European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement
Open accessAbstract
Patient educationMany patients are anxious to learn more about high blood pressure, and some are anxious to learn how to measure their own blood pressure; illustrated instruction books are helpful in this context and details of this procedure will be considered in more depth in Part IV.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
(1997) · Archives of Internal Medicine · doi:10.1001/archinte.157.21.2413 · Cited by 6,345 · see citing works
Subcommittee, G. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917020-00001 · Cited by 3,895 · see citing works
Staessen, J. A., Fagard, R., Thijs, L., Celis, H., Arabidze, G. G., Birkenhäger, W. H., Bulpitt, C. J., de Leeuw, P. W., Dollery, C. T., Fletcher, A. E., et al. (1997) · The Lancet · doi:10.1016/s0140-6736(97)05381-6 · Cited by 2,989 · see citing works
Self-citationFletcher, G. F., Balady, G. J., Amsterdam, E. A., Chaitman, B., Eckel, R., Fleg, J., Froelicher, V. F., Leon, A. S., Piña, I. L., Rodney, R., et al. (2001) · Circulation · doi:10.1161/hc3901.095960 · Cited by 1,923 · see citing works
Ambulatory blood pressure. An independent predictor of prognosis in essential hypertension.
Verdecchia, P., Porcellati, C., Schillaci, G., Borgioni, C., Ciucci, A., Battistelli, M., Guerrieri, M., Gatteschi, C., Zampi, I., Santucci, A., et al. (1994) · Hypertension · doi:10.1161/01.hyp.24.6.793 · Cited by 1,671 · see citing works
Self-citationHuman blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C. M., Flack, J. M., Frohlich, E. D., Hill, M. D., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,592 · see citing works
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592 · see citing works
Self-citationCircadian blood pressure changes and left ventricular hypertrophy in essential hypertension.
Verdecchia, P., Schillaci, G., Guerrieri, M., Gatteschi, C., Benemio, G., Boldrini, F., & Porcellati, C. (1990) · Circulation · doi:10.1161/01.cir.81.2.528 · Cited by 1,225 · see citing works
Self-citationHow Common Is White Coat Hypertension?
Pickering, T. G. (1988) · JAMA · doi:10.1001/jama.1988.03720020027031 · Cited by 1,183 · see citing works
Self-citationOhkubo, T., Hozawa, A., Yamaguchi, J., Kikuya, M., Ohmori, K., Michimata, M., Matsubara, M., Hashimoto, J., Hoshi, H., Araki, T., et al. (2002) · Journal of Hypertension · doi:10.1097/00004872-200211000-00017 · Cited by 1,053 · see citing works
Self-citationThe association for the advancement of medical instrumentation
(1974) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(74)90035-0 · Cited by 1,031 · see citing works
O'Brien, E. T., Sheridan, J., & O'MALLEY, K. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92867-x · Cited by 1,026 · see citing works
Self-citationNational High Blood Pressure Education Program Working Group on Hypertension Control in Children and Adolescents (1996) · PEDIATRICS · doi:10.1542/peds.98.4.649 · Cited by 999 · see citing works
Blood pressure measuring devices: recommendations of the European Society of Hypertension
O'Brien, E. T., Waeber, B., Parati, G., Staessen, J. A., & Myers, M. G. (2001) · BMJ · doi:10.1136/bmj.322.7285.531 · Cited by 894 · see citing works
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Kato, J., Kikuchi, N., Nishiyama, A., Aihara, A., Sekino, M., Kikuya, M., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00010 · Cited by 782 · see citing works
Self-citationBlood pressure and heart rate variabilities in normotensive and hypertensive human beings.
Mancia, G., Ferrari, A. U., Gregorini, L., Parati, G., Pomidossi, G. A., Bertinieri, G., Grassi, G. M., Rienzo, M. D., Pedotti, A., & Zanchetti, A. (1983) · Circulation Research · doi:10.1161/01.res.53.1.96 · Cited by 770 · see citing works
Self-citationBrien, E. O., Petrie, J. C., Littler, W. A., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D. G., Bland, M., & Atkins, N. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00004 · Cited by 764 · see citing works
Self-citationStroke Prognosis and Abnormal Nocturnal Blood Pressure Falls in Older Hypertensives
Kario, K., Pickering, T. G., Matsuo, T., Hoshide, S., Schwartz, J. E., & Shimada, K. (2001) · Hypertension · doi:10.1161/hy1001.092640 · Cited by 758 · see citing works
Self-citationEFFECTS OF BLOOD-PRESSURE MEASUREMENT BY THE DOCTOR ON PATIENT'S BLOOD PRESSURE AND HEART RATE
Mancia, G. (1983) · The Lancet · doi:10.1016/s0140-6736(83)92244-4 · Cited by 746 · see citing works
Self-citationO'Brien, E. T., Pickering, T. G., Asmar, R. G., Myers, M. G., Parati, G., Staessen, J. A., Mengden, T., Imai, Y., Waeber, B., Palatini, P., et al. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00002 · Cited by 735 · see citing works
Self-citationIncrease in Nocturnal Blood Pressure and Progression to Microalbuminuria in Type 1 Diabetes
Lurbe, E., Redón, J., Kesani, A., Pascual, J. M., Tacons, J., Álvarez, V., & BATLLE, D. C. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013410 · Cited by 723 · see citing works
Ambulatory blood pressure normality: results from the PAMELA study
Mancia, G., Sega, R., Bravi, C., Vito, G. D., Valagussa, F., Cesana, G., & Zanchetti, A. (1995) · Journal of Hypertension · doi:10.1097/00004872-199512000-00003 · Cited by 619 · see citing works
Self-citationPrognostic Value of Ambulatory Blood Pressure
Verdecchia, P. (2000) · Hypertension · doi:10.1161/01.hyp.35.3.844 · Cited by 616 · see citing works
Self-citationRamsay, L., Williams, B., Johnston, G., MacGregor, G. A., Poston, L., Potter, J., Poulter, N. R., Russell, G. I., & for the British Hypertension Society (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000917 · Cited by 576 · see citing works
