Saliva as a Valid Alternative to Serum in Monitoring Intravenous Caffeine Treatment for Apnea of Prematurity
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Caffeine is a potentially useful alternative to theophylline for the treatment and prevention of apnea of prematurity because of its lower toxicity and longer terminal half-life. Monitoring of salivary caffeine concentrations is less invasive than blood sampling, especially in very sick premature neonates. Caffeine citrate-3 mg/kg, 15 mg/kg, or 30 mg/kg-was administered once daily for 7 days in a randomized, parallel design to 59 newborn, premature infants with an initial loading dose of twice the maintenance dose. Serum and saliva samples (131 pairs) were collected and assayed by high-performance liquid chromatography (HPLC) for caffeine content. Measurable caffeine concentrations in serum ranged from 0.28 to 93.3 mg/L and in saliva from 0.35 to 91.5 mg/L. The mean ratio of the saliva-to-serum concentrations was 0.924. There was no significant difference in precision between the serum and salivary data. The mean serum caffeine concentration was 29.9 mg/L, and the mean salivary concentration was 27.7 mg/L, indicating a small negative bias for saliva versus serum monitoring. Salivary caffeine concentration monitoring is a satisfactory alternative to blood sampling across a wide range of caffeine doses used to treat apnea.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Caffeine in human milk and in serum of breast-fed infants
Ryu, J. E. (2017) · Developmental Pharmacology and Therapeutics · doi:10.1159/000457057 · Cited by 44
Cited by
Clinically Significant Pharmacokinetic Interactions Between Dietary Caffeine and Medications
Carrillo, J. A., & Benitez, J. (2000) · Clinical Pharmacokinetics · doi:10.2165/00003088-200039020-00004 · Cited by 364
(2006) · Pharmacology Biochemistry and Behavior · doi:10.1016/j.pbb.2006.03.005 · Cited by 213
“Compliance was assessed by capsule counts in bottles brought in on lab days, by caffeine assay of saliva specimens collected at home each day at 7:00 p.m. (Lee et al., 1996; Lelo et al., 1986; Zylber-Katz et al., 1984), and from saliva specimens collected each morning upon entering the lab.”
BackgroundMethodOn the Use of Caffeine as a Contrast Booster for BOLD fMRI Studies
Mulderink, T. A., Gitelman, D. R., Mesulam, M.-M., & Parrish, T. B. (2002) · NeuroImage · doi:10.1006/nimg.2001.0973 · Cited by 164
Effect of Caffeine on Aortic Elastic Properties and Wave Reflection
Vlachopoulos, C., Hirata, K., & O'Rourke, M. F. (2003) · Journal of Hypertension · doi:10.1097/00004872-200303000-00022 · Cited by 79
Periextubation caffeine in preterm neonates: a randomized dose response trial
Steer, P., Flenady, V., Shearman, A., Lee, T., Tudehope, D., & Charles, B. (2003) · Journal of Paediatrics and Child Health · doi:10.1046/j.1440-1754.2003.00207.x · Cited by 77
Metadata
- Authors
- Lee, T. C., Charles, B. G., Steer, P. A., & Flenady, V. J.
- Venue
- Therapeutic Drug Monitoring
- Published
- 1996-06
- Volume
- 18
- Issue
- 3
- Pages
- 288-293
- ISSN
- 0163-4356 (ISSN-L)
- OpenAlex
- W1989396412
- Cited by
- 43
- References
- 1
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.