BONE FRACTURE AND OSTEODENSITOMETRY WITH DUAL ENERGY X-RAY ABSORPTIOMETRY IN KIDNEY TRANSPLANT RECIPIENTS
The DOI matches its Crossref record.
Abstract
Kidney transplant recipients have multiple factors leading to osteoporosis. The purpose of this study was to determine the fracture rate after kidney transplantation and the significance of osteodensitometry with dual energy x-ray absorptiometry (DXA) in identifying the risk patients. Bone mineral density (BMD) was measured with DXA in 100 graft recipients (mean interval 63 +/- 53 months after transplantation) and correlated with the incidence of fractures. Fracture rate of peripheral bones increased from 0.009 before transplantation and 0.012 on hemodialysis to 0.032 fractures per patient and year after transplantation. Seventeen fractures of peripheral bones occurred in 11% of the patients within a mean of 103 +/- 59 months after transplantation. Three additional patients had fractures of the lumbar spine. Patients with fractures were characterized by low or low-normal BMD (0.93 +/- 0.23 versus 1.04 +/- 0.17 g/cm2 at lumbar spine), a frequent history of parathyroidectomy (21% versus 6%), and a longer transplant interval (103 +/- 59 versus 57 +/- 49 months). Fractures occurred in patients with low and normal BMD. DXA at the femoral neck proved to be of no value to define patients at risk of fractures. DXA at the lumbar spine also proved to be of limited value for this question. Therefore, alternatively, more sensitive methods of BMD and of bone architecture measurements are necessary for identifying the kidney transplant recipients at risk of fracture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone metabolism and disease in chronic kidney disease
Eknoyan, G., Levin, A., & Levin, N. W. (2003) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(03)00905-3 · Cited by 1,286
Recommendations for the Outpatient Surveillance of Renal Transplant Recipients
KASISKE, B. L., VAZQUEZ, M. A., HARMON, W. E., BROWN, R. S., DANOVITCH, G. M., GASTON, R. S., ROTH, D., SCANDLING, J. D., & SINGER, G. G. (2000) · Journal of the American Society of Nephrology · doi:10.1681/asn.v11suppl_1s1 · Cited by 634
Incidence and long-term cost of steroid-related side effects after renal transplantation
Veenstra, D. L., Best, J. H., Hornberger, J., Sullivan, S. D., & Hricik, D. E. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70414-2 · Cited by 301
Osteoporosis after Organ Transplantation
Rodino, M. A., & Shane, E. (1998) · The American Journal of Medicine · doi:10.1016/s0002-9343(98)00081-3 · Cited by 249
Increased Risk of Fracture in Patients Receiving Solid Organ Transplants
Ramsey-Goldman, R., Dunn, J. E., Dunlop, D. D., Stuart, F. P., Abecassis, M. M., Kaufman, D. B., Langman, C. B., Salinger, M. H., & Sprague, S. M. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.3.456 · Cited by 248
“032 per year observed in an earlier study when 100 patients were followed a mean of 8 1/2 years.((10)) Thus, the combined data suggest that the rate of fracture may remain relatively constant over time after renal transplantation.”
BackgroundResultInfluential
Metadata
- Authors
- Grotz, W. H., Mundinger, F. A., Gugel, B., Exner, V., Kirste, G., & Schollmeyer, P. J.
- Venue
- Transplantation
- Published
- 1994-10
- Volume
- 58
- Issue
- 8
- Pages
- 912-915
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2074181554
- Cited by
- 213
- References
- 0
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: BONE FRACTURE AND OSTEODENSITOMETRY WITH DUAL ENERGY X-RAY ABSORPTIOMETRY IN KIDNEY TRANSPLANT RECIPIENTS. https://app.cochat.ai/papers/10.1097/00007890-199410270-00009
- The paper
- Grotz, W. H., Mundinger, F. A., Gugel, B., Exner, V., Kirste, G., & Schollmeyer, P. J. (1994). BONE FRACTURE AND OSTEODENSITOMETRY WITH DUAL ENERGY X-RAY ABSORPTIOMETRY IN KIDNEY TRANSPLANT RECIPIENTS. Transplantation. https://doi.org/10.1097/00007890-199410270-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.