CoChat

Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement

Yarows, Steven A., Patel, Ketul, Brook, Robert · 2001 · Blood Pressure Monitoring
Cited by 29

The DOI matches its Crossref record.

Abstract

BACKGROUND: There have been few reports studying the necessary interval between blood pressure measurements, after the initial rest period. METHODS: Blood pressure was measured in 50 patients using the conventional oscillometric technique (COT) and the rapid oscillometric technique (ROT). RESULTS: The difference between COT and ROT was -1.1 / -0.1 mmHg, which was not significantly different (p = 0.8 / 1.0) and the pulse difference was -0.8 beats per minute (p = 0.8). CONCLUSIONS: It is concluded that a 15-second interval between blood pressure readings is as accurate as a one-minute interval providing that these measurements are started after a 5-minute rest period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200106000-00005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 29

Metadata

Authors
Yarows, S. A., Patel, K., & Brook, R.
Venue
Blood Pressure Monitoring
Published
2001-06
Volume
6
Issue
3
Pages
145-147
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2146294422
Cited by
29
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement. https://app.cochat.ai/papers/10.1097/00126097-200106000-00005
The paper
Yarows, S. A., Patel, K., & Brook, R. (2001). Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200106000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.