The DOI matches its Crossref record; 111 of the 111 references it cites were found in a registry or an index.
Progress in SIFT‐MS: Breath analysis and other applications
Abstract
The development of selected ion flow tube mass spectrometry, SIFT‐MS, is described from its inception as the modified very large SIFT instruments used to demonstrate the feasibility of SIFT‐MS as an analytical technique, towards the smaller but bulky transportable instruments and finally to the current smallest Profile 3 instruments that have been located in various places, including hospitals and schools to obtain on‐line breath analyses. The essential physics and engineering principles are discussed, which must be appreciated to design and construct a SIFT‐MS instrument. The versatility and sensitivity of the Profile 3 instrument is illustrated by typical mass spectra obtained using the three precursor ions H 3 O+, NO+ and ${\rm O}_{{\rm 2}}^{{\rm + } \cdot }$, and the need to account for differential ionic diffusion and mass discrimination in the analytical algorithms is emphasized to obtain accurate trace gas analyses. The performance of the Profile 3 instrument is illustrated by the results of several pilot studies, including (i) on‐line real time quantification of several breath metabolites for cohorts of healthy adults and children, which have provided representative concentration/population distributions, and the comparative analyses of breath exhaled via the mouth and nose that identify systemic and orally‐generated compounds, (ii) the enhancement of breath metabolites by drug ingestion, (iii) the identification of HCN as a marker of Pseudomonas colonization of the airways and (iv) emission of volatile compounds from urine, especially ketone bodies, and from skin. Some very recent developments are discussed, including the quantification of carbon dioxide in breath and the combination of SIFT‐MS with GC and ATD, and their significance. Finally, prospects for future SIFT‐MS developments are alluded to. © 2010 Wiley Periodicals, Inc., Mass Spec Rev 30:236–267, 2011
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Self-citationProton-Transfer Reaction Mass Spectrometry
Blake, R. S., Monks, P. S., & Ellis, A. M. (2009) · Chemical Reviews · doi:10.1021/cr800364q · Cited by 745
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Detection of Lung Cancer With Volatile Markers in the Breatha
Phillips, M., Cataneo, R. N., Cummin, A. R. C., Gagliardi, A. J., Gleeson, K., Greenberg, J., Maxfield, R. A., & Rom, W. N. (2003) · Chest · doi:10.1378/chest.123.6.2115 · Cited by 567
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Self-citationThe diagnostic potential of breath analysis.
Manolis, A. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.5 · Cited by 399
The selected ion flow tube (SIFT); A technique for studying ion-neutral reactions
Adams, N. G., & Smith, D. (1976) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(76)80133-7 · Cited by 397
Self-citation
Cited by
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Clinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Sethi, S., Nanda, R., & Chakraborty, T. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-13 · Cited by 331
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Metadata
- Authors
- Španěl, P., & Smith, D.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2011-02-17
- Volume
- 30
- Issue
- 2
- Pages
- 236-267
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2105673592
- Cited by
- 336
- References
- 111
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progress in SIFT‐MS: Breath analysis and other applications. https://app.cochat.ai/papers/10.1002/mas.20303
- The paper
- Španěl, P., & Smith, D. (2011). Progress in SIFT‐MS: Breath analysis and other applications. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.20303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.