Report of a collaborative trial to investigate the performance of the R5 enzyme linked immunoassay to determine gliadin in gluten-free food
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Analytical methods for measurements of gluten in the low level range of 20-200 ppm of gluten, as required for gluten-free food, have never been endorsed by the Codex Alimentarius. With the aim of investigating standardized and reliable methods for the detection of gliadin in food with detection limits lower than 200 ppm, as proposed by the Codex Alimentarius, the Working Group on Prolamin Analysis and Toxicity (WGPAT) coordinated a large collaborative study to validate a monoclonal antibody based ELISA, which uses an antibody (R5) against rye secalins. METHODS: Twelve food samples in which gliadin was present in the range of 0-168 ppm were analysed with two different commercially available R5 ELISA tests and a special extraction solvent, based on a reducing and a dissociating agent designed to extract heat denatured proteins. Twenty laboratories participated in this study. RESULTS: Recovery values ranged from 65 to 110% in general. The repeatability (RSDr) and reproducibility (RSDR) figures ranged between 13 and 25, resp. 23 and 47 for one test, and between 11 and 22, resp. 25 and 33 for the other. CONCLUSION: Both assays are comparable and robust. The repeatability and reproducibility data are in a range that is acceptable for ELISAs. Kits from both suppliers fulfilled performance criteria of regular ELISA methods, and it is shown that both ELISA kits guarantee a sensitivity of 1.5 ppm gliadin for gluten-free food.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Oslo definitions for coeliac disease and related terms
Ludvigsson, J. F., Leffler, D. A., Bai, J. C., Biagi, F., Fasano, A., Green, P. H. R., Hadjivassiliou, M., Kaukinen, K., Kelly, C. P., Leonard, J. N., et al. (2013) · Gut · doi:10.1136/gutjnl-2011-301346 · Cited by 1,721
Lindfors, K., Ciacci, C., Kurppa, K., Lundin, K. E. A., Makharia, G. K., Mearin, M. L., Murray, J. A., Verdu, E. F., & Kaukinen, K. (2019) · Nature Reviews Disease Primers · doi:10.1038/s41572-018-0054-z · Cited by 399
Cereals for developing gluten-free products and analytical tools for gluten detection
Rosell, C. M., Barro, F., Sousa, C., & Mena, M. C. (2014) · Journal of Cereal Science · doi:10.1016/j.jcs.2013.10.001 · Cited by 169
“This antibody is a monoclonal antibody (Valdés et al., 2003; Mendez et al., 2005) that reacts with the epitope QQPFP and other motifs such as QLPFP, LQPFP, and QQQFP present in coeliac-toxic sequences that occur repeatedly in gliadins, hordeins, and secalins being highly sensitive towards these…”
Ballabio, C., Uberti, F., Di Lorenzo, C., Brandolini, A., Penas, E., & Restani, P. (2011) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf2041824 · Cited by 55
Kasarda, D. D., Dupont, F. M., Vensel, W. H., Altenbach, S. B., Lopez, R., Tanaka, C. K., & Hurkman, W. J. (2008) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf801575s · Cited by 33
Metadata
- Authors
- M??ndez, E., Vela, C., Immer, U., & Janssen, F. W.
- Venue
- European Journal of Gastroenterology & Hepatology
- Published
- 2005-10
- Volume
- 17
- Issue
- 10
- Pages
- 1053-1063
- ISSN
- 0954-691X (ISSN-L)
- OpenAlex
- W2065403653
- Cited by
- 114
- References
- 0
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Report of a collaborative trial to investigate the performance of the R5 enzyme linked immunoassay to determine gliadin in gluten-free food. https://app.cochat.ai/papers/10.1097/00042737-200510000-00008
- The paper
- M??ndez, E., Vela, C., Immer, U., & Janssen, F. W. (2005). Report of a collaborative trial to investigate the performance of the R5 enzyme linked immunoassay to determine gliadin in gluten-free food. European Journal of Gastroenterology & Hepatology. https://doi.org/10.1097/00042737-200510000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.