Carotid Artery Stenosis: Grayscale and Doppler Ultrasound Diagnosis???Society of Radiologists in Ultrasound Consensus Conference

Grant, Edward G., Benson, Carol B., Moneta, Gregory L., Alexandrov, Andrei V., Baker, J. Dennis, Bluth, Edward I., Carroll, Barbara A., Eliasziw, Michael, Gocke, John, Hertzberg, Barbara S., Katarick, Sandra, Needleman, Laurence, Pellerito, John, Polak, Joseph F., Rholl, Kenneth S., Wooster, Douglas L., Zierler, Eugene·2003·Ultrasound Quarterly

Abstract

The Society of Radiologists in Ultrasound convened a multidisciplinary panel of experts in the field of vascular ultrasonography (US) to come to a consensus regarding Doppler US for assistance in the diagnosis of carotid artery stenosis. The panel's consensus statement is believed to represent a reasonable position on the basis of analysis of available literature and panelists' experience. Key elements of the statement include the following: First, all internal carotid artery (ICA) examinations should be performed with grayscale, color Doppler, and spectral Doppler US. Second, the degree of stenosis determined at grayscale and Doppler US should be stratified into the categories of normal (no stenosis), less than 50% stenosis, 50 to 69% stenosis, > or =70% stenosis to near occlusion, near occlusion, and total occlusion. Third, ICA peak systolic velocity (PSV) and the presence of plaque on grayscale and/or color Doppler images are primarily used in the diagnosis and grading of ICA stenosis. Two additional parameters (the ICA-to-common carotid artery PSV ratio and ICA end diastolic velocity) may also be used when clinical or technical factors raise concern that ICA PSV may not be representative of the extent of disease. Fourth, ICA should be diagnosed as normal when ICA PSV is less than 125 cm/second and no plaque or intimal thickening is visible, less than 50% stenosis when ICA PSV is less than 125 cm/second and plaque or intimal thickening is visible, 50 to 69% stenosis when ICA PSV is 125 to 230 cm/second and plaque is visible, > or =70% stenosis to near occlusion when ICA PSV is more than 230 cm/second and visible plaque and lumen narrowing are seen, near occlusion when there is a markedly narrowed lumen on color Doppler US, and total occlusion when there is no detectable patent lumen on grayscale US and no flow on spectral, power, and color Doppler US. Fifth, the final report should discuss velocity measurements and grayscale and color Doppler findings. Study limitations should be noted when they exist. The conclusion should state an estimated degree of ICA stenosis as reflected in these categories. The panel also considered various technical aspects of carotid US and methods for quality assessment, and identified several important unanswered questions meriting future research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00013644-200312000-00005

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 364

Metadata

Authors
Grant, E. G., Benson, C. B., Moneta, G. L., Alexandrov, A. V., Baker, J. D., Bluth, E. I., Carroll, B. A., Eliasziw, M., Gocke, J., Hertzberg, B. S., Katarick, S., Needleman, L., Pellerito, J., Polak, J. F., Rholl, K. S., Wooster, D. L., & Zierler, E.
Venue
Ultrasound Quarterly
Published
2003-12
Volume
19
Issue
4
Pages
190-198
ISSN
0894-8771 (ISSN-L)
OpenAlex
W2006069624
Cited by
364
References
19
FWCI
8.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Carotid Artery Stenosis: Grayscale and Doppler Ultrasound Diagnosis???Society of Radiologists in Ultrasound Consensus Conference. https://app.cochat.ai/papers/10.1097/00013644-200312000-00005
The paper
Grant, E. G., Benson, C. B., Moneta, G. L., Alexandrov, A. V., Baker, J. D., Bluth, E. I., Carroll, B. A., Eliasziw, M., Gocke, J., Hertzberg, B. S., Katarick, S., Needleman, L., Pellerito, J., Polak, J. F., Rholl, K. S., Wooster, D. L., & Zierler, E. (2003). Carotid Artery Stenosis: Grayscale and Doppler Ultrasound Diagnosis???Society of Radiologists in Ultrasound Consensus Conference. Ultrasound Quarterly. https://doi.org/10.1097/00013644-200312000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.