., Dewé, W., & Albert, A. (2000) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2000.tb03030.x · Cited by 56
An appraisal of temperature assessment by infrared emission detection tympanic thermometry
Terndrup, T. E. (1992) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)80067-8 · Cited by 46
Infrared Ear Thermometry in Water-Related Accidents—Not a Good Choice
Muth, C.-M., Shank, E. S., Hauser, B., Radermacher, P., Gröger, M., & Ehrmann, U. (2008) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2007.10.061 · Cited by 33
The Human Ear: Its Role in Forensic Practice
Swift, B., & Rutty, G. N. (2003) · Journal of Forensic Sciences · doi:10.1520/jfs2002251 · Cited by 30
Roberts, W. W., Dinkel, T. A., Schulam, P. G., Bonnell, L. J., & Kavoussi, L. R. (1997) · Surgical Endoscopy · doi:10.1007/s004649900575 · Cited by 25
Cadeddu, J. A., Jackman, S. V., & Schulam, P. G. (2001) · Journal of Endourology · doi:10.1089/08927790150501033 · Cited by 22
EFFECT OF CERUMEN ON INFRARED EAR TEMPERATURE MEASUREMENT
Hasel, K. L., & Erickson, R. S. (1995) · Journal of Gerontological Nursing · doi:10.3928/0098-9134-19951201-04 · Cited by 22
The use of infrared ear thermometers in pediatric and family practice offices.
SILVERMAN, B. G., Daley, W. R., & Rubin, J. D. (1998) · Europe PMC (PubMed Central) · Cited by 21
Fallis, W. M., & Christiani, P. (1999) · Journal of Obstetric, Gynecologic & Neonatal Nursing · doi:10.1111/j.1552-6909.1999.tb02007.x · Cited by 21
Piccione, G. G., Giannetto, C., Marafioti, S., Casella, S., Assenza, A., & Fazio, F. (2011) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2011.03.006 · Cited by 19
Evaluation of three brands of tympanic thermometer.
Hoffman, C., Boyd, M., Briere, B., Loos, F., & Norton, P. J. (1999) · Bond University Research Portal (Bond University) · Cited by 18
A comparison of temperature measurements using three ear thermometers
Weiss, M., Sitzer, V., Clarke, M., Haley, K. J., Richards, M., Sanchez, A., & Gocka, I. (1998) · Applied Nursing Research · doi:10.1016/s0897-1897(98)80274-7 · Cited by 9
Metot Karşilaştirma Çalişmalarinda Bland-Altman ve Tip II Regresyon Analizinin Karşilaştirilmasi
Saraçlı, S., & Çelik, H. (2012) · Sağlık Bilimlerinde Değer · Cited by 9
Infrared Tympanic Thermometry in the Evaluation of Pediatric Acute Otitis Media
Brennan, D. F., Falk, J. L., Rothrock, S. G., & Kerr, R. B. (1994) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1994.tb02643.x · Cited by 8
Muhammed, M. U., Musa, M. A., & Abdullahi, G. A. (2019) · International Journal of Research -GRANTHAALAYAH · doi:10.29121/granthaalayah.v7.i8.2019.639 · Cited by 7
Fallis, W. M., Brunsdon-Clark, B., Andries, A., & Gilbert, E. (2005) · Journal of Emergency Nursing · doi:10.1016/j.jen.2005.05.003 · Cited by 6
Statistical Issues in the Assessment of Health Outcomes in Children: A Methodological Review
Lancaster, G. (2009) · Journal of the Royal Statistical Society Series A (Statistics in Society) · doi:10.1111/j.1467-985x.2009.00590.x · Cited by 5
Basic principles of optical radiation and some common applications in anesthesia
Gravenstein, D., Lampotang, S., Huda, W., & Sultan, A. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02199705 · Cited by 4
The effect of ambulance treatment on patient temperature normalisation
Grantham, H. J. M., & FAWCETT, G. (1993) · Emergency Medicine Australasia · doi:10.1111/j.1442-2026.1993.tb00410.x · Cited by 1
A comparison of methods to reduce fever in young children
Sharber, J. (1994) · UA Campus Repository (The University of Arizona) · Cited by 1
(2005) · Journal of Emergency Nursing · doi:10.1016/j.jen.2005.09.003
Tocco, F., Ghiani, G. M., Palmas, M., Ruggiu, M., Velluzzi, F., Deledda, A., Masala, A., Fois, A., Manuello, A., Dell’Osa, A., et al. (2025) · PORTO@Iris · doi:10.69076/jomac.2025.0028
Metadata
- Authors
- NOBEL, J. J.
- Corresponding author
- NOBEL, JOEL J.
- Venue
- Pediatric Emergency Care
- Published
- 1992-02
- Volume
- 8
- Issue
- 1
- Pages
- 54-58
- ISSN
- 0749-5161 (ISSN-L)
- OpenAlex
- W2031622910
- Cited by
- 27
- References
- 0
- Citations by year
- 2019: 1 · 2012: 1
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Pediatric Emergency Care (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- body temperature measurement, tympanic membrane, infection control, non-invasive temperature measurement, emergency department, intensive care, labor and delivery
- MeSH terms
- Humans, Infrared Rays, Thermometers, Tympanic Membrane
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.