The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Reliability of the Isokinetic Trunk Extensor Test, Biering-Sørensen Test, and Åstrand Bicycle Test: Assessment of Intraclass Correlation Coefficient and Critical Difference in Patients With Chronic Low Back Pain and Healthy Individuals
Abstract
STUDY DESIGN: A reliability study was performed. OBJECTIVE: To determine the intersession reproducibility of the isokinetic trunk extensor strength test, the Biering-Sørensen test, and the Astrand test by calculation of the intraclass correlation coefficient and the critical difference. SUMMARY OF BACKGROUND DATA: Several physical measurements have been used in clinical evaluation of patients with chronic low back pain. Reliability can be evaluated by calculation of either intraclass correlation coefficient or critical difference, but interpretation of the results may vary depending on which method is used. METHODS: For this study, 31 patients with chronic low back pain carried out the isokinetic trunk extensor test, the Biering-Sørensen test, and the Astrand test as also did age- and gender-matched healthy individuals. Measurements were performed in three separate sessions at the same time of the day and by the same experienced examiner. The intervals between the sessions were 5 to 10 days. RESULTS: The isokinetic tests showed a learning effect between Tests 1 and 2. For the isokinetic test, the critical difference increased with increased angular velocities from 28% to 63% in the patients and from 27% to 39% in the healthy subjects. The critical differences for the patients and the healthy individuals were 57% vs 54% for the Biering-Sørensen test and 21% vs 23% for the Astrand test, respectively. The intraclass correlation coefficient ranged from 93% to 98% in the patients and 80%-98% in the healthy individuals. CONCLUSIONS: The reliability was found to be acceptable for the Astrand test and the isokinetic test at 60 degrees per second, as evaluated by the critical difference. All the tests were highly reliable according to the intraclass correlation coefficient, except for Biering-Sørensen test for healthy individuals. The critical difference is the preferable measure because calculation of the intraclass correlation coefficient may give a misleading high estimate of reliability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The test is reliable with respect to detecting changes in cardiorespiratory fitness [16].”
From Improved cardiorespiratory fitness after occupational rehabilitation in merged diagnostic groups (2018) · cites this paper as [34]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917
Waddell, G., Newton, M., Henderson, I., Somerville, D., & Main, C. J. (1993) · Pain · doi:10.1016/0304-3959(93)90127-b · Cited by 3,167
Clinical applications of visual analogue scales: a critical review
McCormack, H. M., Horne, D. J. D. L., & Sheather, S. J. (1988) · Psychological Medicine · doi:10.1017/s0033291700009934 · Cited by 2,108
Physical Measurements as Risk Indicators for Low-Back Trouble Over a One-Year Period
Biering‐Sørensen, F. (1984) · Spine · doi:10.1097/00007632-198403000-00002 · Cited by 1,376
Glüer, C.-C., Blake, G. M., Lü, Y., Blunt, B. A., Jergas, M. D., & Genant, H. K. (1995) · Osteoporosis International · doi:10.1007/bf01774016 · Cited by 1,282
Statistics Notes: Measurement error
Bland, J. M., & Altman, D. G. (1996) · BMJ · doi:10.1136/bmj.313.7059.744 · Cited by 1,084
Lumbar trunk muscle endurance testing: An inexpensive alternative to a machine for evaluation
Ito, T., Shirado, O., Suzuki, H., Takahashi, M., Kaneda, K., & Strax, T. E. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90224-5 · Cited by 337
Static back endurance and the risk of low-back pain
Luoto, S., Heliövaara, M., Hurri, H., & Alaranta, H. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00002-3 · Cited by 320
Comparing Two Methods of Clinical Measurement: A Personal History
Bland, J. M., & Altman, D. G. (1995) · International Journal of Epidemiology · doi:10.1093/ije/24.supplement_1.s7 · Cited by 297
L, S. J. S. (1983) · Journal of Rehabilitation Medicine · doi:10.2340/165019771983157179 · Cited by 294
Hultman, G., Nordin, M. C., Saraste, H., & n, H. O. (1993) · Journal of Spinal Disorders · doi:10.1097/00002517-199304000-00004 · Cited by 283
Non-dynamometric trunk performance tests: reliability and normative data
Alaranta, H., Hurri, H., Heliövaara, M., Soukka, A., & Harju, R. (1994) · Journal of Rehabilitation Medicine · doi:10.2340/165019771994264211215 · Cited by 200
Trunk Strength Testing with Iso-Machines
Newton, M., Thow, M., Somerville, D., Henderson, I., & Waddell, G. (1993) · Spine · doi:10.1097/00007632-199306000-00002 · Cited by 170
Risk indicators for low back trouble
Biering‐Sørensen, F., Thomsen, C. E., & Hilden, J. (1989) · Journal of Rehabilitation Medicine · doi:10.2340/165019771989151157 · Cited by 132
Predictors of Isokinetic Back Muscle Strength in Patients With Low Back Pain