Alterations of Cardiac Structure in Patients With Isolated Office, Ambulatory, or Home Hypertension
Sega, R., Trocino, G., Lanzarotti, A., Carugo, S., Cesana, G., Schiavina, R., Valagussa, F., Bombelli, M., Giannattasio, C., Zanchetti, A., et al. (2001) · Circulation · doi:10.1161/hc3701.096100 · Cited by 512 · see citing works
Self-citationFriedman, R. H. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00353-3 · Cited by 506 · see citing works
Relation Between Nocturnal Decline in Blood Pressure and Mortality The Ohasama Study
Ohkubo, T. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00274-4 · Cited by 491 · see citing works
Recommendations for the use of home (self) and ambulatory blood pressure monitoring
Pickering, T. G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00341-x · Cited by 473 · see citing works
Self-citationBlood Pressure Response During Treadmill Testing as a Risk Factor for New-Onset Hypertension
Singh, J. P., Larson, M. G., Manolio, T. A., O’Donnell, C. J., Lauer, M. S., Evans, J. C., & Levy, D. A. (1999) · Circulation · doi:10.1161/01.cir.99.14.1831 · Cited by 460 · see citing works
O’Brien, E. (2000) · BMJ · doi:10.1136/bmj.320.7242.1128 · Cited by 451 · see citing works
Self-citationPickering, T. G., Davidson, K. W., Gerin, W., & Schwartz, J. E. (2002) · Hypertension · doi:10.1161/01.hyp.0000038733.08436.98 · Cited by 437 · see citing works
Self-citationPrognostic Value of Ambulatory Blood Pressure Monitoring in Refractory Hypertension
Redón, J., Campos, C., Narciso, M. L., Rodicio, J. L., Pascual, J. M., & Ruilope, L. M. (1998) · Hypertension · doi:10.1161/01.hyp.31.2.712 · Cited by 418 · see citing works
O'Brien, E. T., Mee, F. I., Atkins, N., & Thomas (1996) · PubMed · Cited by 409 · see citing works
Self-citationSchettini, C. A. F., Bianchi, M., Nieto, F., Sandoya, E., & Senra, H. (1999) · HYPERTENSION · doi:10.1161/01.hyp.34.4.818 · Cited by 356 · see citing works
Beevers, G., Lip, G. Y. H., & O'Brien, E. (2001) · BMJ · doi:10.1136/bmj.322.7293.1043 · Cited by 311 · see citing works
Self-citationPrognostic significance of exercise blood pressure and heart rate in middle-aged men.
Filipovský, J., Ducimetière, P., & Safar, M. E. (1992) · Hypertension · doi:10.1161/01.hyp.20.3.333 · Cited by 301 · see citing works
Reliability of reporting self-measured blood pressure values by hypertensive patients.
Mengden, T., Medina, R. M. H., Beltran, B., Álvarez, E., Kraft, K., & Vetter, H. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00241-6 · Cited by 296 · see citing works
Self-citationFagard, R. H., Staessen, J. A., Thijs, L., Gąsowski, J., Bulpitt, C. J., Clement, D. L., de Leeuw, P. W., Dobovišek, J., Jääskivi, M., Leonetti, G., et al. (2000) · Circulation · doi:10.1161/01.cir.102.10.1139 · Cited by 281 · see citing works
Self-citationSever, P., Dahlöf, B., Poulter, N. R., Wedel, H., Beevers, G., Caulfield, M. J., Collins, R., Kjeldsen, S. E., McInnes, G. T., Mehlsen, J., et al. (2001) · Journal of Hypertension · doi:10.1097/00004872-200106000-00020 · Cited by 264 · see citing works
Self-citationStaessen, J. A. (1997) · JAMA · doi:10.1001/jama.278.13.1065 · Cited by 255 · see citing works
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Ito, S., Satoh, H., & Hisamichi, S. (1998) · HYPERTENSION · doi:10.1161/01.hyp.32.2.255 · Cited by 235 · see citing works
Self-citationManolio, T. A., Burke, G. L., Savage, P. J., Sidney, S., Gardin, J. M., & Oberman, A. (1994) · American Journal of Hypertension · doi:10.1093/ajh/7.3.234 · Cited by 232 · see citing works
Gottdiener, J. S., Brown, J., Zoltick, J., & Fletcher, R. D. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-112-3-161 · Cited by 224 · see citing works
Kario, K., Shimada, K., Schwartz, J. E., Matsuo, T., Hoshide, S., & Pickering, T. G. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01325-0 · Cited by 222 · see citing works
Self-citationAmbulatory blood pressure monitoring use in hypertension research and clinical practice.
Mancia, G., Rienzo, M. D., & Parati, G. (1993) · Hypertension · doi:10.1161/01.hyp.21.4.510 · Cited by 218 · see citing works
Self-citation(1991) · Medical Entomology and Zoology · Cited by 215 · see citing works
Guidelines for the use of self-blood pressure monitoring
Asmar, R. G., & Zanchetti, A. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018050-00001 · Cited by 214 · see citing works
Self-citationSelf-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212 · see citing works
Self-citationAppel, L. J., & Stason, W. B. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-11-199306010-00008 · Cited by 207 · see citing works
White coat hypertension and white coat effect similarities and differences*
Verdecchia, P., Schillaci, G., Borgioni, C., Ciucci, A., Zampi, I., Gattobigio, R., Sacchi, N., & Porcellati, C. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00151-e · Cited by 206 · see citing works
Self-citationParati, G., Omboni, S., Rizzoni, D., Agabiti‐Rosei, E., & Manciaa, G. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816110-00016 · Cited by 196 · see citing works
Self-citationTsuji, I. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(96)00407-4 · Cited by 195 · see citing works
Exercise Blood Pressure Predicts Mortality From Myocardial Infarction
Mundal, R., Kjeldsen, S. E., Sandvik, L., Erikssen, G., Thaulow, E., & Erikssen, J. (1996) · Hypertension · doi:10.1161/01.hyp.27.3.324 · Cited by 185 · see citing works
Beevers, G., Lip, G. Y. H., & O'Brien, E. (2001) · BMJ · doi:10.1136/bmj.322.7292.981 · Cited by 183 · see citing works
Self-citationSorof, J. M. (2001) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02180-x · Cited by 179 · see citing works
Inter-arm differences in blood pressure: when are they clinically significant?
