Interobserver and Intraobserver Reliability of the Japanese Orthopaedic Association Scoring System for Evaluation of Cervical Compression Myelopathy
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: The inter- and intraobserver reliabilities of an assessment scale for cervical compression myelopathy were examined statistically. This scoring system consists of seven categories: motor function of fingers, shoulder and elbow, and lower extremity; sensory function of upper extremity, trunk and lower extremity; and function of the bladder. It evaluates the severity of myelopathy by allocating points based on degree of dysfunction in each category. OBJECTIVES: To determine the inter- and intraobserver reliabilities of the revised scoring system (17 - 2 points) for cervical compression myelopathy proposed by the Japanese Orthopedic Association. SUMMARY OF BACKGROUND DATA: Several scales to assess clinical outcome from treatment of cervical compression myelopathy have been proposed. Most of these scales include items evaluated by observers. However, no system, including the Japanese Orthopedic Association scoring system, has yet been validated in terms of interobserver reliability. METHODS: From five different university hospitals, 10 spine surgery specialists, 10 orthopedic surgeons who had just passed the board examination of the Japanese Orthopedic Association, and 13 residents in the first or second year of orthopedic residency programs were chosen. The participants in this study were 29 patients with myelopathy secondary to ossification of the posterior longitudinal ligament selected from five participating university hospitals. Several surgeons interviewed each patient twice at intervals of 1 to 6 weeks. Inter- and intraobserver reliabilities of the total score for all categories were evaluated by the intraclass correlation coefficient. The extension of the kappa coefficient of Kraemer also was calculated for each category to assess reliability of multivariate categorical data. RESULTS: The interobserver reliability of the total score for the first interview (intraclass correlation coefficient = 0.813) and the intra- and interobserver reliabilities of the total score (intraclass correlation coefficient = 0.826) were high. The level of experience and the hospital slightly affected the reliability of the Japanese Orthopedic Association scoring system. The kappa values for intraobserver data generally were high in each category, whereas the kappa values for interobserver data were relatively low for the categories of shoulder-elbow motor function and lower extremity sensory function. CONCLUSIONS: The inter- and intraobserver reliabilities of the Japanese Orthopedic Association scoring system for cervical myelopathy were high, suggesting that this system is useful for assessment of cervical myelopathy in comparative studies of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE PATHOGENESIS OF THE SPINAL CORD DISORDER ASSOCIATED WITH CERVICAL SPONDYLOSIS
NURJCK, S. (1972) · Brain · doi:10.1093/brain/95.1.87 · Cited by 891
Cervical Laminectomy and Dentate Ligament Section for Cervical Spondylotic Myelopathy
Benzel, E. C., Lancon, J., Kesterson, L., & Hadden, T. (1991) · Journal of Spinal Disorders · doi:10.1097/00002517-199109000-00005 · Cited by 526
Natural History and Prognosis of Cervical Spondylosis
Lees, F., & Turner, J. W. A. (1963) · BMJ · doi:10.1136/bmj.2.5373.1607 · Cited by 418
Extension of the Kappa Coefficient
Kraemer, H. C. (1980) · Biometrics · doi:10.2307/2529972 · Cited by 237
Cervical Spondylotic Myelopathy: Surgical Results and Factors Affecting Prognosis
Naderi, S., Özgen, S., Pamir, M. N., Özek, M. M., & Erzen, C. (1998) · Neurosurgery · doi:10.1097/00006123-199807000-00028 · Cited by 158
Improving the reliability of orthopaedic measurements
Wright, J., & Feinstein, A. (1992) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.74b2.1544971 · Cited by 126
The surgical treatment of cervical spondylotic myelopathy
Symon, L., & Lavender, P. (1967) · Neurology · doi:10.1212/wnl.17.2.117 · Cited by 111
Long-Term Results of Surgical Treatment of Myelopathy Due to Cervical Spondylosis
Guidetti, B., & Fortuna, A. (1969) · Journal of neurosurgery · doi:10.3171/jns.1969.30.6.0714 · Cited by 110
Cited by
Degenerative cervical myelopathy — update and future directions
Badhiwala, J. H., Ahuja, C. S., Akbar, M. A., Witiw, C. D., Nassiri, F., Furlan, J. C., Curt, A., Wilson, J. R., & Fehlings, M. G. (2020) · Nature Reviews Neurology · doi:10.1038/s41582-019-0303-0 · Cited by 540
Kato, S., Oshima, Y., Oka, H., Chikuda, H., Takeshita, Y., Miyoshi, K., Kawamura, N., Masuda, K., Kunogi, J., Okazaki, R., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0123022 · Cited by 255
Baron, E. M., & Young, W. F. (2007) · Neurosurgery · doi:10.1227/01.neu.0000215383.64386.82 · Cited by 242
“It also has been demonstrated to have a high interobserver and intraobserver reliability (75).”
BackgroundNew MRI Grading System for the Cervical Canal Stenosis
Kang, Y., Lee, J. W., Koh, Y. H., Hur, S., Kim, S. J., Chai, J. W., & Kang, H. S. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5560 · Cited by 234
“However, further investigation based on elaborate assessment of symptoms, such as the Japanese Orthopedic Association score [24], is needed to elucidate the correlation between the grades and the severity of symptoms and the association of preoperative grades with outcome in patients undergoing surgical treatment.”
BackgroundNiki, H., Aoki, H., Inokuchi, S., Ozeki, S., Kinoshita, M., Kura, H., Tanaka, Y., Noguchi, M., Nomura, S., Hatori, M., et al. (2005) · Journal of Orthopaedic Science · doi:10.1007/s00776-005-0937-1 · Cited by 219
Patient-reported Outcome Measures in Spine Surgery
McCormick, J. D., Werner, B. C., & Shimer, A. L. (2013) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-21-02-99 · Cited by 218
“into three degrees: severe (score <9), moderate (score ranging from 9 to 13), and mild (score >13).(48) Yonenobu et al(48) found that the original scale had high inter- and intraobserver reliability.”
BackgroundMethodInfluentialTetreault, L., Nouri, A., Kopjar, B., Côté, P., & Fehlings, M. G. (2015) · Spine · doi:10.1097/brs.0000000000001127 · Cited by 193
“8 on the basis of the literature estimate of the JOA score.(11) A sensitivity analysis was performed using an estimate of 0.”
MethodPolyetheretherketone (PEEK) cages in cervical applications: a systematic review
Kersten, R. F. M. R., van Gaalen, S. M., de Gast, A., & Öner, F. C. (2015) · The Spine Journal · doi:10.1016/j.spinee.2013.08.030 · Cited by 177
“- VAS [44] - ODI [45] - Neck Disability Index (NDI) [46] - Japanese Orthopedic Association score (JOA score) [47] - Odom’s criteria [48] - Patients’ satisfaction by Likert scale [49] - Prolo scale [50] - The MOS 36-item short-form health survey (SF-36) [51–53]”
MethodHabekost, C. T., Schestatsky, P., Torres, V. F., de Coelho, D. M., Vargas, C. R., Torrez, V., Oses, J. P., Portela, L. V., Pereira, F. D. S., Matte, U., et al. (2014) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-9-6 · Cited by 35
“JOA was developed to follow cervical compression myelopathies [15], and it is probably the most used neurologic scale for myelopathies so far.”
Method
Metadata
- Authors
- Yonenobu, K., Abumi, K., Nagata, K., Taketomi, E., & Ueyama, K.
- Venue
- Spine
- Published
- 2001-09
- Volume
- 26
- Issue
- 17
- Pages
- 1890-1894
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2168477871
- Cited by
- 493
- References
- 8
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.