The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Current Concepts Review - Interbody Fusion Cages in Reconstructive Operations on the Spine*
Abstract
During the last five years, surgeons around the world have inserted more than 80,000 lumbar interbody fusion cages; in the United States alone, an estimated 5000 such devices are implanted each month. The recent interest in performing lumbar interbody arthrodesis with use of cages is attributable to three factors: the high rate of failure associated with use of bone graft alone3,22,26,45,46,71,82,84,94,96,106,107; the high rate of failure associated with use of posterior pedicle-screw instrumentation39,97,102; and the high rate of success associated with use of so-called stand-alone anterior fusion cages and autogenous bone graft, obviating the need to perform a 360-degree (combined anterior and posterior) lumbar arthrodesis with use of posterior instrumentation77. The purpose of the current review is to summarize the information in the literature with regard to the background, rationale, indications, techniques, results, and possible future developments of interbody arthrodesis for reconstruction of the spine. Early techniques of arthrodesis with use of allograft or autogenous graft and without instrumentation were associated with a high rate of failure. In a classic study, Stauffer and Coventry96 reported on eighty-three patients who had had an anterior interbody arthrodesis between 1959 and 1967. Of seventy-seven patients who were followed clinically for an average of 3.75 years after the procedure, twenty-eight (36 percent) had good (76 to 100 percent) relief of pain, fifteen (19 percent) had fair (26 to 75 percent) relief, and thirty-four (44 percent) had poor (0 to 25 percent) relief. Thirty (44 percent) of sixty-eight patients who were evaluated radiographically at a minimum of eighteen months postoperatively had a pseudarthrosis. Stauffer and Coventry defined radiographic fusion as “a pattern …
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Degenerative disk disease: assessment of changes in vertebral body marrow with MR imaging.
Modic, M. T., Steinberg, P. M., Ross, J. S., Masaryk, T. J., & Carter, J. R. (1988) · Radiology · doi:10.1148/radiology.166.1.3336678 · Cited by 2,061
BRUDER, S. P., KRAUS, K. H., GOLDBERG, V. M., & KADIYALA, S. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199807000-00007 · Cited by 877
A Prospective, Randomized Study of Lumbar Fusion: Priliminary Results
Zdeblick, T. A. (1993) · Spine · doi:10.1097/00007632-199306150-00006 · Cited by 766
Kuslich, S. D., Ulstrom, C. L., Griffith, S. L., Ahern, J. W., & Dowdle, J. D. (1998) · Spine · doi:10.1097/00007632-199806010-00019 · Cited by 508
Threaded Titanium Cages for Lumbar Interbody Fusions
Ray, C. D. (1997) · Spine · doi:10.1097/00007632-199703150-00019 · Cited by 452
Brantigan, J. W., & Steffee, A. D. (1993) · Lumbar Fusion and Stabilization · doi:10.1007/978-4-431-68234-9_41 · Cited by 424
Arthrodesis by the Distraction-Compression Method Using a Stainless Steel Implant
Bagby, G. W. (1988) · Orthopedics · doi:10.3928/0147-7447-19880601-13 · Cited by 369
PROLO, D. J., OKLUND, S. A., & BUTCHER, M. (1986) · Spine · doi:10.1097/00007632-198607000-00012 · Cited by 336
Cook, S. D., Dalton, J. E., Tan, E. H., Whitecloud, T. S., & Rueger, D. C. (1994) · Spine · doi:10.1097/00007632-199408000-00002 · Cited by 261
1989 Volvo Award in Basic Science: Device-Related Osteoporosis with Spinal Instrumentation
McAFEE, P. C., FAREY, I. D., SUTTERLIN, C. E., GURR, K. R., WARDEN, K. E., BIOMED, M., & CUNNINGHAM, B. W. (1989) · Spine · doi:10.1097/00007632-198909000-00003 · Cited by 246
Self-citation
Cited by
Gittens, R. A., Olivares-Navarrete, R., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.037 · Cited by 447
Polikeit, A., Ferguson, S. J., Nolte, L. P., & Orr, T. E. (2003) · European Spine Journal · doi:10.1007/s00586-002-0505-8 · Cited by 287
Potter, B. K., Freedman, B. A., Verwiebe, E. G., Hall, J. M., Polly, D. W., & Kuklo, T. R. (2005) · Journal of Spinal Disorders & Techniques · doi:10.1097/01.bsd.0000166642.69189.45 · Cited by 280
In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages
van Dijk, M., Tunc, D. C., Smit, T. H., Higham, P., Burger, E. H., & Wuisman, P. I. J. M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10466 · Cited by 78
Metadata
- Authors
- MCAFEE, P. C.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1999-06
- Volume
- 81
- Issue
- 6
- Pages
- 859-80
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W15059537
- Cited by
- 306
- References
- 21
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current Concepts Review - Interbody Fusion Cages in Reconstructive Operations on the Spine*. https://app.cochat.ai/papers/10.2106/00004623-199906000-00014
- The paper
- MCAFEE, P. C. (1999). Current Concepts Review - Interbody Fusion Cages in Reconstructive Operations on the Spine*. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199906000-00014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.