Lane, D. A., Beevers, M., Barnes, N., Bourne, J., John, A., Malins, S., & Beevers, D. G. (2002) · Journal of Hypertension · doi:10.1097/00004872-200206000-00019 · Cited by 176 · see citing works
STANDARDISATION OF OBSERVERS IN BLOOD-PRESSURE MEASUREMENT
Rose, G. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91827-1 · Cited by 171 · see citing works
Exaggerated Blood Pressure Response to Dynamic Exercise and Risk of Future Hypertension
Matthews, C. E., Pate, R. R., Jackson, K. L., Ward, D. S., Macera, C. A., Kohl, H. W., & Blair, S. N. (1998) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(97)00223-0 · Cited by 171 · see citing works
Sturrock, N. D. C., George, E., Pound, N., Stevenson, J., Peck, G. M., & Sowter, H. (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00284.x · Cited by 171 · see citing works
Ambulatory blood pressure in pregnancy and fetal growth
Churchill, D. N., Perry, I. J., & Beevers, D. G. (1997) · The Lancet · doi:10.1016/s0140-6736(96)06297-6 · Cited by 169 · see citing works
O'Brien, E. T., Atkins, N., & Staessen, J. A. (1995) · Hypertension · doi:10.1161/01.hyp.26.5.835 · Cited by 158 · see citing works
Self-citationPrognostic Value of 24-Hour Blood Pressure in Pregnancy
Bellomo, G. (1999) · JAMA · doi:10.1001/jama.282.15.1447 · Cited by 156 · see citing works
Difference Between Clinic and Daytime Blood Pressure Is Not a Measure of the White Coat Effect
Parati, G., Ulian, L., Santucciu, C., Omboni, S., & Mancia, G. (1998) · Hypertension · doi:10.1161/01.hyp.31.5.1185 · Cited by 152 · see citing works
Self-citationReference Values for Self-recorded Blood Pressure: A Meta-analysis of Summary Data
Thijs, L., Staessen, J. A., Celis, H., de Gaudemaris, R., Imai, Y., Julius, S., & Fagard, R. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.5.481 · Cited by 143 · see citing works
Self-citationLack of reproducibility in pregnancy of Korotkoff phase IV as measured by mercury sphygmomanometry
Shennan, A. H., Gupta, M., de Swiet, M., Halligan, A., & Taylor, D. J. (1996) · The Lancet · doi:10.1016/s0140-6736(96)90338-4 · Cited by 140 · see citing works
Ohkubo, T., & Imai, Y. (2004) · PubMed · Cited by 140 · see citing works
Self-citationO'Brien, E. T., Beevers, G., & Lip, G. Y. H. (2001) · BMJ · doi:10.1136/bmj.322.7295.1167 · Cited by 139 · see citing works
Self-citationDiagnosis of White Coat Hypertension by Ambulatory Blood Pressure Monitoring
Owens, P., Atkins, N., & O'Brien, E. T. (1999) · Hypertension · doi:10.1161/01.hyp.34.2.267 · Cited by 137 · see citing works
Self-citationRen, J., Hakki, A., Kotler, M. N., & Iskandrian, A. S. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80029-2 · Cited by 137 · see citing works
Twenty-four-hour ambulatory blood pressure measurement in a primigravid population
Halligan, A. W. F., Brien, E. O., O??Malley, K., et al. (1993) · Journal of Hypertension · doi:10.1097/00004872-199308000-00014 · Cited by 135 · see citing works
`Reverse white-coat hypertension’ in older hypertensives
Wing, L. M. H., Brown, M. A., Beilin, L. J., Ryan, P. J., & Reid, C. M. (2002) · Journal of Hypertension · doi:10.1097/00004872-200204000-00020 · Cited by 133 · see citing works
Self-citationSupine and exercise systolic blood pressure predict cardiovascular death in middle-aged men
Kjeldsen, S. E., Mundal, R., Sandvik, L., Erikssen, G., Thaulow, E., & Erikssen, J. (2001) · Journal of Hypertension · doi:10.1097/00004872-200108000-00001 · Cited by 131 · see citing works
Stergiou, G. S., Zourbaki, A. S., Skeva, I. I., & Mountokalakis, T. D. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00038-7 · Cited by 129 · see citing works
Self-citationDelayed systolic blood pressure recovery after graded exercise
McHam, S. A., Marwick, T. H., Pashkow, F. J., & Lauer, M. S. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00269-7 · Cited by 123 · see citing works
How common is white coat hypertension?
Pickering, T. G. (1988) · JAMA · doi:10.1001/jama.259.2.225 · Cited by 115 · see citing works
Self-citationReplacing the mercury sphygmomanometer
O’Brien, E. (2000) · BMJ · doi:10.1136/bmj.320.7238.815 · Cited by 114 · see citing works
Self-citationAmbulatory blood pressure monitoring in clinical trials.
Staessen, J. A., Fagard, R. H., Lijnen, P. J., Thijs, L., Hoof, R. V., & Amery, A. (1991) · PubMed · Cited by 112 · see citing works
Self-citationThe relationship between body weight and blood pressure.
Staessen, J. A., Fagard, R. H., & Amery, A. (1988) · PubMed · Cited by 110 · see citing works
Self-citationCharacteristics of blood pressure measured at home in the morning and in the evening
Imai, Y., Nishiyama, A., Sekino, M., Aihara, A., Kikuya, M., Ohkubo, T., Matsubara, M., Hozawa, A., Tsuji, I., Ito, S., et al. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917070-00004 · Cited by 110 · see citing works
Self-citationHow accurate are sphygmomanometers?
Mion, D., & Pierin, A. (1998) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000589 · Cited by 110 · see citing works
Staessen, J. A., O'Brien, E. T., Atkins, N., et al. (1993) · PubMed · Cited by 110 · see citing works
Self-citationIndependent predictors of isolated clinic (`white-coat') hypertension
Verdecchia, P., Palatini, P., Schillaci, G., Mormino, P., Porcellati, C., & Pessina, A. C. (2001) · Journal of Hypertension · doi:10.1097/00004872-200106000-00004 · Cited by 108 · see citing works
Self-citationClinical value of ambulatory blood pressure monitoring
Mallion, J.-M., Baguet, J.-P., Siche, J. P., Tremel, F., & Gaudemaris, R. D. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917050-00001 · Cited by 107 · see citing works
Self-citationDoes self-measurement of blood pressure improve patient compliance in hypertension?
