CoChat

BONE FRACTURE AND OSTEODENSITOMETRY WITH DUAL ENERGY X-RAY ABSORPTIOMETRY IN KIDNEY TRANSPLANT RECIPIENTS

Grotz, Wolfgang H., Mundinger, F Alexander, Gugel, Bernd, Exner, Volkert, Kirste, Günter, Schollmeyer, Peter J. · 1994 · Transplantation
Cited by 213

The DOI matches its Crossref record.

Abstract

Kidney transplant recipients have multiple factors leading to osteoporosis. The purpose of this study was to determine the fracture rate after kidney transplantation and the significance of osteodensitometry with dual energy x-ray absorptiometry (DXA) in identifying the risk patients. Bone mineral density (BMD) was measured with DXA in 100 graft recipients (mean interval 63 +/- 53 months after transplantation) and correlated with the incidence of fractures. Fracture rate of peripheral bones increased from 0.009 before transplantation and 0.012 on hemodialysis to 0.032 fractures per patient and year after transplantation. Seventeen fractures of peripheral bones occurred in 11% of the patients within a mean of 103 +/- 59 months after transplantation. Three additional patients had fractures of the lumbar spine. Patients with fractures were characterized by low or low-normal BMD (0.93 +/- 0.23 versus 1.04 +/- 0.17 g/cm2 at lumbar spine), a frequent history of parathyroidectomy (21% versus 6%), and a longer transplant interval (103 +/- 59 versus 57 +/- 49 months). Fractures occurred in patients with low and normal BMD. DXA at the femoral neck proved to be of no value to define patients at risk of fractures. DXA at the lumbar spine also proved to be of limited value for this question. Therefore, alternatively, more sensitive methods of BMD and of bone architecture measurements are necessary for identifying the kidney transplant recipients at risk of fracture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007890-199410270-00009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 213

Metadata

Authors
Grotz, W. H., Mundinger, F. A., Gugel, B., Exner, V., Kirste, G., & Schollmeyer, P. J.
Venue
Transplantation
Published
1994-10
Volume
58
Issue
8
Pages
912-915
ISSN
0041-1337 (ISSN-L)
OpenAlex
W2074181554
Cited by
213
References
0
FWCI
5.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: BONE FRACTURE AND OSTEODENSITOMETRY WITH DUAL ENERGY X-RAY ABSORPTIOMETRY IN KIDNEY TRANSPLANT RECIPIENTS. https://app.cochat.ai/papers/10.1097/00007890-199410270-00009
The paper
Grotz, W. H., Mundinger, F. A., Gugel, B., Exner, V., Kirste, G., & Schollmeyer, P. J. (1994). BONE FRACTURE AND OSTEODENSITOMETRY WITH DUAL ENERGY X-RAY ABSORPTIOMETRY IN KIDNEY TRANSPLANT RECIPIENTS. Transplantation. https://doi.org/10.1097/00007890-199410270-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.