Reliability of nocturnal blood pressure dipping
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Increasing evidence documents the fact that individuals whose blood pressure drops or 'dips' relatively little at night have a higher risk of numerous cardiovascular illnesses. OBJECTIVE: To examine the reliability of various measures of nocturnal blood pressure dipping. METHODS: This study examined 17 individuals with ambulatory blood pressure monitoring on three 24 h recordings while they pursued a schedule similar to that of in-patients on a clinical research unit. Nocturnal dipping of blood pressure was scored three ways: as the drop in blood pressure between 10 p.m. and 6 a.m. ('clocktime'), as the drop in blood pressure tailored to each individual's reported bedtime ('bedtime'), and as the drop in blood pressure accompanying polysomnographically verified sleep ('sleeptime'). RESULTS: Adequate reliability was obtained for all three measures of dipping. There was, in general, a significant correlation across testing occasions (P<0.05). The correlation coefficient ranged from 0.5 to 0.8, depending on which criterion of dipping was selected and whether the endpoint was systolic blood pressure, diastolic blood pressure, or mean arterial blood pressure. CONCLUSIONS: The reliability of systolic blood pressure dipping was somewhat lower than that of diastolic or mean arterial blood pressure dipping. Dipping appears to be a reliable construct. While no one definition of dipping was demonstrably better than another, the most sensible definition of dipping would allow some adjustment for defining 'night' on the basis of each individual's idiosyncratic bed time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Twenty-four-hour ambulatory blood pressure in children with sleep-disordered breathing
Amin, R. S., Carroll, J. L., Jeffries, J. L., Grone, C., Bean, J. A., Chini, B., Bokulic, R., & Daniels, S. R. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200309-1305oc · Cited by 354
Cuspidi, C., Meani, S., Salerno, M., Valerio, C., Fusi, V, Severgnini, B., Lonati, L., Magrini, F., & Zanchetti, A. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001681 · Cited by 79
Reproducibility study of nocturnal blood pressure dipping in patients with high cardiovascular risk
Burgos‐Alonso, N., Ruiz Arzalluz, M. V., Garcia‐Alvarez, A., Fernandez‐Fernandez de Quincoces, D., & Grandes, G. (2021) · The Journal of Clinical Hypertension · doi:10.1111/jch.14222 · Cited by 19
Metadata
- Authors
- Dimsdale, J. E., von Känel, R., Profant, J., Nelesen, R., Ancoli-Israel, S., & Ziegler, M.
- Venue
- Blood Pressure Monitoring
- Published
- 2000-08
- Volume
- 5
- Issue
- 4
- Pages
- 217-221
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2049257688
- Cited by
- 43
- References
- 1
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of nocturnal blood pressure dipping. https://app.cochat.ai/papers/10.1097/00126097-200008000-00004
- The paper
- Dimsdale, J. E., von Känel, R., Profant, J., Nelesen, R., Ancoli-Israel, S., & Ziegler, M. (2000). Reliability of nocturnal blood pressure dipping. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200008000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.