Edmonds, D., Foerster, E. H., Groth, H., Greminger, P., Siegenthaler, W. E., & Vetter, W. (1985) · PubMed · Cited by 104 · see citing works
Beevers, D. G., Lip, G. Y. H., & O’Brien, E. (1987) · Medical Entomology and Zoology · Cited by 103 · see citing works
Self-citationImai, Y., Ohkubo, T., Hozawa, A., Tsuji, I., Matsubara, M., Araki, T., Chonan, K., Kikuya, M., Satoh, H., Hisamichi, S., et al. (2001) · Journal of Hypertension · doi:10.1097/00004872-200102000-00003 · Cited by 102 · see citing works
Self-citationSeasonal Variation in Blood Pressure in Normotensive Women Studied by Home Measurements
Imai, Y., Munakata, M., Tsuji, I., Ohkubo, T., Satoh, H., Yoshino, H., Watanabe, N., Nishiyama, A., Onodera, N., Kato, J., et al. (1996) · Clinical Science · doi:10.1042/cs0900055 · Cited by 100 · see citing works
Self-citationPenny, J. A., Halligan, A., Shennan, A. H., Lambert, P. C., Jones, D. R., de Swiet, M., & Taylor, D. J. (1998) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(98)70432-6 · Cited by 100 · see citing works
Verdecchia, P., Schillaci, G., Borgioni, C., Ciucci, A., & Porcellati, C. (1996) · The Lancet · doi:10.1016/s0140-6736(04)70084-7 · Cited by 98 · see citing works
Self-citationElectrocardiogram in Evaluation of Resistance to Antihypertensive Therapy
Ibrahim, M. M. (1977) · Archives of Internal Medicine · doi:10.1001/archinte.1977.03630210011006 · Cited by 98 · see citing works
Properly defining white coat hypertension
Verdecchia, P. (2002) · European Heart Journal · doi:10.1053/euhj.2001.2657 · Cited by 96 · see citing works
Self-citationHiggins, J. R., Walshe, J. J., Halligan, A. W. F., et al. (1997) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1997.tb11468.x · Cited by 95 · see citing works
Arterial distensibility and ambulatory blood pressure monitoring in essential hypertension
Asmar, R. G., Brunel, P., Pannier, B., Lacolley, P. J., & Safar, M. E. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)90127-0 · Cited by 93 · see citing works
Self-citationSphygmomanometers in hospital and family practice: problems and recommendations.
Burke, M. J., Towers, H. M., O'MALLEY, K., Fitzgerald, D. J., & O'Brien, E. T. (1982) · BMJ · doi:10.1136/bmj.285.6340.469 · Cited by 91 · see citing works
Self-citationPseudohypertension in the Elderly
Spence, J. D., Sibbald, W. J., & Cape, R. D. T. (1978) · Clinical Science · doi:10.1042/cs055399s · Cited by 90 · see citing works
White Coat Phenomenon in Patients Receiving Antihypertensive Therapy
Myers, M. G., & Reeves, R. A. (1991) · American Journal of Hypertension · doi:10.1093/ajh/4.10.844 · Cited by 86 · see citing works
Self-citationReview: a century of confusion; which bladder for accurate blood pressure measurement?
O'Brien, E. T. (1996) · PubMed · Cited by 83 · see citing works
Self-citationStaessen, J. A., Broughton, P. M. G., FLETCHER, A. E., et al. (1991) · Journal of Hypertension · doi:10.1097/00004872-199111000-00009 · Cited by 82 · see citing works
Self-citationWhite coat effect in treated hypertensive patients: sex differences.
Myers, M. G., & Reeves, R. A. (1995) · PubMed · Cited by 78 · see citing works
Self-citationThe history of blood pressure measurement.
O'Brien, E. T., & Fitzgerald, D. (1994) · PubMed · Cited by 77 · see citing works
Self-citationNormotension and Hypertension as Defined by 24-hour Ambulatory Blood Pressure Monitoring
O'Brien, E. T., & Staessen, J. A. (1995) · Blood Pressure · doi:10.3109/08037059509077607 · Cited by 77 · see citing works
Self-citationCanadian hypertension society guidelines for ambulatory blood pressure monitoring
Myers, M. G. (1999) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00199-5 · Cited by 76 · see citing works
Self-citationWhat will replace the mercury sphygmomanometer?
Pickering, T. G. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200302000-00005 · Cited by 76 · see citing works
Self-citationConroy, R. M., O'Brien, E. T., O'MALLEY, K., et al. (1993) · BMJ · doi:10.1136/bmj.306.6888.1319 · Cited by 75 · see citing works
Self-citationBlood pressure measurement : recommendations of the British Hypertension Society
O’Brien, E., Petrie, J. C., Littler, W. A., et al. (1997) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 74 · see citing works
Self-citationOwens, P., & O'Brien, E. T. (1999) · Heart · doi:10.1136/hrt.82.4.477 · Cited by 73 · see citing works
Self-citationO'Brien, E., Beevers, G., & Lip, G. Y. H. (2001) · BMJ · doi:10.1136/bmj.322.7294.1110 · Cited by 70 · see citing works
Self-citationModern approaches to blood pressure measurement
Staessen, J. A., O'Brien, E. T., Thijs, L., & Fagard, R. H. (2000) · Occupational and Environmental Medicine · doi:10.1136/oem.57.8.510 · Cited by 68 · see citing works
Self-citationPrognosis in Essential Hypertension
PALMER, R. S., Loofbourow, D. G., & Doering, C. R. (1948) · New England Journal of Medicine · doi:10.1056/nejm194812232392602 · Cited by 65 · see citing works
Parati, G., Ulian, L., Sampieri, L., Palatini, P., Villani, A., Vanasia, A., & Mancia, G. (2000) · Hypertension · doi:10.1161/01.hyp.35.2.614 · Cited by 64 · see citing works
Self-citationOwens, P., Lyons, S., Rodriguez, S., & O’Brien, E. (1998) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000721 · Cited by 64 · see citing works
Self-citationStewart, M. J., Gough, K., & Padfield, P. L. (1995) · Journal of Hypertension · doi:10.1097/00004872-199503000-00004 · Cited by 63 · see citing works
Self-citationCasadei, R., Parati, G., Pomidossi, G. A., et al. (1988) · PubMed · Cited by 63 · see citing works
Self-citationMengden, T., Chamontin, B., Chau, N. P., Gámiz, J. L. P., & Chanudet, X. (2000) · PubMed · Cited by 60 · see citing works
Self-citationNeus, H., dderz, W. G., Otten, H., ddel, H. R., & Eiff, A. W. V. (1985) · Journal of Hypertension · doi:10.1097/00004872-198502000-00006 · Cited by 59 · see citing works
Self-measurement of blood pressure at home to evaluate drug effects by the trough
M??nard, J., Châtellier, G., Day, M., & Vaur, L. (1994) · Journal of Hypertension · doi:10.1097/00004872-199412001-00005 · Cited by 58 · see citing works
Palatini, P., Dorigatti, F., Roman, E., Giovinazzo, P., Piccolo, D., Venuto, G. D., Mattarei, M., Cozzutti, E., Gregori, S., Mormino, P., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00011 · Cited by 57 · see citing works
Self-citationSelf blood pressure monitoring at home by wrist devices: a reliable approach?
