The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Biomechanical Analysis of Lumbosacral Fixation
Abstract
Flexion testing was performed until failure on 66 lumbosacral bovine spinal segments comparing ten different lumbosacral instrumentation techniques. Maximum flexion moment at failure, flexural stiffness, and maximum angulation of the lumbosacral joint at failure were determined as well as strain measurements across the anterior aspect of the lumbosacral intervertebral disc using an extensometer. The maximum moment at failure was significantly greater for the only two devices that extended fixation into the ilium anterior to the projected image of the middle osteoligamentous column: ISOLA Galveston and ISOLA iliac screws (F = 12.2, P less than 0.001). The maximum stiffness at failure reinforced these findings (F = 23.7, P less than 0.001). A second subset of stability showed the advantages of S2 pedicle fixation by increasing the flexural lever arm (Cotrel-Dubousset butterfly plate, and Cotrel-Dubousset Chopin block, P less than 0.05). This exhaustive in vitro biomechanical study introduces the concept of a pivot point at the lumbosacral joint at the intersection of the middle osteoligamentous column (sagittal plane) and the lumbosacral intervertebral disc (transverse plane). A spinal surgeon can increase the stability of lumbosacral instrumentation by extending fixation through the anterior sacral cortex (Steffee plate group with pedicle screws that medially converge in a triangular fashion). A means of enhancing this fixation was to achieve more inferior purchase by extending the fixation down to the S2 pedicle (Cotrel-Dubousset Chopin and Cotrel-Dubousset butterfly groups). However, the best fixation was achieved by obtaining purchase between the iliac cortices down into the superior acetabular bone.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Biomechanics of the Spine
White, A. A., & Panjabi, M. M. (1978) · Medical Entomology and Zoology · Cited by 2,265
Introduction to sample size determination and power analysis for clinical trials
Lachin, J. M. (1981) · Controlled Clinical Trials · doi:10.1016/0197-2456(81)90001-5 · Cited by 1,012
1989 Volvo Award in Basic Science: Device-Related Osteoporosis with Spinal Instrumentation
McAFEE, P. C., FAREY, I. D., SUTTERLIN, C. E., GURR, K. R., WARDEN, K. E., BIOMED, M., & CUNNINGHAM, B. W. (1989) · Spine · doi:10.1097/00007632-198909000-00003 · Cited by 246
Self-citationAn anatomical comparison of the human and bovine thoracolumbar spine
Cotterill, P. C., Kostuik, J. P., D'Angelo, G., Fernie, G. R., & Maki, B. E. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040306 · Cited by 162
Cited by
En bloc resection of primary sacral tumors: classification of surgical approaches and outcome
Fourney, D. R., Rhines, L. D., Hentschel, S. J., Skibber, J. M., Wolinsky, J.-P., Weber, K. L., Suki, D., Gallia, G. L., Garonzik, I., & Gokaslan, Z. L. (2005) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2005.3.2.0111 · Cited by 291
Potter, B. K., Freedman, B. A., Verwiebe, E. G., Hall, J. M., Polly, D. W., & Kuklo, T. R. (2005) · Journal of Spinal Disorders & Techniques · doi:10.1097/01.bsd.0000166642.69189.45 · Cited by 280
Metadata
- Authors
- McCord, D. H., Cunningham, B. W., Shono, Y., Myers, J. J., & McAfee, P. C.
- Venue
- Spine
- Published
- 1992-08
- Volume
- 17
- Issue
- 8 Suppl
- Pages
- 235-243
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2002185245
- Cited by
- 331
- References
- 4
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomechanical Analysis of Lumbosacral Fixation. https://app.cochat.ai/papers/10.1097/00007632-199208001-00004
- The paper
- McCord, D. H., Cunningham, B. W., Shono, Y., Myers, J. J., & McAfee, P. C. (1992). Biomechanical Analysis of Lumbosacral Fixation. Spine. https://doi.org/10.1097/00007632-199208001-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.