Large Diurnal Fluctuations in Intraocular Pressure Are an Independent Risk Factor in Patients With Glaucoma
The DOI matches its Crossref record.
Abstract
PURPOSE: To study the risk associated with diurnal intraocular pressure (IOP) variations in patients with open-angle glaucoma. PATIENTS AND METHODS: Sixty-four patients (105 eyes) from the practices of two glaucoma specialists successfully performed home tonometry with a self-tonometer five times a day for 5 days. All patients had open-angle glaucoma and documented IOP below 25 mm Hg over a mean follow-up period of 5 years. Baseline status and time to progression of visual field loss were identified from the clinical charts. The level and variability of diurnal IOP obtained using home tonometry were characterized. Risk of progression was analyzed using a nonparametric time-to-event model, incorporating methods for correlated outcomes. RESULTS: Although mean home IOP and baseline office IOP were similar (16.4 +/- 3.6 mm Hg and 17.6 +/- 3.2 mm Hg, respectively), the average IOP range over the 5 days of home tonometry was 10.0 +/- 2.9 mm Hg. Baseline office IOP had no predictive value (relative hazard, 0.98). The diurnal IOP range and the IOP range over multiple days were significant risk factors for progression, even after adjusting for office IOP, age, race, gender, and visual field damage at baseline (relative hazards [95% confidence intervals], 5.69 [1.86, 17.35] and 5.76 [2.21, 14.98]). Eighty-eight percent of patients in the upper twenty-fifth percentile of IOP and 57% of patients in the lower twenty-fifth percentile progressed within 8 years. CONCLUSIONS: In patients with glaucoma with office IOP in the normal range, large fluctuations in diurnal IOP are a significant risk factor, independent of parameters obtained in the office. Fluctuations in IOP may be important in managing patients with glaucoma. Development of methods to control fluctuations in IOP may be warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Nouri-Mahdavi, K., Hoffman, D., Coleman, A. L., Liu, G., Li, G., Gaasterland, D., & Caprioli, J. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.02.017 · Cited by 704
Risk Factors for Glaucoma Onset and Progression
Coleman, A. L., & Miglior, S. (2008) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.08.006 · Cited by 540
Intraocular Pressure Fluctuation
Caprioli, J., & Coleman, A. L. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.10.031 · Cited by 505
Primary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Parrish, R. K., Palmberg, P., & Sheu, W.-P. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00098-9 · Cited by 473
Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial
Bengtsson, B., Leske, M. C., Hyman, L., & Heijl, A. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.07.060 · Cited by 454
Twenty-four-Hour Intraocular Pressure Pattern Associated with Early Glaucomatous Changes
Liu, J. H. K., Zhang, X., Kripke, D. F., & Weinreb, R. N. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0666 · Cited by 444
Glaucoma history and risk factors
McMonnies, C. W. (2017) · Journal of Optometry · doi:10.1016/j.optom.2016.02.003 · Cited by 412
Risk Factors for Visual Field Progression in Treated Glaucoma
De Moraes, C. G. V. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2011.72 · Cited by 356
Current management of glaucoma
Lusthaus, J., & Goldberg, I. (2019) · Medical Journal of Australia · doi:10.5694/mja2.50020 · Cited by 354
Current understanding of conventional outflow dysfunction in glaucoma
Stamer, W. D., & Acott, T. S. (2012) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e32834ff23e · Cited by 320
What Is the Present Pathogenetic Concept of Glaucomatous Optic Neuropathy?
Flammer, J., & Mozaffarieh, M. (2007) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2007.08.012 · Cited by 316
The primary vascular dysregulation syndrome: implications for eye diseases
Flammer, J., Konieczka, K., & Flammer, A. J. (2013) · EPMA Journal · doi:10.1186/1878-5085-4-14 · Cited by 313
Aqueous outflow - A continuum from trabecular meshwork to episcleral veins
Carreon, T., van der Merwe, E., Fellman, R. L., Johnstone, M., & Bhattacharya, S. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.004 · Cited by 312
Oxidative deoxyribonucleic acid damage in the eyes of glaucoma patients
Izzotti, A., Saccà, S. C., Cartiglia, C., & De Flora, S. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00114-1 · Cited by 305
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
“Numerous recent prospective and retrospective articles (Rota-Bartelink et al. 1996; Graham & Drance 1999; Pointer 1999; Asrani et al. 2000; Liu 2001; Wax et al. 2002; Hughes et al. 2003; Denis 2004; Wilensky 2004; Blaise & Guillaume 2005; Barkana et al. 2006) have pointed out that 24-hr IOP…”
BackgroundBarkana, Y. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.6.793 · Cited by 278
Chen, P.-J., Saati, S., Varma, R., Humayun, M. S., & Tai, Y.-C. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2049825 · Cited by 264
Understanding mechanisms of pressure-induced optic nerve damage
Morrison, J. C., Johnson, E. C., Cepurna, W., & Jia, L. (2005) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2004.08.003 · Cited by 261
Ocular perfusion pressure in glaucoma
Costa, V. P., Harris, A., Anderson, D., Stodtmeister, R., Cremasco, F., Kergoat, H., Lovasik, J., Stalmans, I., Zeitz, O., Lanzl, I., et al. (2014) · Acta Ophthalmologica · doi:10.1111/aos.12298 · Cited by 255
Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors
Chen, P.-J., Rodger, D. C., Saati, S., Humayun, M. S., & Tai, Y.-C. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.2004945 · Cited by 251
“, daily) tracking, which impedes prompt detection and appropriate treatment for IOP spikes from its diurnal fluctuations considered as a separate risk factor to optic nerve damage [2]–[4].”