Parati, G., Asmar, R., & Stergiou, G. S. (2002) · Journal of Hypertension · doi:10.1097/00004872-200204000-00005 · Cited by 53 · see citing works
Self-citationde SWIET, M., Dillon, M. J., Littler, W. A., et al. (1989) · BMJ · doi:10.1136/bmj.299.6697.497 · Cited by 53 · see citing works
Optimal definition of daytime and night-time blood pressure.
Fagard, R., Staessen, J. A., & Thijs, L. (1997) · PubMed · Cited by 51 · see citing works
Self-citationBlood pressure variability, cardiovascular risk and antihypertensive treatment
Parati, G., Ulian, L., Santucciu, C., et al. (1995) · Journal of Hypertension · doi:10.1097/00004872-199512002-00005 · Cited by 51 · see citing works
Self-citationAsmar, R. G., Girerd, X. J., Brahimi, M., et al. (1992) · Journal of Hypertension · doi:10.1097/00004872-199202000-00012 · Cited by 51 · see citing works
Self-citationBlood pressure during siesta: effect on 24-h ambulatory blood pressure profiles analysis
Stergiou, G. S., Malakos, J., Zourbaki, A. S., et al. (1997) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000383 · Cited by 50 · see citing works
Self-citationMancia, G., Sega, R., Grassi, G., Cesana, G., & Zanchetti, A. (2001) · Journal of Hypertension · doi:10.1097/00004872-200106000-00001 · Cited by 49 · see citing works
Self-citationAccuracy of indirect blood pressure measurement in the elderly.
O'Callaghan, W. G., Fitzgerald, D. J., O'MALLEY, K., et al. (1983) · BMJ · doi:10.1136/bmj.286.6377.1545-a · Cited by 49 · see citing works
Winnicki, M., Canali, C., Mormino, P., & Palatini, P. (1997) · PubMed · Cited by 48 · see citing works
Self-citationA new approach to assessing antihypertensive therapy
Asmar, R. G., & Lacourcière, Y. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018110-00022 · Cited by 47 · see citing works
Self-citationWill mercury manometers soon be obsolete?
O'Brien, E. T. (1995) · PubMed · Cited by 46 · see citing works
Self-citationGrim, C. M., & Grim, C. E. (1995) · PubMed · Cited by 45 · see citing works
Ambulatory blood pressure monitoring in the management of hypertension
O'Brien, E. T. (2003) · Heart · doi:10.1136/heart.89.5.571 · Cited by 45 · see citing works
Self-citationDiagnosing Gestational Hypertension and Preeclampsia With the 24-Hour Mean of Blood Pressure
Hermida, R. C., & Ayala, D. E. (1997) · Hypertension · doi:10.1161/01.hyp.30.6.1531 · Cited by 44 · see citing works
Pickering, T. G., & O’Brien, E. (1991) · PubMed · Cited by 43 · see citing works
Self-citationVerdecchia, P., Schillaci, G., Porcellati, C., & Silvestrini, O. R. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917010-00023 · Cited by 42 · see citing works
Self-citationTraining and assessment of observers for blood pressure measurement in hypertension research.
O'Brien, E. T., Mee, F. D., Tan, K. S., Atkins, N., & O'MALLEY, K. (1991) · PubMed · Cited by 40 · see citing works
Self-citationCunha, R. S. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(94)00249-b · Cited by 38 · see citing works
Ambulatory blood pressure monitoring: a critical review of the current methods to handle outliers
Berardi, L., Chau, N. P., Chanudet, X., et al. (1992) · Journal of Hypertension · doi:10.1097/00004872-199210000-00019 · Cited by 38 · see citing works
Palatini, P. (2002) · Journal of Hypertension · doi:10.1097/00004872-200210000-00003 · Cited by 37 · see citing works
Self-citationConsensus Conference on Self-blood pressure measurement. Clinical applications and diagnosis.
Herpin, D., Pickering, T. G., Stergiou, G. S., et al. (2000) · PubMed · Cited by 35 · see citing works
Self-citationAve atque vale: the centenary of clinical sphygmomanometry
O'Brien, E. T. (1996) · The Lancet · doi:10.1016/s0140-6736(96)10033-7 · Cited by 35 · see citing works
Self-citationLurbe, E. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00058-1 · Cited by 35 · see citing works
Brown, W., Kennedy, S., Inglis, G. C., Murray, L., & Lever, A. F. (1997) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000405 · Cited by 35 · see citing works
Proceedings from a Consensus Conference on Self-Blood Pressure Measurement. Devices and validation.
O’Brien, E., Gaudemaris, R. D., Bobrie, G., et al. (2000) · PubMed · Cited by 34 · see citing works
Self-citationThe unsupported arm: a cause of falsely raised blood pressure readings.
Silverberg, D., Shemesh, E., & Iaina, A. (1977) · British medical journal · doi:10.1136/bmj.2.6098.1331 · Cited by 34 · see citing works
Ambulatory blood pressure in the hypertensive population
Owens, P., Lyons, S., & O'Brien, E. T. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816120-00005 · Cited by 34 · see citing works
Self-citationSelf-measurement of blood pressure in clinical trials and therapeutic applications.
Denolle, T., Waeber, B., Kjeldsen, S. E., et al. (2000) · PubMed · Cited by 34 · see citing works
24-Hour blood pressure monitoring
Casadei, R., Parati, G., Pomidossi, G. A., et al. (1988) · Journal of Hypertension · doi:10.1097/00004872-198810000-00006 · Cited by 34 · see citing works
Self-citationInaccuracy of London School of Hygiene sphygmomanometer.
Fitzgerald, D. J., O’Malley, K., & O'Brien, E. T. (1982) · BMJ · doi:10.1136/bmj.284.6308.18 · Cited by 33 · see citing works
Self-citationVerdecchia, P. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200112000-00011 · Cited by 32 · see citing works
Self-citationAmbulatory blood pressure monitoring in the evaluation of antihypertensive drugs
Parati, G., Ravogli, A., Mutti, E., et al. (1994) · Journal of Hypertension · doi:10.1097/00004872-199412001-00003 · Cited by 30 · see citing works
Self-citationBrueren, M., Schouten, H. J. A., de Leeuw, P. W., van Montfrans, G. A., & van Ree, J. W. (1998) · Europe PMC (PubMed Central) · Cited by 29 · see citing works
Prognostic significance of self-measurements of blood pressure.
