Finite-Element Stress Analysis of the Normal and Osteoporotic Lumbar Vertebral Body
The DOI matches its Crossref record.
Abstract
A finite-element model of an isolated elderly human L3 vertebral body was developed to study how material properties and loading conditions influence end-plate and cortical-shell displacements and stresses. The model consisted of an idealized geometric representation of an isolated vertebral body, with a 1-mm-thick end plate and cortical shell. For uniform compression, large tensile stresses occurred all around the cortical shell just below the end plate as a result of bending of the cortical shell as it supported the end plate. Large tensile bending stresses also developed in the inferior surface of the end plate. Equal reductions in both trabecular and cortical bone moduli increased displacements but did not affect peak stresses. A 50% reduction in trabecular bone modulus alone increased peak stresses in the end plate by 74%. Elimination of the cortical shell reduced peak stresses in the end plate by approximately 20%. For nonuniform, anteriorly eccentric compression, peak stresses everywhere changed by less than 11% but moved to the anterior aspect. When material properties were adjusted to represent osteoporosis with disproportionate reductions in trabecular (50% decrease) and cortical (25% decrease) bone moduli, anterior compression increased peak stresses by up to 250% compared to uniform compression. If fractures are initiated in regions of large tensile stresses, the results from this relatively simple model may explain how central end-plate and transverse fractures initiate from uniform compression of the end plate. Furthermore, for anterior compression, disproportionate modulus reductions in trabecular and cortical bone may substantially increase end plate and cortical shell stresses, suggesting a cause of age-related spine fractures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone mechanical properties and changes with osteoporosis
Osterhoff, G., Morgan, E. F., Shefelbine, S. J., Karim, L., McNamara, L. M., & Augat, P. (2016) · Injury · doi:10.1016/s0020-1383(16)47003-8 · Cited by 557
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationLoad Sharing Between the Shell and Centrum in the Lumbar Vertebral Body
Silva, M. J., Keaveny, T. M., & Hayes, W. C. (1997) · Spine · doi:10.1097/00007632-199701150-00004 · Cited by 195
Self-citationMechanical and morphological variation of the human lumbar vertebral cortical and trabecular bone
Roy, M. E., Rho, J.-Y., Tsui, T. Y., Evans, N. D., & Pharr, G. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199902)44:2<191::aid-jbm9>3.0.co;2-g · Cited by 159
Development and Validation of a Predictive Bone Fracture Risk Model for Astronauts
Nelson, E. S., Lewandowski, B., Licata, A., & Myers, J. G. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9779-x · Cited by 50
Metadata
- Authors
- Mizrahi, J., Silva, M. J., Keaveny, T. M., Edwards, W. T., & Hayes, W. C.
- Venue
- Spine
- Published
- 1993-10
- Volume
- 18
- Issue
- Supplement
- Pages
- 2088-2096
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1991899431
- Cited by
- 93
- References
- 0
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.