BackgroundFirst steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0015 · Cited by 244
Risk Factors and Open-angle Glaucoma: Classification and Application
Boland, M. V., & Quigley, H. A. (2007) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31806540a1 · Cited by 235
“Greater fluctuation in IOP under treatment was a better predictor of past progression than office-based IOP, adjusting for other risk factors.(32) Daugeliene et al.”
MethodRisk factors for open-angle glaucoma:
Kaimbo, D. K. W., Buntinx, F., & Missotten, L. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(00)00291-2 · Cited by 232
Mansouri, K., & Shaarawy, T. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.192922 · Cited by 232
“5 IOP fluctuation has been recognised as an independent risk factor for progression.(6) However, even medically and surgically controlled patients show significant IOP fluctuations throughout the day and on provocative testing.”
Background24-hour monitoring of intraocular pressure in glaucoma management: a retrospective review
Hughes, E., Spry, P., & Diamond, J. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.10.008 · Cited by 216
An evidence-based assessment of risk factors for the progression of ocular hypertension and glaucoma
Friedman, D. S., Wilson, M. R., Liebmann, J. M., Fechtner, R. D., & Weinreb, R. N. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.04.058 · Cited by 203
One-Year, Randomized Study Comparing Bimatoprost and Timolol in Glaucoma and Ocular Hypertension
Higginbotham, E. J. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.10.1286 · Cited by 199
Why Do People (Still) Go Blind from Glaucoma?
Susanna, R., De Moraes, C. G., Cioffi, G. A., & Ritch, R. (2015) · Translational Vision Science & Technology · doi:10.1167/tvst.4.2.1 · Cited by 198
Sherwood, M., & Brandt, J. (2001) · Survey of Ophthalmology · doi:10.1016/s0039-6257(01)00219-3 · Cited by 197
Meta-analysis of 24-Hour Intraocular Pressure Studies Evaluating the Efficacy of Glaucoma Medicines
Stewart, W. C., Konstas, A. G. P., Nelson, L. A., & Kruft, B. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.10.004 · Cited by 190
Management of Glaucoma: Focus on Pharmacological Therapy
Marquis, R. E., & Whitson, J. T. (2005) · Drugs & Aging · doi:10.2165/00002512-200522010-00001 · Cited by 187
Katz, L. J., Steinmann, W. C., Kabir, A., Molineaux, J., Wizov, S. S., & Marcellino, G. (2012) · Journal of Glaucoma · doi:10.1097/ijg.0b013e318218287f · Cited by 184
Oliver, J. E., Hattenhauer, M. G., Herman, D., Hodge, D. O., Kennedy, R., Fang-Yen, M., & Johnson, D. H. (2002) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)01403-4 · Cited by 181
Mansouri, K., Medeiros, F. A., Tafreshi, A., & Weinreb, R. N. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2012.2280 · Cited by 180
Miglior, S., Torri, V., Zeyen, T., Pfeiffer, N., Vaz, J. C., & Adamsons, I. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.04.040 · Cited by 172
Prata, T. S., De Moraes, C. G. V., Kanadani, F. N., Ritch, R., & Paranhos, A. (2010) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2009.12.002 · Cited by 159
“diurnal IOP fluctuation is greater in glaucomatous patients than normal patients and seems to be a significant risk factor for disease progression.(4,94,97) Although diurnal IOP fluctuation has been extensively studied in normal and glaucomatous patients,(17,39,57,67,92) its mechanism is still unclear.”
Fogagnolo, P., Orzalesi, N., Ferreras, A., & Rossetti, L. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2889 · Cited by 75
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Whitcup, S. M. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.1.57 · Cited by 67
“Large fluctuations in diurnal IOP are a risk factor for the progression of open angle glaucoma, 20 and IOP must be controlled throughout the day to minimise optic nerve damage.”
BackgroundLaukhin, V., Sánchez, I., Moya, A., Laukhina, E., Martin, R., Ussa, F., Rovira, C., Guimera, A., Villa, R., Aguiló, J., et al. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.05.021 · Cited by 57
Noninvasive intraocular pressure monitoring: Current insights
De Smedt, S. (2015) · Clinical ophthalmology · doi:10.2147/opth.s53772 · Cited by 29
Metadata
- Authors
- Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., & Lindenmuth, K.
- Venue
- Journal of Glaucoma
- Published
- 2000-04
- Volume
- 9
- Issue
- 2
- Pages
- 134-142
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W2323970533
- Cited by
- 901
- References
- 0
- FWCI
- 20.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.