CoChat

Optimizing cuff width for noninvasive measurement of blood pressure

Marks, Lloyd A., Groch, Anthony · 2000 · Blood Pressure Monitoring
Cited by 82

The DOI matches its Crossref record.

Abstract

BACKGROUND: It is well established that indirect measurements of blood pressure made with a standard 13cm-wide cuff are erroneously high for large arms and low for small arms. To correct for this error, the American Heart Association recommends adjusting cuff width to 40% of the arm's circumference. OBJECTIVE: To test the validity of this method of correction. DESIGN: This study was a prospective, nonblinded, paired Student's t-test analysis. METHODS: Blood pressures in 50 subjects were measured directly by using a radial artery line and indirectly by the Korotkov method. For each subject multiple indirect measurements of blood pressure were made with the cuff width:arm circumference ratio varied from 30-55% in 5% increments. Error was defined as indirect blood pressure minus direct blood pressure. RESULTS: A ratio of 40% resulted in overestimation of blood pressure for most arms and with particularly high errors for small arms. The ratio producing zero mean error for the pooled study group was 46.4+/-0.7% (mean+/-SEM). Using this ratio of 46.4%, the error varied inversely with arm circumference (P<0.02), resulting in overestimation of systolic blood pressure for small arms and underestimation of systolic blood pressure for large arms. This error is comparable in magnitude, but opposite in sign, to that which occurs with a standard 13cm-wide cuff for all arms. The optimum ratio was found to be closely approximated by the relationship, cuff width=9.34 log(10) arm circumference. Using this relationship, error in systolic blood pressure was insensitive to arm circumference (r=0.04, P>0.05) and near zero. CONCLUSION: The optimum cuff width for the indirect measurement of blood pressure is not directly proportional to arm circumference, but is proportional to the logarithm of the arm's circumference.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200006000-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 82

Metadata

Authors
Marks, L. A., & Groch, A.
Venue
Blood Pressure Monitoring
Published
2000-06
Volume
5
Issue
3
Pages
153-158
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2033294948
Cited by
82
References
0
FWCI
0.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimizing cuff width for noninvasive measurement of blood pressure. https://app.cochat.ai/papers/10.1097/00126097-200006000-00002
The paper
Marks, L. A., & Groch, A. (2000). Optimizing cuff width for noninvasive measurement of blood pressure. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200006000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.