The DOI matches its Crossref record.
Lumbar Interbody Cages
Abstract
Interbody cage devices, used to assist interbody fusion, are rapidly gaining popularity in the surgical management of chronic low back pain. This update provides a structural classification of commonly used devices and assesses them against a set of clearly defined surgical goals, including ability to correct the existing mechanical deformation, ability to provide mechanical stability, ability to provide a suitable environment for arthrodesis, and ability to limit "built-in" morbidity. In addition, the materials used in the devices are examined regarding their biomechanical, biologic, and radiographic characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Current Concepts Review - Interbody Fusion Cages in Reconstructive Operations on the Spine*
MCAFEE, P. C. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199906000-00014 · Cited by 306
Polikeit, A., Ferguson, S. J., Nolte, L. P., & Orr, T. E. (2003) · European Spine Journal · doi:10.1007/s00586-002-0505-8 · Cited by 287
In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages
van Dijk, M., Tunc, D. C., Smit, T. H., Higham, P., Burger, E. H., & Wuisman, P. I. J. M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10466 · Cited by 78
Metadata
- Authors
- Weiner, B. K., & Fraser, R. D.
- Venue
- Spine
- Published
- 1998-03
- Volume
- 23
- Issue
- 5
- Pages
- 634-640
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2413803534
- Cited by
- 242
- References
- 0
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lumbar Interbody Cages. https://app.cochat.ai/papers/10.1097/00007632-199803010-00020
- The paper
- Weiner, B. K., & Fraser, R. D. (1998). Lumbar Interbody Cages. Spine. https://doi.org/10.1097/00007632-199803010-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.