Imai, Y., Poncelet, P., DEBUYZERE, M., et al. (2000) · PubMed · Cited by 28 · see citing works
Self-citationStaessen, J. A., & Thijs, L. (2000) · PubMed · Cited by 28 · see citing works
Self-citationMeasuring blood pressure in normal and hypertensive pregnancy
Shennan, A. H., & Halligan, A. (1999) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1053/beog.1999.0003 · Cited by 28 · see citing works
Verapmil and Nitrendipine in Hypertensive Patients Resistant to Betablocker
Edmonds, D., Foerster, E. C., Groth, H., et al. (1985) · Journal of Hypertension · doi:10.1097/00004872-198508000-00033 · Cited by 27 · see citing works
Automated blood pressure measurement as a predictor of proteinuric pre‐eclampsia
Halligan, A. W. F., Shennan, A., Lambert, P. C., et al. (1997) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1997.tb11532.x · Cited by 26 · see citing works
Uen, S., Weisser, B., Wieneke, P., Vetter, H., & Mengden, T. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02979-5 · Cited by 25 · see citing works
Self-citationWill the millimetre of mercury be replaced by the kilopascal?
O'Brien, E. T. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816030-00001 · Cited by 24 · see citing works
Self-citationAmbulatory blood pressure monitoring in clinical practice
Parati, G., & Mancia, G. (2002) · Journal of Hypertension · doi:10.1097/00004872-200210000-00004 · Cited by 24 · see citing works
Self-citationHypotension: a forgotten illness?.
Owens, P., & O’Brien, E. (1997) · PubMed · Cited by 24 · see citing works
Self-citationState of the market in 2001 for blood pressure measuring devices
O'Brien, E. T. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200108000-00001 · Cited by 23 · see citing works
Self-citationVanhanen, H. T., Thijs, L., ger, W. B., Tilvis, R. S., Sarti, C., Tuomilehto, J., Bulpitt, C. J., Fagard, R. H., Staessen, J. A., & The Syst-Eur Investigators (1996) · Journal of Hypertension · doi:10.1097/00004872-199608000-00003 · Cited by 22 · see citing works
Self-citationBlood pressure should be measured in both arms on the first consultation
Gosse, P. (2002) · Journal of Hypertension · doi:10.1097/00004872-200206000-00004 · Cited by 21 · see citing works
Moser, M. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00106-x · Cited by 19 · see citing works
Strachan, M. W. J., Gough, K., McKnight, J. A., & Padfield, P. L. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00771.x · Cited by 18 · see citing works
Self-citationDirect and surrogate measures of the white-coat effect
Parati, G., & Redón, J. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018040-00004 · Cited by 18 · see citing works
Self-citationTask Force II: Ambulatory blood pressure monitoring in population studies
Mancia, G., O'Brien, E. T., Imai, Y., et al. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199912000-00003 · Cited by 17 · see citing works
Self-citationWhat are the normal levels for ambulatory blood pressure measurement?
O'Brien, E. T., Owens, P., Staessen, J. A., et al. (1998) · PubMed · Cited by 15 · see citing works
Self-citationHome measurement of blood pressure: training of relatives.
Ms, L., O’Boyle, C. A., Quinn, C., et al. (1981) · PubMed · Cited by 15 · see citing works
Consequences of banning mercury and the cuff controversy
O'Brien, E. T. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200002000-00007 · Cited by 14 · see citing works
Self-citationTreatment of the Infertile Marriage
Rc, B. (1948) · BMJ · doi:10.1136/bmj.2.4584.851 · Cited by 13 · see citing works
Ambulatory blood pressure in clinical trials
Staessen, J. A. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200002000-00009 · Cited by 12 · see citing works
Self-citationK5 Rather Than K4 for Diastolic Blood Pressure Measurement in Pregnancy
de SWIET, M. (1999) · Hypertension in Pregnancy · doi:10.3109/10641959909016191 · Cited by 12 · see citing works
O'Brien, E. T., & O'MALLEY, K. (1979) · BMJ · doi:10.1136/bmj.2.6194.851 · Cited by 12 · see citing works
Self-citationGuidelines on the clinical utility of ambulatory blood pressure.
White, W. (1998) · PubMed · Cited by 9 · see citing works
Asmar, R. (2000) · PubMed · Cited by 8 · see citing works
Self-citationZanchetti, A. (1991) · Journal of Hypertension · doi:10.1097/00004872-199112000-00001 · Cited by 7 · see citing works
O'Brien, E. T., & O'MALLEY, K. (1994) · Developments in cardiovascular medicine · doi:10.1007/978-94-017-1820-2_2 · Cited by 3 · see citing works
Self-citationMancia, G., O'Brien, E. T., Imai, Y., et al. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199905000-00003 · Cited by 2 · see citing works
Self-citationArterielle Hypertonie - Der konkrete Fall
Weisser, B., Düsing, R., & Mengden, T. (2001) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/s-2001-18130 · Cited by 1 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 20
- [1]1. Beevers G, Lip GHY, O'Brien E. ABC of references hypertension. Part I. Sphygmomanometry: factors common to all techniques. BMJ 2001; 322:981-985.
- [21]21. Parati G, Ulian G, Sampieri L, Palatini P, Villani A, Vanasia A, et al., on behalf of the Study on Ambulatory Monitoring of Blood Pressure and Lisinopril Evaluation (SAMPLE) Study Group. Attenuation of the 'white coat effect' by antihypertensive treatment and its relationship to regres- sion of target organ damage. Hypertension 2000; 35:614-620.
- [28]28. Pickering T. Ambulatory monitoring and blood pressure variability, Part I. London: Science Press; 1990. p. 2.8.
- [56]56. Keary L, Atkins N, Molloy E, Mee F, O'Brien E. Terminal digit preference and heaping in blood pressure measurement. J Hum Hypertens 1998; 12:787-788.
- [66]66. Burke MJ, Towers HM, O'Malley K, Fitzgerald D, O'Brien E. Sphygmo- manometers in hospitals and family practice: problems and recommen- dations. BMJ 1982; 285:469-471.
- [74]74. O'Brien E, Beevers G, Lip GHY. ABC of hypertension. Part III. Automated sphygmomanometry: ambulatory blood pressure measure- ment. BMJ 2001; 322:1110-1114.
