THE CHICK CHORIOALLANTOIC MEMBRANE AS A MODEL TISSUE FOR SURGICAL RETINAL RESEARCH AND SIMULATION
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In Brief Purpose: We describe the use of chick chorioallantoic membrane (CAM) as a model system for the study of the precision and safety of vitreoretinal microsurgical instruments and techniques. Methods: The CAM was prepared for experimentation with and without its inner shell membrane (ISM) attached for in vivo and in vitro experiments that simulated medical and surgical interventions on the retina. Results: The CAM’s ease of use, low cost, and anatomic structure make it a convenient model for surgical retinal and retinal vascular modeling. Conclusion: While CAM has been used extensively in the past for ocular angiogenesis studies, we describe the tissue as a useful tool for a variety of other applications, including (1) testing of novel surgical tools and techniques for cutting and coagulating retina and its vasculature, (2) testing vessel cannulation and injection techniques, (3) angiographic studies, and (4) endoscopic surgery. We describe the use of chick chorioallantoic membrane (CAM) as a model system for the study of vitreoretinal microsurgical instruments and techniques. The uses include: testing novel surgical tools and techniques for cutting and coagulating retina and its vasculature, testing vessel cannulation and injection techniques, angiographic studies, and endoscopic surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complex formation between ethidium bromide and nucleic acids
Waring, M. J. (1965) · Journal of Molecular Biology · doi:10.1016/s0022-2836(65)80096-1 · Cited by 1,512
Cited by
OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
The chicken chorioallantoic membrane model in biology, medicine and bioengineering
Nowak-Sliwinska, P., Segura, T., & Iruela-Arispe, M. L. (2014) · Angiogenesis · doi:10.1007/s10456-014-9440-7 · Cited by 478
Development and application of a new steady-hand manipulator for retinal surgery
Mitchell, B., Koo, J., Iordachita, I., Kazanzides, P., Kapoor, A., Handa, J., Hager, G., & Taylor, R. (2007) · Proceedings 2007 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2007.363056 · Cited by 174
KUE, C. S., TAN, K. Y., LAM, M. L., & LEE, H. B. (2015) · Experimental Animals · doi:10.1538/expanim.14-0059 · Cited by 168
Tissue Damage by Pulsed Electrical Stimulation
Butterwick, A., Vankov, A., Huie, P., Freyvert, Y., & Palanker, D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.908310 · Cited by 136
“Additionally, this source does not require an extensive animal protocol during this period of development [26].”
BackgroundMethodSelf-citation
Metadata
- Authors
- LENG, T., MILLER, J. M., BILBAO, K. V., PALANKER, D. V., HUIE, P., & BLUMENKRANZ, M. S.
- Venue
- Retina
- Published
- 2004-06
- Volume
- 24
- Issue
- 3
- Pages
- 427-434
- ISSN
- 0275-004X (ISSN-L)
- OpenAlex
- W2007333437
- Cited by
- 103
- References
- 1
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE CHICK CHORIOALLANTOIC MEMBRANE AS A MODEL TISSUE FOR SURGICAL RETINAL RESEARCH AND SIMULATION. https://app.cochat.ai/papers/10.1097/00006982-200406000-00014
- The paper
- LENG, T., MILLER, J. M., BILBAO, K. V., PALANKER, D. V., HUIE, P., & BLUMENKRANZ, M. S. (2004). THE CHICK CHORIOALLANTOIC MEMBRANE AS A MODEL TISSUE FOR SURGICAL RETINAL RESEARCH AND SIMULATION. Retina. https://doi.org/10.1097/00006982-200406000-00014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.