Keller, A., JOHANSEN, J. G., Hellesnes, J., & Brox, J. I. (1999) · Spine · doi:10.1097/00007632-199902010-00016 · Cited by 100
Self-citationPhysical Fitness and Chronic Low Back Pain
McQuade, K. J., Turner, J. A., & Büchner, D. M. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198808000-00023 · Cited by 99
Some Endurance Measures in Persons With Chronic Low Back Pain
Moffroid, M. T., Reid, S., Henry, S. M., Haugh, L. D., & Ricamato, A. L. (1994) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1994.20.2.81 · Cited by 99
Physical Progress and Residual Impairment Quantification After Functional Restoration|Part I
Mayer, T. G., Tabor, J., Bovasso, E., & Gatchel, R. J. (1994) · Spine · doi:10.1097/00007632-199402001-00001 · Cited by 86
Reliability of Isokinetic Measurements of Trunk Muscle Performance
Delitto, A., Rose, S. J., Crandell, C. E., & Strube, M. J. (1991) · Spine · doi:10.1097/00007632-199107000-00019 · Cited by 82
Newton, M., & Waddell, G. (1991) · Physiotherapy · doi:10.1016/s0031-9406(10)61906-2 · Cited by 64
Biering‐Sørensen, F. (1983) · Journal of Rehabilitation Medicine · doi:10.2340/165019771983151116 · Cited by 61
The Reliability and Validity of a Physical Work Test
Borg, G. A. V., & DAHLSTRÖM, H. (1962) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1962.tb02449.x · Cited by 59
Ljungquist, T., Harms‐Ringdahl, K., Nygren, Å., & Jensen, I. B. (1999) · Physiotherapy Research International · doi:10.1002/pri.167 · Cited by 59
Trunk Extensor and Flexor Strength Measured by the Cybex 6000 Dynamometer
Madsen, O. R. (1996) · Spine · doi:10.1097/00007632-199612010-00012 · Cited by 57
Moffroid, M. T., Haugh, L. D., Henry, S. M., & Short, B. J. (1994) · Spine · doi:10.1097/00007632-199406000-00008 · Cited by 53
Cox, N. J. M., Hendriks, J. C. M., BINKHORST, R. A., Folgering, H. T. M., & van Herwaarden, C. L. A. (1989) · Lung · doi:10.1007/bf02714939 · Cited by 47
The Sock Test for Evaluating Activity Limitation in Patients With Musculoskeletal Pain
Strand, L. I., & Wie, S. L. (1999) · Physical Therapy · doi:10.1093/ptj/79.2.136 · Cited by 39
Vasikaran, S. D., McCloskey, E. V., Kahn, S., & Kanis, J. А. (1994) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329403100310 · Cited by 39
Becque, M. D., Katch, V. L., Marks, C., & Dyer, R. (1993) · International Journal of Sports Medicine · doi:10.1055/s-2007-1021167 · Cited by 34
Non-dynamometric trunk performance tests: reliability and normative data
Alaranta, H., Hurri, H., Heliövaara, M., et al. (1994) · Journal of Rehabilitation Medicine · doi:10.2340/1650197794211215 · Cited by 27
Research works printed but not linked: 3
- Friedlander, 1991, Research study, 14, 220
- Hupli, 1996, The effect of repetition on measurement of isokinetic performance capacity of trunk muscles among healthy controls two different groups of low back-pain patients Scand J Rehabil Med, 28, 201
- Kroll, 1963, Res Q, 34, 50
Cited by
Sorted by citations
Core Stability and Its Relationship to Lower Extremity Function and Injury
Willson, J. D., Dougherty, C. P., Ireland, M. L., & DAVIS, I. M. (2005) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200509000-00005 · Cited by 663
Brox, J. I., Sørensen, R., Friis, A., Nygaard, O. P., Indahl, A., Keller, A., Ingebrigtsen, T., Eriksen, H. R., Holm, I., Koller, A. K., et al. (2003) · Spine · doi:10.1097/01.brs.0000083234.62751.7a · Cited by 618
Self-citationSpinal muscle evaluation using the Sorensen test: a critical appraisal of the literature
Demoulin, C., Vanderthommen, M., Duysens, C., & Crielaard, J.-M. (2004) · Joint Bone Spine · doi:10.1016/j.jbspin.2004.08.002 · Cited by 305
Smeets, R., Köke, A. J. A., Lin, C. C., Ferreira, M. L., & Demoulin, C. (2011) · Arthritis Care & Research · doi:10.1002/acr.20542 · Cited by 283
May, S., Littlewood, C., & Bishop, A. (2006) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(06)70044-7 · Cited by 164
Metadata
- Authors
- Keller, A., Hellesnes, J., & Jens I. Brox, A.
- Affiliations
- Oslo University Hospital (NO)
- Corresponding author
- Keller, Anne
- Hellesnes, Jan
- Venue
- Spine
- Published
- 2001-04
- Volume
- 26
- Issue
- 7
- Pages
- 771-777
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1970531803
- Cited by
- 152
- References
- 31
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 2 · 2021: 4 · 2020: 10 · 2019: 2 · 2018: 2 · 2017: 7 · 2016: 6 · 2015: 3 · 2014: 9 · 2013: 8 · 2012: 10
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Spine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Musculoskeletal pain and rehabilitation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Spine and Intervertebral Disc Pathology
- Keywords
- test-retest reliability, chronic low back pain, critical difference, intraclass correlation coefficient, learning effects, angular velocity, trunk muscle strength
- MeSH terms
- Adult, Chronic Disease, Exercise Test, Female, Humans, Isometric Contraction, Male, Middle Aged, Muscles, Physical Endurance, Reproducibility of Results, Low Back Pain, Sex Distribution, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review