- [99]99. O'Brien E. Ambulatory blood pressure monitoring in primary care: a comment. Br J Cardiol 2001; 8:531-535. 103
- [101]101. Waeber B, Schubiger JL, Wohler D, Nawrath T, Richter A, Brandt A, et al. What are the costs or savings ambulatory blood pressure monitoring can produce in the treatment of hypertension? In: Proceed- ings of the XXXIVth International Conference on Applied Econometrics; 1992; Munich. pp. 131-137. 105
- [103]103. Parati G, Rizzoni D, Omboni S, Bernardi L, Mormino P, Di Rienzo M. The analysis of blood pressure and heart rate variability: methodological aspects and interpretation of results. High Blood Press 1995; 4: 186-203. 107
- [107]107. Winnicki M, Canali C, Mormino P, Palatini P. Ambulatory blood pressure monitoring editing criteria. Is standardization needed? Am J Hypertens 1997; 10:419-427. 111
- [113]113. Mancia G, Sega R, Grassi G, Cesana G, Zanchetti A. Defining ambulatory and home blood pressure variability. Further considerations from PAMELA study. J Hyperens 2001; 19:995-999. 117
- [132]132. Staessen JA, Fagard R, Thijs L, Celis H, Arabidze GG, Birkenhager WH, et al. Randomised double-blind comparison of placebo and active treatment for older patients with isolated systolic hypertension. Lancet 1997; 350:757-764. 137
- [134]134. Verdecchia P, Schillaci G, Borgioni C, Ciucci A, Gattobigio R, Porcellati C. Nocturnal pressure is the true pressure. Blood Press Monit 1996; 1: S81-S85. 139
- [138]138. Halligan A, O'Brien E, O'Malley K, Mee F, Atkins N, Conroy R, et al. Twenty-four hour ABPM in a primigravid population. J Hypertens 1993; 11:869-873. 143
- [140]140. Higgins JR, Walshe JJ, Halligan A, O'Brien E, Conroy R, Darling MR. Can 24 hour ABPM predict the development of hypertension in primigravidae? Br J Obstet Gynaecol 1997; 104:356-362. 145
- [143]143. Churchill D, Perry IJ, Beevers DG. ABPM in pregnancy and fetal growth. Lancet 1997; 349:7-10. 148
- [148]148. Mallion J-M, Baguet J-P, Siche ´J-P, Tremel F, De Gaudemaris R. Clinical value of ABPM monitoring. J Hypertens 1999; 17:585-595. 153
- [149]149. White W. Guidelines on the clinical utility of ABPM. Blood Press Monit 1998; 3:181-184. 154
- [178]178. Sega R, Trocino G, Lanzarotti A, Carugo S, Cesana G, Schiavina R, et al. Alterations in cardiac structure in patients with isolated office, ambulatory or home hypertension. Data from the PAMELA study. Circulation 2001; 104:1385-1392. 185
- [185]185. Verdecchia P, Bentivoglio M, Providenza M, Savino K, Corea L. Reliability of home self-recorded arterial pressure in essential hyper- tension in relation to the stage of the disease. In: Germano G, (editor): Blood pressure recording in the clinical management of hypertension. Rome: Ediziono Pozzi; 1985. pp. 40-42.
Cited by
Sorted by citations
European Guidelines on cardiovascular disease prevention in clinical practice (version 2012)
Authors/Task Force Members:, Perk, J., De Backer, G., Gohlke, H., Graham, I., Reiner, Ž., Verschuren, M., Albus, C., Benlian, P., Boysen, G., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs092 · Cited by 8,490 · see citing works
Self-citationPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985 · see citing works
Self-citationPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051 · see citing works
Self-citationWillum Hansen, T., Staessen, J. A., Torp-Pedersen, C., Rasmussen, S., Thijs, L., Ibsen, H., & Jeppesen, J. (2006) · Circulation · doi:10.1161/circulationaha.105.579342 · Cited by 1,515 · see citing works
Self-citationEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419 · see citing works
Self-citationDolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227 · see citing works
Self-citationPelliccia, A. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi325 · Cited by 983 · see citing works
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837 · see citing works
Self-citationde la Sierra, A., Segura, J., Banegas, J. R., Gorostidi, M., de la Cruz, J. J., Armario, P., Oliveras, A., & Ruilope, L. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.168948 · Cited by 809 · see citing works
RETRACTED: Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality
Banegas, J. R., Ruilope, L. M., de la Sierra, A., Vinyoles, E., Gorostidi, M., de la Cruz, J. J., Ruiz-Hurtado, G., Segura, J., Rodríguez-Artalejo, F., & Williams, B. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1712231 · Cited by 490 · see citing works
RetractedPrevalence and Factors Associated With Circadian Blood Pressure Patterns in Hypertensive Patients
de la Sierra, A., Redon, J., Banegas, J. R., Segura, J., Parati, G., Gorostidi, M., de la Cruz, J. J., Sobrino, J., Llisterri, J. L., Alonso, J., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.124008 · Cited by 379 · see citing works
Self-citationA Randomized Trial of Dietary Sodium Restriction in CKD
McMahon, E. J., Bauer, J. D., Hawley, C. M., Isbel, N. M., Stowasser, M., Johnson, D. W., & Campbell, K. L. (2013) · Journal of the American Society of Nephrology · doi:10.1681/asn.2013030285 · Cited by 308 · see citing works
Stergiou, G. S., Asayama, K., Thijs, L., Kollias, A., Niiranen, T. J., Hozawa, A., Boggia, J., Johansson, J. K., Ohkubo, T., Tsuji, I., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02741 · Cited by 304 · see citing works
Self-citationStaessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288 · see citing works
Self-citationOhkubo, T., Asayama, K., Kikuya, M., Metoki, H., Hoshi, H., Hashimoto, J., Totsune, K., Satoh, H., & Imai, Y. (2004) · Journal of Hypertension · doi:10.1097/00004872-200406000-00009 · Cited by 287 · see citing works
Self-citationStaplin, N., de la Sierra, A., Ruilope, L. M., Emberson, J. R., Vinyoles, E., Gorostidi, M., Ruiz-Hurtado, G., Segura, J., Baigent, C., & Williams, B. (2023) · The Lancet · doi:10.1016/s0140-6736(23)00733-x · Cited by 290 · see citing works
Masked hypertension: A systematic review
Bobrie, G., Clerson, P., Ménard, J., Postel-Vinay, N., Chatellier, G., & Plouin, P.-F. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282fbcedf · Cited by 279 · see citing works
Roush, G. C., Fagard, R. H., Salles, G. F., Pierdomenico, S. D., Reboldi, G., Verdecchia, P., Eguchi, K., Kario, K., Hoshide, S., Polonia, J., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000355 · Cited by 272 · see citing works
Self-citationPeter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261 · see citing works
