CoChat

Serum 7α-hydroxy-4-cholesten-3-one and selenohomocholyltaurine (SeHCAT) whole body retention in the assessment of bile acid induced diarrhoea

Brydon, William G., Nyhlin, Henry, Eastwood, Martin A., Merrick, Malcolm V. · 1996 · European Journal of Gastroenterology & Hepatology
Cited by 101

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To assess the reliability of serum 7 alpha-hydroxy-4-cholesten-3-one (7 alpha-3ox-C) in the differential diagnosis of bile acid induced diarrhoea by comparison with 75selenohomocholyltaurine whole body retention (SeHCAT WBR). DESIGN: One hundred and sixty-four patients with chronic diarrhoea were investigated prospectively in two centres (Edinburgh and Sweden) by two different tests which measure bile acid loss or synthesis: the SeHCAT test which measures the 7-day SeHCAT WBR and serum 7 alpha-3ox-C which reflects the rate of bile acid synthesis. RESULTS: Forty-six patients had SeHCAT WBR of less than 10% (19 with ileal disease or resection, nine with idiopathic bile acid induced diarrhoea and 18 with miscellaneous causes for bile acid induced diarrhoea). All patients with ileal or idiopathic disease showed a favorable response to treatment as did 13 of the miscellaneous group. Serum 7 alpha-3ox-C was raised in all subjects with ileal disease/resection, seven patients with idiopathic disease and all subjects in the miscellaneous group who responded to treatment. Sixteen out of 118 patients with SeHCAT WBR greater than or equal to 10% had raised serum 7 alpha-3ox-C. CONCLUSION: The positive predictive value of serum 7 alpha-3ox-C was 74%. The high negative predictive value (98%) of serum 7 alpha-3ox-C indicates the possible use of this test for excluding bile acid malabsorption in this population. All but two subjects who responded to treatment had raised serum 7 alpha-3ox-C concentrations. The possibility that the sensitivity of the test can be improved by repeat testing needs to be further investigated. There was a significant correlation between fractional catabolic rate (FCR) SeHCAT and serum 7 alpha-3ox-C (r = 0.63, P < 0.0001). Further data are required to validate the reference range in women over 70 years of age.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00042737-199602000-00005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 101

Metadata

Authors
Brydon, W. G., Nyhlin, H., Eastwood, M. A., & Merrick, M. V.
Venue
European Journal of Gastroenterology & Hepatology
Published
1996-02
Volume
8
Issue
2
Pages
117-124
ISSN
0954-691X (ISSN-L)
OpenAlex
W2059368667
Cited by
101
References
0
FWCI
1.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Serum 7α-hydroxy-4-cholesten-3-one and selenohomocholyltaurine (SeHCAT) whole body retention in the assessment of bile acid induced diarrhoea. https://app.cochat.ai/papers/10.1097/00042737-199602000-00005
The paper
Brydon, W. G., Nyhlin, H., Eastwood, M. A., & Merrick, M. V. (1996). Serum 7α-hydroxy-4-cholesten-3-one and selenohomocholyltaurine (SeHCAT) whole body retention in the assessment of bile acid induced diarrhoea. European Journal of Gastroenterology & Hepatology. https://doi.org/10.1097/00042737-199602000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.