Cited by 174Teleoperation and Haptic SystemsRetinal and Macular SurgerySoft Robotics and Applications

Development and application of a new steady-hand manipulator for retinal surgery

Mitchell, Ben, Koo, John, Iordachita, Iulian, Kazanzides, Peter, Kapoor, Ankur, Handa, James, Hager, Gregory, Taylor, Russell·2007·Proceedings 2007 IEEE International Conference on Robotics and Automation

Abstract

This paper describes the development and initial testing of a new and optimized version of a steady-hand manipulator for retinal microsurgery. In the steady-hand paradigm, the surgeon and the robot share control of a tool attached to the robot through a force sensor. The robot controller senses forces exerted by the operator on the tool and uses this information in various control modes to provide smooth, tremor-free, precise positional control and force scaling. The steady-hand manipulator reported here has been specifically designed with the unique constraints of retinal microsurgery in mind. In particular, the system makes use of a compact wrist design that places the bulk of the robot away from the operating field. The resulting system has high efficacy, flexibility and ergonomics while meeting the accuracy and safety requirements of microsurgery. We have now tested this robot on a biological model system and we report a protocol for reliably cannulating ~80 mum OD veins (the size of veins in the human retina) using the system

Integrity signals

Registry

Crossref · 10.1109/robot.2007.363056

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Mitchell, B., Koo, J., Iordachita, I., Kazanzides, P., Kapoor, A., Handa, J., Hager, G., & Taylor, R.
Venue
Proceedings 2007 IEEE International Conference on Robotics and Automation
Publisher
IEEE
Published
2007-04
Pages
623-629
ISSN
1050-4729 (ISSN-L)
OpenAlex
W2153752636
Cited by
174
References
19
Citations by year
2026: 1 · 2025: 4 · 2024: 10 · 2023: 8 · 2022: 13 · 2021: 8 · 2020: 7 · 2019: 7 · 2018: 11 · 2017: 12 · 2016: 4 · 2015: 10 · 2014: 8 · 2013: 12 · 2012: 11
FWCI
42.25
Type
conference paper
Language
en
Open access
closed
Locations
Proceedings - IEEE International Conference on Robotics and Automation/Proceedings (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal and Macular Surgery
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
Keywords
retinal microsurgery, surgical robotics, force sensor, shared control, tremor suppression, force scaling, human factors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review