ASSOCIATION BETWEEN CAPSULE DIAMETER, ADEQUACY OF ENCAPSULATION, AND SURVIVAL OF MICROENCAPSULATED RAT ISLET ALLOGRAFTS1
The DOI matches its Crossref record.
Abstract
As a consequence of its large volume, a microencapsulated islet graft can be implanted only into the peritoneal cavity. The graft volume can be reduced by using small capsules. However, reduction of the diameter of the capsules holds a certain risk, because with smaller capsules, more islets may be found to protrude from the capsules. We have developed a lectin binding assay which, after encapsulation, specifically labels islets or parts of islets that are insufficiently immunoprotected as a consequence of inadequate, and particularly incomplete, encapsulation. With this assay, we found that a reduction of the capsule diameter from 800 micrometers to 500 micrometers was associated with an increase in the percentage of inadequately encapsulated islets from 6.3+/-1.2% to 24.2+/-1.5%. The in vivo significance of this finding was investigated by performing allotransplantations with large diameter (700-800 micrometers) and small diameter (400-500 micrometers) capsules. With large-capsule islet grafts, all recipients (n=5) became normoglycemic for 7-16 weeks, whereas with small-capsule islet grafts, only one of seven recipients became normoglycemic. The in vivo significance of inadequate encapsulation was further substantiated by our finding that most large capsules were floating freely in the peritoneal cavity without any cell adhesion, whereas the vast majority of small capsules was found to be adherent to the surface of intra-abdominal organs and infiltrated by immune cell elements characteristic of both an allograft reaction and a foreign body reaction. We conclude that successful use of capsules with small diameters requires further study to determine which factors in the encapsulation procedure should be modified to reduce the number of inadequate small capsules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Polyionic hydrocolloids for the intestinal delivery of protein drugs: alginate and chitosan—a review
George, M., & Abraham, T. E. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.04.017 · Cited by 2,012
Encapsulation for preservation of functionality and targeted delivery of bioactive food components
de Vos, P., Faas, M. M., Spasojevic, M., & Sikkema, J. (2010) · International Dairy Journal · doi:10.1016/j.idairyj.2009.11.008 · Cited by 786
Self-citationMartău, G. A., Mihai, M., & Vodnar, D. C. (2019) · Polymers · doi:10.3390/polym11111837 · Cited by 652
Natural polymers for the microencapsulation of cells
Gasperini, L., Mano, J. F., & Reis, R. L. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0817 · Cited by 602
Technology of mammalian cell encapsulation
Uludag, H., De Vos, P., & Tresco, P. A. (2000) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00053-3 · Cited by 601
Self-citation
Metadata
- Authors
- De Vos, P., De Haan, B., Pater, J., & Van Schilfgaarde, R.
- Venue
- Transplantation
- Published
- 1996-10
- Volume
- 62
- Issue
- 7
- Pages
- 893-899
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2082506451
- Cited by
- 149
- References
- 0
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ASSOCIATION BETWEEN CAPSULE DIAMETER, ADEQUACY OF ENCAPSULATION, AND SURVIVAL OF MICROENCAPSULATED RAT ISLET ALLOGRAFTS1. https://app.cochat.ai/papers/10.1097/00007890-199610150-00004
- The paper
- De Vos, P., De Haan, B., Pater, J., & Van Schilfgaarde, R. (1996). ASSOCIATION BETWEEN CAPSULE DIAMETER, ADEQUACY OF ENCAPSULATION, AND SURVIVAL OF MICROENCAPSULATED RAT ISLET ALLOGRAFTS1. Transplantation. https://doi.org/10.1097/00007890-199610150-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.