The DOI matches its Crossref record.
REDUCED INTER- AND INTRASUBJECT VARIABILITY IN CYCLOSPORINE PHARMACOKINETICS IN RENAL TRANSPLANT RECIPIENTS TREATED WITH A MICROEMULSION FORMULATION IN CONJUNCTION WITH FASTING, LOW-FAT MEALS, OR HIGH-FAT MEALS1,2
Abstract
This cross-over study compared the pharmacokinetic parameters obtained from cyclosporine (CsA) concentration-time profiles after administration of the corn oil-based soft gel cap (CsA-GC) with those with the microemulsion (CsA-ME) gel cap. Neither the fasting state nor the coadministration of a low- or high-fat breakfast affected the pharmacokinetics of CsA presented in either formulation. Comparisons of the three sets of pharmacokinetic parameters--namely, after fasting or after low-fat or after high-fat diets--demonstrated the CsA-ME formulation to display greater intraindividual reproducibility of the C0 and C12 trough levels (TLs), Cmax, tmax, and area under the concentration-time curve (AUC) than the CsA-GC formulation. Although the degree of interindividual variation in AUC, Cmax and tmax after CsA-ME administration was slightly, but significantly, less than after CsA-GC administration, there was no difference between the two formulations in terms of the customarily monitored C0 or C12 TL values. CsA-ME showed higher correlation coefficients of drug exposure (AUC) with C12 than CsA-GC (0.910 versus 0.712). However, CsA-ME administration resulted in only modest improvement over CsA-GC administration in the relationships between drug dose and C0, C12, or AUC--namely, 0.645 versus 0.496, 0.611 versus 0.517, and 0.700 versus 0.501, respectively. Correlation analysis between individual timed samples and AUC determinations revealed that CsA-ME requires significantly less frequent blood monitoring for prediction of total drug exposure than does CsA-GC. Although the clinical utility of this reproducible pharmacokinetic behavior remains to be demonstrated in the de novo transplant setting, the markedly reduced intraindividual variation produced by administration of CsA-ME will likely improve the accuracy of pretransplant prediction of, and reduce the frequency of subsequent adjustments in, CsA doses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pouton, C. W. (2000) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(00)00167-6 · Cited by 1,230
Dunn, C. J., Wagstaff, A. J., Perry, C. M., Plosker, G. L., & Goa, K. L. (2001) · Drugs · doi:10.2165/00003495-200161130-00006 · Cited by 276
Borra, L. C. P., Roodnat, J. I., Kal, J. A., Mathot, R. A. A., Weimar, W., & van Gelder, T. (2010) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfq096 · Cited by 256
Review and analysis of FDA approved drugs using lipid-based formulations
Savla, R., Browne, J., Plassat, V., Wasan, K. M., & Wasan, E. K. (2017) · Drug Development and Industrial Pharmacy · doi:10.1080/03639045.2017.1342654 · Cited by 225
Metadata
- Authors
- Kahan, B. D., Dunn, J., Fitts, C., Van Buren, D., Wombolt, D., Pollak, R., Carson, R., Alexander, W. J., Choc, M., Wong, R., & Hwang, D. S.
- Venue
- Transplantation
- Published
- 1995-02
- Volume
- 59
- Issue
- 4
- Pages
- 505-511
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2049528226
- Cited by
- 215
- References
- 0
- FWCI
- 14.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: REDUCED INTER- AND INTRASUBJECT VARIABILITY IN CYCLOSPORINE PHARMACOKINETICS IN RENAL TRANSPLANT RECIPIENTS TREATED WITH A MICROEMULSION FORMULATION IN CONJUNCTION WITH FASTING, LOW-FAT MEALS, OR HIGH-FAT MEALS1,2. https://app.cochat.ai/papers/10.1097/00007890-199502270-00011
- The paper
- Kahan, B. D., Dunn, J., Fitts, C., Van Buren, D., Wombolt, D., Pollak, R., Carson, R., Alexander, W. J., Choc, M., Wong, R., & Hwang, D. S. (1995). REDUCED INTER- AND INTRASUBJECT VARIABILITY IN CYCLOSPORINE PHARMACOKINETICS IN RENAL TRANSPLANT RECIPIENTS TREATED WITH A MICROEMULSION FORMULATION IN CONJUNCTION WITH FASTING, LOW-FAT MEALS, OR HIGH-FAT MEALS1,2. Transplantation. https://doi.org/10.1097/00007890-199502270-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.