The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Study of the Diagnostic Accuracy and Reliability of the Scoliometer and Adamʼs Forward Bend Test
Abstract
STUDY DESIGN: Study of the diagnostic accuracy and interexaminer reliability of scoliosis diagnostic tests. OBJECTIVES: To estimate the sensitivity, specificity, and predictive value of the Scoliometer (National Scoliosis Foundation, Watertown, MA) and Adam's forward bend test in diagnosing scoliosis, and to determine the interexaminer reliability of the Scoliometer and Adam's forward bend test. SUMMARY OF BACKGROUND DATA: Exposure to diagnostic radiation in patients with adolescent idiopathic scoliosis may result in a small but significant increase in cancer rates. The full-spine radiographic examination remains the standard procedure for the assessment of scoliosis. There is a need for a valid and reliable noinvasive test to assess scoliosis. METHODS: Two examiners independently assessed 105 patients presenting to a scoliosis clinic for trunk asymmetry with Adam's forward bend test and axial trunk rotation with the Scoliometer. The Cobb method served as the gold standard. RESULTS: The interexaminer agreement for the Scoliometer is excellent in the thoracic spine and substantial in the lumbar spine. The interexaminer measurement error shows poor precision for thoracic and lumbar Scoliometer measurements. The interexaminer agreement for Adam's forward bend test is substantial in the thoracic spine and poor in the lumbar spine. Adam's forward bend test is more sensitive than the Scoliometer in detecting thoracic curves measuring 20 degrees or more by the Cobb method. Receiver operating characteristic curve analysis suggests that the use of the Scoliometer marginally improves the ability of diagnosing a scoliosis in the thoracic spine. CONCLUSIONS: The Scoliometer and Adam's forward bend tests have adequate interexaminer reliability for the assessment of thoracic curves. The Scoliometer has better interexaminer agreement in the lumbar spine. However, the Scoliometer has a high level of interexaminer measurement error that limits its use as an outcome instrument. Because Adam's forward bend test is more sensitive than the Scoliometer, the authors believe that it remains the best noninvasive clinical test to evaluate scoliosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Cited by
Negrini, S., Donzelli, S., Aulisa, A. G., Czaprowski, D., Schreiber, S., de Mauroy, J. C., Diers, H., Grivas, T. B., Knott, P., Kotwicki, T., et al. (2018) · Scoliosis and Spinal Disorders · doi:10.1186/s13013-017-0145-8 · Cited by 1,174
Negrini, S., Aulisa, A. G., Aulisa, L., Circo, A. B., de Mauroy, J. C., Durmala, J., Grivas, T. B., Knott, P., Kotwicki, T., Maruyama, T., et al. (2012) · Scoliosis · doi:10.1186/1748-7161-7-3 · Cited by 585
Kluszczyński, M., Pilis, A., & Czaprowski, D. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04965-4 · Cited by 21
Metadata
- Authors
- Côté, P., Kreitz, B. G., Cassidy, J. D., Dzus, A. K., & Martel, J.
- Venue
- Spine
- Published
- 1998-04
- Volume
- 23
- Issue
- 7
- Pages
- 796-802
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2322050688
- Cited by
- 236
- References
- 1
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Study of the Diagnostic Accuracy and Reliability of the Scoliometer and Adamʼs Forward Bend Test. https://app.cochat.ai/papers/10.1097/00007632-199804010-00011
- The paper
- Côté, P., Kreitz, B. G., Cassidy, J. D., Dzus, A. K., & Martel, J. (1998). A Study of the Diagnostic Accuracy and Reliability of the Scoliometer and Adamʼs Forward Bend Test. Spine. https://doi.org/10.1097/00007632-199804010-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.