Determinants of Seizure Threshold in ECT: Benzodiazepine Use, Anesthetic Dosage, and Other Factors
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The electrical dosage of the ECT stimulus impacts on efficacy and cognitive side effects, yet seizure threshold (ST) may vary as much as 50-fold across patients. It would be desirable to predict ST on the basis of patient and treatment characteristics. In particular, concerns have been raised that benzodiazepine use and higher dosage of barbiturate anesthetics elevate ST. In a three-site study, ST was quantified at the first ECT session using an identical empirical titration procedure in 294 patients who met RDC and DSM-IIIR criteria for a major depressive episode. ST varied over a 35-fold range across patients treated with right unilateral (RUL) (n = 267) and bilateral (BL) (n = 27) ECT. Higher ST was associated with BL electrode placement (p = 0.001). Among patients treated with RUL ECT, univariate analyses indicated that higher ST was associated with advanced age (p < 0.001), male gender (p < 0.001), greater burden of medical illness (p < 0.001), weight (p < 0.01), duration of mood disorder (p < 0.01), and history of previous ECT (p < 0.05). Average lorazepam dose in the 48 hours prior to ECT was not associated with ST, but was associated with decreased seizure duration (p < 0.01). Absolute, but not weight-adjusted, methohexital dose was associated with ST (p < 0.01). Multivariate analyses in patients treated with unilateral ECT showed that only 27.6% of the variance in ST (p < 0.0001) could be predicted. In the multivariate analyses, only age (p = 0.0001), gender (p = 0.01), and methohexital dose (p = 0.0001) were independently related to ST. Low dosage of lorazepam and methohexital dosage below 1 mg/kg are unlikely to impact on ST. Given the limited capacity to predict ST, empirical titration remains the only accurate method to determine electrical dosage in RUL ECT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, M. D., Paradis, C. F., Houck, P. R., Mazumdar, S., Stack, J. A., Rifai, A. H., Mulsant, B., & Reynolds, C. F. (1992) · Psychiatry Research · doi:10.1016/0165-1781(92)90005-n · Cited by 1,990
Self-citationFormula Method for Stimulus Setting in Bilateral Electroconvulsive Therapy: Relevance of Age
Gangadhar, B. N., Girish, K., Janakiramiah, N., Subbakrishna, D. K., Parameshwara, G., & Prasad, K. M. R. (1998) · The Journal of ECT · doi:10.1097/00124509-199812000-00008 · Cited by 23
Cited by
Sackeim, H. A., Prudic, J., Devanand, D. P., Nobler, M. S., Lisanby, S. H., Peyser, S., Fitzsimons, L., Moody, B. J., & Clark, J. (2000) · Archives of General Psychiatry · doi:10.1001/archpsyc.57.5.425 · Cited by 804
Self-citationLong‐term amygdalohippocampal stimulation for refractory temporal lobe epilepsy
Vonck, K., Boon, P., Achten, E., De Reuck, J., & Caemaert, J. (2002) · Annals of Neurology · doi:10.1002/ana.10323 · Cited by 295
Anesthesia for Electroconvulsive Therapy
Ding, Z., & White, P. F. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200205000-00057 · Cited by 228
“Although the administration of lorazepam before ECT was not associated with a change in the seizure threshold, the seizure duration was significantly decreased (52).”
BackgroundElectroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
“Conventionally, the stimulus dose is controlled by adjusting the number of pulses in the train by changing either the train duration or frequency; in some cases, the PW is modified as well.(11) The current amplitude is conventionally held fixed at the device maximum (eg, 800 or 900 mA).”
BackgroundSelf-citationTrajectories of Response to Dorsolateral Prefrontal rTMS in Major Depression: A THREE-D Study
Kaster, T. S., Downar, J., Vila-Rodriguez, F., Thorpe, K. E., Feffer, K., Noda, Y., Giacobbe, P., Knyahnytska, Y., Kennedy, S. H., Lam, R. W., et al. (2019) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2018.18091096 · Cited by 168
Metadata
- Authors
- Boylan, L. S., Haskett, R. F., Mulsant, B. H., Greenberg, R. M., Prudic, J., Spicknall, K., Lisanby, S. H., & Sackeim, H. A.
- Venue
- The Journal of ECT
- Published
- 2000-03
- Volume
- 16
- Issue
- 1
- Pages
- 3-18
- ISSN
- 1095-0680 (ISSN-L)
- OpenAlex
- W1969192109
- Cited by
- 123
- References
- 2
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.