Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the morning and an additional two in the evening for at least 3 working days) have been suggested as the upper-normal reference limits. Unfortunately, these values have received limited support because only one study, the Ohasama study, examined the prognostic value of self-measured home blood pressure. For non-invasive 24 h ambulatory blood pressure, there are at least 11 reports of prospective outcome studies from independent centres that have examined the prognostic values of ambulatory blood pressure, but not all have attempted to define reference values. Currently, an average daytime blood pressure of less that 135 mmHg systolic and less than 85 mmHg diastolic is generally considered to be normal, and a level below 130/80 mmHg may be considered optimal. A reduction in blood pressure of less than 10% from day to night identifies subjects with an increased cardiovascular risk. There is some evidence that cardiovascular risk is further increased when night-time blood pressure is higher than daytime blood pressure. An average 24 h pulse pressure of over 53 mmHg identifies subjects with a raised cardiovascular risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Relation Between Nocturnal Decline in Blood Pressure and Mortality The Ohasama Study
Ohkubo, T. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00274-4 · Cited by 491
Cited by
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationHodgkinson, J., Mant, J., Martin, U., Guo, B., Hobbs, F. D. R., Deeks, J. J., Heneghan, C., Roberts, N., & McManus, R. J. (2011) · BMJ · doi:10.1136/bmj.d3621 · Cited by 370
Lovibond, K., Jowett, S., Barton, P., Caulfield, M., Heneghan, C., Hobbs, F. R., Hodgkinson, J., Mant, J., Martin, U., Williams, B., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61184-7 · Cited by 311
Beckett, L., & Godwin, M. (2005) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-5-18 · Cited by 175
“The generally accepted blood pressure target on ABPM is a daytime average pressure of < 135/85 mmHG [2-4]; the target blood pressure when measured in the doctors office is < 140/90 mmHG.”
Metadata
- Authors
- Verdecchia, P.
- Venue
- Blood Pressure Monitoring
- Published
- 2001-12
- Volume
- 6
- Issue
- 6
- Pages
- 323-327
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W1966807518
- Cited by
- 32
- References
- 2
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data. https://app.cochat.ai/papers/10.1097/00126097-200112000-00011
- The paper
- Verdecchia, P. (2001). Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200112000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.