The DOI matches its Crossref record.
Large Diurnal Fluctuations in Intraocular Pressure Are an Independent Risk Factor in Patients With Glaucoma
Abstract
PURPOSE: To study the risk associated with diurnal intraocular pressure (IOP) variations in patients with open-angle glaucoma. PATIENTS AND METHODS: Sixty-four patients (105 eyes) from the practices of two glaucoma specialists successfully performed home tonometry with a self-tonometer five times a day for 5 days. All patients had open-angle glaucoma and documented IOP below 25 mm Hg over a mean follow-up period of 5 years. Baseline status and time to progression of visual field loss were identified from the clinical charts. The level and variability of diurnal IOP obtained using home tonometry were characterized. Risk of progression was analyzed using a nonparametric time-to-event model, incorporating methods for correlated outcomes. RESULTS: Although mean home IOP and baseline office IOP were similar (16.4 +/- 3.6 mm Hg and 17.6 +/- 3.2 mm Hg, respectively), the average IOP range over the 5 days of home tonometry was 10.0 +/- 2.9 mm Hg. Baseline office IOP had no predictive value (relative hazard, 0.98). The diurnal IOP range and the IOP range over multiple days were significant risk factors for progression, even after adjusting for office IOP, age, race, gender, and visual field damage at baseline (relative hazards [95% confidence intervals], 5.69 [1.86, 17.35] and 5.76 [2.21, 14.98]). Eighty-eight percent of patients in the upper twenty-fifth percentile of IOP and 57% of patients in the lower twenty-fifth percentile progressed within 8 years. CONCLUSIONS: In patients with glaucoma with office IOP in the normal range, large fluctuations in diurnal IOP are a significant risk factor, independent of parameters obtained in the office. Fluctuations in IOP may be important in managing patients with glaucoma. Development of methods to control fluctuations in IOP may be warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Nouri-Mahdavi, K., Hoffman, D., Coleman, A. L., Liu, G., Li, G., Gaasterland, D., & Caprioli, J. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.02.017 · Cited by 704
Risk Factors for Glaucoma Onset and Progression
Coleman, A. L., & Miglior, S. (2008) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.08.006 · Cited by 540
Intraocular Pressure Fluctuation
Caprioli, J., & Coleman, A. L. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.10.031 · Cited by 505
Primary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Metadata
- Authors
- Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., & Lindenmuth, K.
- Venue
- Journal of Glaucoma
- Published
- 2000-04
- Volume
- 9
- Issue
- 2
- Pages
- 134-142
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W2323970533
- Cited by
- 901
- References
- 0
- FWCI
- 20.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large Diurnal Fluctuations in Intraocular Pressure Are an Independent Risk Factor in Patients With Glaucoma. https://app.cochat.ai/papers/10.1097/00061198-200004000-00002
- The paper
- Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., & Lindenmuth, K. (2000). Large Diurnal Fluctuations in Intraocular Pressure Are an Independent Risk Factor in Patients With Glaucoma. Journal of Glaucoma. https://doi.org/10.1097/00061198-200004000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.