Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 242

The DOI matches its Crossref record.

Central venous oxygen saturation monitoring in the critically ill patient

Rivers, Emanuel P., Ander, Douglas S., Powell, Doris · 2001 · Current Opinion in Critical Care

Abstract

In the initial treatment of a critically ill patient, blood pressure, heart rate, urine output, and central venous pressure guide resuscitative efforts. Despite normalization of these variables, global tissue hypoxia may still persist and has been implicated in the development of multiorgan failure and increased mortality. Definitive management includes intensive care unit admission, pulmonary artery catheterization using mixed venous oxygen saturation (SvO2), and hemodynamic optimization. In the absence of or before definitive management, hemodynamic optimization can be performed using central venous oxygen saturation (ScvO2) as a surrogate. The physiology, technology, clinical uses, and rationale for ScvO2 monitoring are reviewed, including issues regarding physiologic equivalence to SvO2. The clinical use of ScvO2 monitoring, evidence-based outcome implications, and limitations of ScvO2 monitoring will also be examined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00075198-200106000-00011

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 242

Metadata

Authors
Rivers, E. P., Ander, D. S., & Powell, D.
Venue
Current Opinion in Critical Care
Published
2001-06
Volume
7
Issue
3
Pages
204-211
ISSN
1070-5295 (ISSN-L)
OpenAlex
W1969162117
Cited by
242
References
0
FWCI
5.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Central venous oxygen saturation monitoring in the critically ill patient. https://app.cochat.ai/papers/10.1097/00075198-200106000-00011
The paper
Rivers, E. P., Ander, D. S., & Powell, D. (2001). Central venous oxygen saturation monitoring in the critically ill patient. Current Opinion in Critical Care. https://doi.org/10.1097/00075198-200106000-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.