CoChat

Saliva as a Valid Alternative to Serum in Monitoring Intravenous Caffeine Treatment for Apnea of Prematurity

Lee, Toong C., Charles, Bruce G., Steer, Peter A., Flenady, Vicki J. · 1996 · Therapeutic Drug Monitoring
Cited by 43

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Caffeine is a potentially useful alternative to theophylline for the treatment and prevention of apnea of prematurity because of its lower toxicity and longer terminal half-life. Monitoring of salivary caffeine concentrations is less invasive than blood sampling, especially in very sick premature neonates. Caffeine citrate-3 mg/kg, 15 mg/kg, or 30 mg/kg-was administered once daily for 7 days in a randomized, parallel design to 59 newborn, premature infants with an initial loading dose of twice the maintenance dose. Serum and saliva samples (131 pairs) were collected and assayed by high-performance liquid chromatography (HPLC) for caffeine content. Measurable caffeine concentrations in serum ranged from 0.28 to 93.3 mg/L and in saliva from 0.35 to 91.5 mg/L. The mean ratio of the saliva-to-serum concentrations was 0.924. There was no significant difference in precision between the serum and salivary data. The mean serum caffeine concentration was 29.9 mg/L, and the mean salivary concentration was 27.7 mg/L, indicating a small negative bias for saliva versus serum monitoring. Salivary caffeine concentration monitoring is a satisfactory alternative to blood sampling across a wide range of caffeine doses used to treat apnea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007691-199606000-00012

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 43

Metadata

Authors
Lee, T. C., Charles, B. G., Steer, P. A., & Flenady, V. J.
Venue
Therapeutic Drug Monitoring
Published
1996-06
Volume
18
Issue
3
Pages
288-293
ISSN
0163-4356 (ISSN-L)
OpenAlex
W1989396412
Cited by
43
References
1
FWCI
1.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.