CoChat

ELECTROPHYSIOLOGIC AND RETINAL PENETRATION STUDIES FOLLOWING INTRAVITREAL INJECTION OF BEVACIZUMAB (AVASTIN)

SHAHAR, JONATHAN, AVERY, ROBERT L., HEILWEIL, GAD, BARAK, ADIEL, ZEMEL, ESTHER, LEWIS, GEOFFREY P., JOHNSON, PATRICK T., FISHER, STEVEN K., PERLMAN, IDO, LOEWENSTEIN, ANAT · 2006 · Retina
Cited by 350

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

In Brief Purpose: Intravitreal bevacizumab (Avastin; Genentech Inc., San Francisco, CA) is a new treatment for age-related macular degeneration. The aim of this study was to evaluate retinal penetration and toxicity of bevacizumab. Methods: Ten albino rabbits were injected intravitreally with 0.1 mL (2.5 mg) of Avastin into one eye and 0.1 mL saline into the fellow eye. The electroretinogram (ERG) was recorded after 3 hours, 3 days, and 1, 2, and 4 weeks. The visual evoked potential (VEP) was recorded after 4 weeks. Confocal immunohistochemistry was used to assess retinal penetration. Results: The ERG responses of the control and experimental eyes were similar in amplitude and pattern throughout the follow-up period. The flash VEP responses of the experimental eyes were of normal pattern and amplitude and did not differ from those recorded by stimulation of the control eye alone. Full thickness retinal penetration was present at 24 hours and was essentially absent at 4 weeks. Conclusions: Bevacizumab was found to be nontoxic to the retina of rabbits based on electrophysiologic studies. Full thickness retinal penetration may explain observed clinical effects of intravitreal bevacizumab. Although it is difficult to directly extrapolate to humans, our study supports the safe use of intravitreal bevacizumab injection. Ten rabbits were injected intravitreally with 2.5 mg of bevacizumab. Electroretinogram and visual evoked potential were recorded after various time intervals. Bevacizumab was found to be nontoxic to the rabbit retina, and to penetrate full thickness retina at 24 hours after injection. This study supports the safe use of intravitreal bevacizumab injection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006982-200603000-00002

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 350

Metadata

Authors
SHAHAR, J., AVERY, R. L., HEILWEIL, G., BARAK, A., ZEMEL, E., LEWIS, G. P., JOHNSON, P. T., FISHER, S. K., PERLMAN, I., & LOEWENSTEIN, A.
Venue
Retina
Published
2006-03
Volume
26
Issue
3
Pages
262-269
ISSN
0275-004X (ISSN-L)
OpenAlex
W1988233478
Cited by
350
References
16
FWCI
50.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.