Development and application of a new steady-hand manipulator for retinal surgery
Abstract
This paper describes the development and initial testing of a new and optimized version of a steady-hand manipulator for retinal microsurgery. In the steady-hand paradigm, the surgeon and the robot share control of a tool attached to the robot through a force sensor. The robot controller senses forces exerted by the operator on the tool and uses this information in various control modes to provide smooth, tremor-free, precise positional control and force scaling. The steady-hand manipulator reported here has been specifically designed with the unique constraints of retinal microsurgery in mind. In particular, the system makes use of a compact wrist design that places the bulk of the robot away from the operating field. The resulting system has high efficacy, flexibility and ergonomics while meeting the accuracy and safety requirements of microsurgery. We have now tested this robot on a biological model system and we report a protocol for reliably cannulating ~80 mum OD veins (the size of veins in the human retina) using the system
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Existing robotic systems often have their center of motion at a separate location from the site of insertion into the eye.
“existing systems often have their RCM at a separate location (68).”
From Subretinal therapy: technological solutions to surgical and immunological challenges (2022) · cites this paper as [68]
Cites
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. S. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 999 · see citing works
Self-citationA Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528 · see citing works
Self-citationEngineering data compendium : human perception and performance
Boff, K. R., & Lincoln, J. E. (1988) · Medical Entomology and Zoology · Cited by 428 · see citing works
Vision-Assisted Control for Manipulation Using Virtual Fixtures
Bettini, A., Marayong, P., Lang, S., Okamura, A. M., & Hager, G. D. (2004) · IEEE Transactions on Robotics · doi:10.1109/tro.2004.829483 · Cited by 265 · see citing works
Self-citationA teleoperated microsurgical robot and associated virtual environment for eye surgery
Hunter, I. W., Doukoglou, T. D., Lafontaine, S. R., Charette, P. G., Jones, L. A., Sagar, M. A., Mallinson, G. D., & Hunter, P. J. (1993) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1993.2.4.265 · Cited by 164 · see citing works
Advanced Micropipette Techniques for Cell Physiology
Brown, K. T., & Flaming, D. G. (1987) · Works - Scholarship, Research, & Creative Expression (Swarthmore College) · Cited by 132 · see citing works
Physiological tremor amplitude during retinal microsurgery
Singh, S. P. N., & Riviere, C. N. (2002) · Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference (IEEE Cat. No.02CH37342) · doi:10.1109/nebc.2002.999520 · Cited by 131 · see citing works
Human-Machine Collaborative Systems for Microsurgical Applications
Kragić, D., Marayong, P., Li, M., Okamura, A. M., & Hager, G. D. (2005) · The International Journal of Robotics Research · doi:10.1177/0278364905057059 · Cited by 126 · see citing works
Self-citationTHE CHICK CHORIOALLANTOIC MEMBRANE AS A MODEL TISSUE FOR SURGICAL RETINAL RESEARCH AND SIMULATION
Leng, T., Miller, J. M. L., Bilbao, K., et al. (2004) · Retina · doi:10.1097/00006982-200406000-00014 · Cited by 103 · see citing works
Tetrobot: A Modular Approach to Reconfigurable Parallel Robotics
Hamlin, G. J., & Sanderson, A. C. (1997) · doi:10.1007/978-1-4615-5471-4 · Cited by 93 · see citing works
Development of remote microsurgery robot and new surgical procedure for deep and narrow space
Ikuta, K., Yamamoto, K., & Sasaki, K. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2003.1241740 · Cited by 87 · see citing works
ERGONOMICS APPLIED TO THE PRACTICE OF MICROSURGERY<sup>1</sup>
Patkin, M. (1977) · Australian and New Zealand Journal of Surgery · doi:10.1111/j.1445-2197.1977.tb04297.x · Cited by 80 · see citing works
Constrained control for surgical assistant robots
Kapoor, A., Li, M., & Taylor, R. H. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1641189 · Cited by 75 · see citing works
Self-citationVirtual fixture architectures for telemanipulation
Abbott, J. J., & Okamura, A. M. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2003.1242016 · Cited by 61 · see citing works
Wollensak, G., Spoerl, E., Wirbelauer, C., et al. (2004) · Ophthalmologica · doi:10.1159/000078621 · Cited by 56 · see citing works
(1989) · Choice Reviews Online · doi:10.5860/choice.27-0955 · Cited by 55 · see citing works
Design of a surgeon-machine interface for teleoperated microsurgery
Charles, S., Williams, R. E., & Hamel, B. (2003) · doi:10.1109/iembs.1989.96030 · Cited by 29 · see citing works
An Augmentation System for Fine Manipulation
Kumar, R., Hager, G. D., Barnes, A., et al. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_99 · Cited by 22 · see citing works
Self-citationRotational technique and microsurgery
Weinrib, H. P., & Cook, J. Q. (1984) · Microsurgery · doi:10.1002/micr.1920050408 · Cited by 5 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
New steady-hand Eye Robot with micro-force sensing for vitreoretinal surgery
Uneri, A., Balicki, M. A., Handa, J., Gehlbach, P., Taylor, R. H., & Iordachita, I. (2010) · 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2010.5625991 · Cited by 291 · see citing works
Self-citationMicron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270 · see citing works
Iordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181 · see citing works
Self-citationPreliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery
Gonenc, B., Balicki, M. A., Handa, J., Gehlbach, P., Riviere, C. N., Taylor, R. H., & Iordachita, I. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6385715 · Cited by 54 · see citing works
“Apart from these, JHU Steady-hand Eye Robot was developed based on a cooperative control scheme between the surgeon and a stiff non-backdrivable robot arm to combine manipulative transparency and immediacy of hand held tools with precision and sensitivity of a machine [15,20,21].”
MethodSelf-citationSubretinal therapy: technological solutions to surgical and immunological challenges
Ladha, R., Caspers, L. E., Willermain, F., & de Smet, M. D. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.846782 · Cited by 54 · see citing works
- Authors
- Mitchell, B., Koo, J., Iordachita, I., Kazanzides, P., Kapoor, A., Handa, J., Hager, G., & Taylor, R.
- Venue
- Proceedings 2007 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2007-04
- Pages
- 623-629
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2153752636
- Cited by
- 174
- References
- 19
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 10 · 2023: 8 · 2022: 13 · 2021: 8 · 2020: 7 · 2019: 7 · 2018: 11 · 2017: 12 · 2016: 4 · 2015: 10 · 2014: 8 · 2013: 12 · 2012: 11
- FWCI
- 42.25
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Proceedings - IEEE International Conference on Robotics and Automation/Proceedings (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal and Macular Surgery
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- retinal microsurgery, surgical robotics, force sensor, shared control, tremor suppression, force scaling, human factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review