Biomechanical Analysis of Lumbosacral Fixation

McCord, David H., Cunningham, Bryan W., Shono, Yasahiro, Myers, Jordan J., McAfee, Paul C.·1992·Spine

Abstract

Flexion testing was performed until failure on 66 lumbosacral bovine spinal segments comparing ten different lumbosacral instrumentation techniques. Maximum flexion moment at failure, flexural stiffness, and maximum angulation of the lumbosacral joint at failure were determined as well as strain measurements across the anterior aspect of the lumbosacral intervertebral disc using an extensometer. The maximum moment at failure was significantly greater for the only two devices that extended fixation into the ilium anterior to the projected image of the middle osteoligamentous column: ISOLA Galveston and ISOLA iliac screws (F = 12.2, P less than 0.001). The maximum stiffness at failure reinforced these findings (F = 23.7, P less than 0.001). A second subset of stability showed the advantages of S2 pedicle fixation by increasing the flexural lever arm (Cotrel-Dubousset butterfly plate, and Cotrel-Dubousset Chopin block, P less than 0.05). This exhaustive in vitro biomechanical study introduces the concept of a pivot point at the lumbosacral joint at the intersection of the middle osteoligamentous column (sagittal plane) and the lumbosacral intervertebral disc (transverse plane). A spinal surgeon can increase the stability of lumbosacral instrumentation by extending fixation through the anterior sacral cortex (Steffee plate group with pedicle screws that medially converge in a triangular fashion). A means of enhancing this fixation was to achieve more inferior purchase by extending the fixation down to the S2 pedicle (Cotrel-Dubousset Chopin and Cotrel-Dubousset butterfly groups). However, the best fixation was achieved by obtaining purchase between the iliac cortices down into the superior acetabular bone.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-199208001-00004

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 331

Metadata

Authors
McCord, D. H., Cunningham, B. W., Shono, Y., Myers, J. J., & McAfee, P. C.
Venue
Spine
Published
1992-08
Volume
17
Issue
8 Suppl
Pages
235-243
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2002185245
Cited by
331
References
4
FWCI
1.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biomechanical Analysis of Lumbosacral Fixation. https://app.cochat.ai/papers/10.1097/00007632-199208001-00004
The paper
McCord, D. H., Cunningham, B. W., Shono, Y., Myers, J. J., & McAfee, P. C. (1992). Biomechanical Analysis of Lumbosacral Fixation. Spine. https://doi.org/10.1097/00007632-199208001-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.