CoChat

Physical Activity Monitoring in Patients With Peripheral Arterial Occlusive Disease

Sieminski, Debra J., Cowell, Lynda L., Montgomery, Polly S., Pillai, Suresh B., Gardner, Andrew W. · 1997 · Journal of Cardiopulmonary Rehabilitation
Cited by 89

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: Physical activity is an important variable to measure in patients with peripheral arterial occlusive disease (PAOD) because of this relationship to cardiovascular disease morbidity and mortality. The purposes of this study were to (1) determine the reliability of measures of daily physical activity in PAOD participants using an accelerometer and a pedometer; and (2) assess the validity of both instruments by comparing them against validated physical activity questionnaires. METHODS: Forty-three patients with PAOD with a resting ankle/brachial index of 0.63 +/- 0.19 were monitored for 2 consecutive weekdays with an accelerometer and pedometer worn on each hip. The 48-hour monitoring period was repeated approximately 1 week later. RESULTS: The daily physical activity values obtained from the accelerometer were similar between the two testing periods, 352 +/- 248 kcal/day vs. 337 +/- 199 kcal/day; P = 0.61, with a reliability coefficient of r = 0.84. The steps obtained from the pedometer during each 2-day period also were similar, 4615 +/- 2839 steps/day vs. 4498 +/- 2768 steps /day; P = 0.75, with a reliability coefficient of r = 0.86. The physical activity values from the accelerometer moderately correlated with the Minnesota Leisure Time Physical Activity Questionnaire, r = 0.33; P < 0.01, and the NASA/Johnson Space Center Physical Activity Scale, r = 0.44; P < 0.001. Similarly, the relationship between the steps obtained from the pedometer and physical Activity and the Minnesota Leisure Time Physical Activity and NASA/Johnson Space Center Physical Activity Scale questionnaires were significant, r = 0.46 and r = 0.51; P < 0.001, respectively. CONCLUSION: These findings indicate that an accelerometer and pedometer are two instruments that reliably estimate the physical activity levels of patients with PAOD over 2 consecutive days. Furthermore, the activity questionnaires, suggesting that activity monitoring measures a different component of activities in patients with PAOD with intermittent claudication.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00008483-199701000-00006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 89

Metadata

Authors
Sieminski, D. J., Cowell, L. L., Montgomery, P. S., Pillai, S. B., & Gardner, A. W.
Venue
Journal of Cardiopulmonary Rehabilitation
Published
1997-01
Volume
17
Issue
1
Pages
43-47
ISSN
0883-9212 (ISSN-L)
OpenAlex
W2032467201
Cited by
89
References
1
FWCI
2.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physical Activity Monitoring in Patients With Peripheral Arterial Occlusive Disease. https://app.cochat.ai/papers/10.1097/00008483-199701000-00006
The paper
Sieminski, D. J., Cowell, L. L., Montgomery, P. S., Pillai, S. B., & Gardner, A. W. (1997). Physical Activity Monitoring in Patients With Peripheral Arterial Occlusive Disease. Journal of Cardiopulmonary Rehabilitation. https://doi.org/10.1097/00008483-199701000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.