The DOI matches its Crossref record.
COMPLIANCE AND NONCOMPLIANCE IN PATIENTS WITH A FUNCTIONING RENAL TRANSPLANT: A MULTICENTER STUDY1,2
Abstract
BACKGROUND: Noncompliance with medication is a major cause of renal allograft failure among adult renal transplant patients. We summarize previous studies of noncompliance and report results of a large, multicenter survey designed to identify variables that (1) affect the likelihood of compliance with immunosuppressive medication regimens and (2) distinguish among noncompliant patients. METHODS: Questionnaires were distributed to 2500 patients at 56 U.S. transplant centers. Compliance was determined by patient responses to questions concerning whether, within the previous 4 weeks, one or more doses of immunosuppressive medications had been missed. Independent variables included patient and transplant characteristics, memories of dialysis, posttransplant symptoms and beliefs, and beliefs concerning the efficacy and importance of immunosuppressants. RESULTS: The incidence of noncompliance reported by the 1402 respondents was 22.4%. A logistic regression model that included age, occupation, time since transplant, and three medication-related beliefs was most predictive of the likelihood of compliance. Donor type and histories of diabetes and of infection entered the multivariate model when belief-related variables were excluded. Cluster analyses identified three distinct profiles of noncompliers: accidental noncompliers, invulnerables, and decisive noncompliers. CONCLUSIONS: Results of this study, which included nearly three times more patients than the largest previously reported study, can be used by clinicians to identify patients likely to become noncompliant, by researchers to develop randomized, prospective clinical trials of interventions designed to increase compliance, and by educators to tailor patient education programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Butler, J. A., Roderick, P., Mullee, M., Mason, J. C., & Peveler, R. C. (2004) · Transplantation · doi:10.1097/01.tp.0000110408.83054.88 · Cited by 541
Denhaerynck, K., Dobbels, F., Cleemput, I., Desmyttere, A., Schafer-Keller, P., Schaub, S., & De Geest, S. (2005) · Transplant International · doi:10.1111/j.1432-2277.2005.00176.x · Cited by 424
Canadian Society of Transplantation consensus guidelines on eligibility for kidney transplantation
Knoll, G. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.051291 · Cited by 376
Cukor, D., Rosenthal, D. S., Jindal, R. M., Brown, C. D., & Kimmel, P. L. (2009) · Kidney International · doi:10.1038/ki.2009.51 · Cited by 324
Rosenberger, J., Geckova, A. M., Dijk, J. P., Nagyova, I., Roland, R., Heuvel, W. J. A., & Groothoff, J. W. (2005) · Transplant International · doi:10.1111/j.1432-2277.2005.00183.x · Cited by 283
Metadata
- Authors
- Greenstein, S., & Siegal, B.
- Venue
- Transplantation
- Published
- 1998-12
- Volume
- 66
- Issue
- 12
- Pages
- 1718-1726
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2082206295
- Cited by
- 198
- References
- 0
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: COMPLIANCE AND NONCOMPLIANCE IN PATIENTS WITH A FUNCTIONING RENAL TRANSPLANT: A MULTICENTER STUDY1,2. https://app.cochat.ai/papers/10.1097/00007890-199812270-00026
- The paper
- Greenstein, S., & Siegal, B. (1998). COMPLIANCE AND NONCOMPLIANCE IN PATIENTS WITH A FUNCTIONING RENAL TRANSPLANT: A MULTICENTER STUDY1,2. Transplantation. https://doi.org/10.1097/00007890-199812270-00026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.