Detection of Treponema pallidum by a Fluorescent Monoclonal Antibody Test
The DOI matches its Crossref record.
Abstract
Definitive diagnosis of early syphilis currently requires dark-field microscopy and/or a newly reactive serologic test for syphilis. The efficacy of dark-field microscopy depends on the availability of a microscope, the skill of the clinician in obtaining a specimen, and the expertise of the microscopist. Serologic diagnosis may be affected by the delay between the appearance of the primary chancre and the onset of serologic reactivity. We used a pathogen-specific fluorescein-conjugated monoclonal antibody to examine lesion exudates from 128 consecutive patients and compared these data with results of dark-field microscopy, the rapid plasma reagin (RPR) test, and the fluorescent treponemal antibody-absorbed (FTA-Abs) test. The monoclonal antibody test demonstrated Treponema pallidum in 48 (73%) of 66 patients with infectious syphilis, while dark-field microscopy was positive for 52 (79%) of 66 patients. None of 62 patients without syphilis was positive by either test. The FTA-Abs test was reactive for 61 patients (92%) of the 66 with infectious syphilis. Thus the fluorescent monoclonal antibody test for detection of T. pallidum in direct smears is as sensitive and specific as dark-field microscopy for the diagnosis of infectious syphilis. It has the potential to provide a convenient, accurate means for definitive diagnosis of genital ulcer disease by health care personnel without ready access to dark-field microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laboratory diagnosis and interpretation of tests for syphilis
Larsen, S. A., Steiner, B. M., & Rudolph, A. H. (1995) · Clinical Microbiology Reviews · doi:10.1128/cmr.8.1.1 · Cited by 781
Syphilis: Review with Emphasis on Clinical, Epidemiologic, and Some Biologic Features
Singh, A. E., & Romanowski, B. (1999) · Clinical Microbiology Reviews · doi:10.1128/cmr.12.2.187 · Cited by 638
Self-citationOrle, K. A., Gates, C. A., Martin, D. H., Body, B. A., & Weiss, J. B. (1996) · Journal of Clinical Microbiology · doi:10.1128/jcm.34.1.49-54.1996 · Cited by 319
Giacani, L., & Lukehart, S. A. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00070-13 · Cited by 220
Self-citationCDC Laboratory Recommendations for Syphilis Testing, United States, 2024
Papp, J. R., Park, I. U., Fakile, Y., Pereira, L., Pillay, A., & Bolan, G. A. (2024) · MMWR. Recommendations and Reports · doi:10.15585/mmwr.rr7301a1 · Cited by 197
“For manual treponemal tests, one study found the specificity of FTA-ABS to be 87% (n = 128 patients) ( 141 ), whereas the specificity ranges of FTA-ABS and TPPA (95%–100% and 94%–100%, respectively) were similar in older studies ( 102 , 113 – 115 , 117 , 118 , 122 – 127 ).”
BackgroundResult
Metadata
- Authors
- ROMANOWSKI, B., FORSEY, E., PRASAD, E., LUKEHART, S., TAM, M., & HOOK, E. W.
- Venue
- Sexually Transmitted Diseases
- Published
- 1987-07
- Volume
- 14
- Issue
- 3
- Pages
- 156-159
- ISSN
- 0148-5717 (ISSN-L)
- OpenAlex
- W2060026964
- Cited by
- 64
- References
- 0
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Treponema pallidum by a Fluorescent Monoclonal Antibody Test. https://app.cochat.ai/papers/10.1097/00007435-198707000-00007
- The paper
- ROMANOWSKI, B., FORSEY, E., PRASAD, E., LUKEHART, S., TAM, M., & HOOK, E. W. (1987). Detection of Treponema pallidum by a Fluorescent Monoclonal Antibody Test. Sexually Transmitted Diseases. https://doi.org/10.1097/00007435-198707000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.