CoChat

Urinary acetoacetate or capillary ??-hydroxybutyrate for the diagnosis of ketoacidosis in the Emergency Department setting

Taboulet, Pierre, Haas, Laurent, Porcher, Raphael, Manamani, Jaffar, Fontaine, Jean-Paul, Feugeas, Jean-Paul, Gautier, Jean-Francois · 2004 · European Journal of Emergency Medicine
Cited by 66

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: We compared the semiquantitative measurement of acetoacetate using urinary dipsticks with the bedside quantitative fingerprick measurement of the principal ketone bodies 3-beta-hydroxybutyrate, for the diagnosis of ketoacidosis. METHODS: This is a one year retrospective study of patients who presented with hyperglycemia levels of 250 mg/l or greater in the Emergency Department setting. We compared the sensitivity, specificity, and predictive value of ketonuria and ketonemia for the diagnosis of ketoacidosis (urine or blood ketone bodies, blood bicarbonates <20 mmol/l, anion gap >16 meq/l) in a sample of patients for whom the levels of ketone bodies in the blood and urine as well as serum electrolytes were available. RESULTS: We studied 355 hyperglycemic patients. The median time between arrival and dipstick testing was 21 min, and was greater than 2 h in more than 10% of cases. Comparison between ketonuria and ketonemia was performed in 173 patients (6% with diabetic ketoacidosis). Ketonuria equal to or less than one cross or a 3-beta-hydroxybutyrate value lower than 3 mmol/l enabled ketoacidosis to be excluded (negative predictive value 100%). At two-cross cutoff points for ketonuria and at the 3 mmol/l cutoff point for ketonemia, the two tests had the same sensitivity (100%), but the specificity of 3-beta-hydroxybutyrate (94%) was significantly higher (P<0.0001) than that of ketonuria (77%). The best positive predictive value for ketonemia was obtained at the 5 mmol/l cutoff point (100%) and for ketonuria at the three-cross cutoff point (26%). At the three-cross cutoff point for ketonuria and at the 5 mmol/l cutoff point for ketonemia, the two tests had the same negative likelihood ratio (0.1), but the positive likelihood ratio of 3-beta-hydroxybutyrate (infinite) was higher than that of ketonuria. CONCLUSION: The measurement of 3-beta-hydroxybutyrate in capillary blood is faster and more effective than the use of dipsticks in the urine to detect ketoacidosis in the Emergency Department setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00063110-200410000-00003

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 66

Metadata

Authors
Taboulet, P., Haas, L., Porcher, R., Manamani, J., Fontaine, J.-P., Feugeas, J.-P., & Gautier, J.-F.
Venue
European Journal of Emergency Medicine
Published
2004-10
Volume
11
Issue
5
Pages
251-258
ISSN
0969-9546 (ISSN-L)
OpenAlex
W2048569418
Cited by
66
References
8
FWCI
1.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Urinary acetoacetate or capillary ??-hydroxybutyrate for the diagnosis of ketoacidosis in the Emergency Department setting. https://app.cochat.ai/papers/10.1097/00063110-200410000-00003
The paper
Taboulet, P., Haas, L., Porcher, R., Manamani, J., Fontaine, J.-P., Feugeas, J.-P., & Gautier, J.-F. (2004). Urinary acetoacetate or capillary ??-hydroxybutyrate for the diagnosis of ketoacidosis in the Emergency Department setting. European Journal of Emergency Medicine. https://doi.org/10.1097/00063110-200410000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.