Bliziotis, I. A., Destounis, A., & Stergiou, G. S. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283531eaf · Cited by 261 · see citing works
Self-citationPépin, J.-L., Tamisier, R., Barone-Rochette, G., Launois, S. H., Lévy, P., & Baguet, J.-P. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1803oc · Cited by 232 · see citing works
Vistisen, D., Andersen, G. S., Hansen, C. S., Hulman, A., Henriksen, J. E., Bech-Nielsen, H., & Jørgensen, M. E. (2016) · Circulation · doi:10.1161/circulationaha.115.018844 · Cited by 229 · see citing works
Pruijm, M., Milani, B., Pivin, E., Podhajska, A., Vogt, B., Stuber, M., & Burnier, M. (2018) · Kidney International · doi:10.1016/j.kint.2017.10.020 · Cited by 200 · see citing works
Drawz, P. E., Alper, A. B., Anderson, A. H., Brecklin, C. S., Charleston, J., Chen, J., Deo, R., Fischer, M. J., He, J., Hsu, C.-Y., et al. (2016) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.08530815 · Cited by 199 · see citing works
Palatini, P., Reboldi, G., Beilin, L. J., Casiglia, E., Eguchi, K., Imai, Y., Kario, K., Ohkubo, T., Pierdomenico, S. D., Schwartz, J. E., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03694 · Cited by 193 · see citing works
Self-citationParati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178 · see citing works
Self-citationMcDaid, C., Durée, K. H., Griffin, S. C., Weatherly, H. L. A., Stradling, J. R., Davies, R. J. O., Sculpher, M. J., & Westwood, M. E. (2009) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2009.02.004 · Cited by 180 · see citing works
Drawz, P. E., Pajewski, N. M., Bates, J. T., Bello, N. A., Cushman, W. C., Dwyer, J. P., Fine, L. J., Goff, D. C., Haley, W. E., Krousel-Wood, M., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08076 · Cited by 170 · see citing works
Zhang, Y., Agnoletti, D., Safar, M. E., & Blacher, J. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.174383 · Cited by 162 · see citing works
STERGIOU, G., SALGAMI, E., TZAMOURANIS, D., & ROUSSIAS, L. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.01.003 · Cited by 157 · see citing works
Self-citationNon-dipping pattern of hypertension and obstructive sleep apnea syndrome
Wolf, J., Hering, D., & Narkiewicz, K. (2010) · Hypertension Research · doi:10.1038/hr.2010.153 · Cited by 156 · see citing works
Correlates of Systolic Hypertension in Patients With Chronic Kidney Disease
Agarwal, R., & Andersen, M. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000178102.85718.66 · Cited by 133 · see citing works
Home Blood Pressure Monitoring in CKD
Andersen, M. J., Khawandi, W., & Agarwal, R. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.02.015 · Cited by 123 · see citing works
Automated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis
Stergiou, G. S., Kollias, A., Destounis, A., & Tzamouranis, D. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835850d7 · Cited by 120 · see citing works
Self-citationHome blood pressure normalcy in children and adolescents: the Arsakeion School study
Stergiou, G. S., Yiannes, N. G., Rarra, V. C., & Panagiotakos, D. B. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e328122d3fc · Cited by 119 · see citing works
Self-citationHoshide, S., Kario, K., de la Sierra, A., Bilo, G., Schillaci, G., Banegas, J. R., Gorostidi, M., Segura, J., Lombardi, C., Omboni, S., et al. (2015) · Hypertension · doi:10.1161/hypertensionaha.115.05958 · Cited by 117 · see citing works
Self-citationHermida, R. C., Ayala, D. E., Calvo, C., & López, J. E. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.08.071 · Cited by 111 · see citing works
Factors influencing white-coat effect
Manios, E. D., Koroboki, E. A., Tsivgoulis, G. K., Spengos, K. M., Spiliopoulou, I. K., Brodie, F. G., Vemmos, K. N., & Zakopoulos, N. A. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2007.43 · Cited by 100 · see citing works
Agarwal, R., Sinha, A. D., Pappas, M. K., & Ammous, F. (2014) · American Journal of Nephrology · doi:10.1159/000358603 · Cited by 99 · see citing works
Orthostatic hypotension in very old individuals living in nursing homes: the PARTAGE study
Valbusa, F., Labat, C., Salvi, P., Vivian, M. E., Hanon, O., & Benetos, A. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834d3d73 · Cited by 91 · see citing works
Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure
Sharman, J. E., Tan, I., Stergiou, G. S., Lombardi, C., Saladini, F., Butlin, M., Padwal, R., Asayama, K., Avolio, A., Brady, T. M., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00693-x · Cited by 84 · see citing works
Self-citationStergiou, G. S., Lourida, P., Tzamouranis, D., & Baibas, N. M. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.20 · Cited by 74 · see citing works
Self-citationAccuracy of Automated Blood Pressure Measurement in Children: Evidence, Issues, and Perspectives
Stergiou, G. S., Boubouchairopoulou, N., & Kollias, A. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08553 · Cited by 72 · see citing works
Self-citationDevelopment and validation of the experiential avoidance in caregiving questionnaire (EACQ)
Losada, A., Márquez-González, M., Romero-Moreno, R., & López, J. (2014) · Aging & Mental Health · doi:10.1080/13607863.2014.896868 · Cited by 64 · see citing works
Bönner, G., Bakris, G. L., Sica, D., Weber, M. A., White, W. B., Perez, A., Cao, C., Handley, A., & Kupfer, S. (2013) · Journal of Human Hypertension · doi:10.1038/jhh.2013.6 · Cited by 61 · see citing works
Asferg, C. L., Nielsen, S. J., Andersen, U. B., Linneberg, A., Møller, D. V., Hedley, P. L., Christiansen, M., Goetze, J. P., Esler, M., & Jeppesen, J. L. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00791 · Cited by 58 · see citing works
Stergiou, G. S., Palatini, P., Asmar, R., Bilo, G., de la Sierra, A., Head, G., Kario, K., Mihailidou, A., Wang, J., Mancia, G., et al. (2018) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000301 · Cited by 57 · see citing works
Self-citationParati, G., Omboni, S., Compare, A., Grossi, E., Callus, E., Venco, A., Destro, M., Villa, G., Palatini, P., Rosei, E. A., et al. (2013) · Trials · doi:10.1186/1745-6215-14-22 · Cited by 49 · see citing works
Self-citationPrevalence and correlates of coronary heart disease: first population-based study in Lebanon
Zeidan, Farah, R., Chahine, M. N., Asmar, R., Hosseini, H., Salameh, P., & Pathak, A. (2016) · Vascular Health and Risk Management · doi:10.2147/vhrm.s97252 · Cited by 47 · see citing works
Self-citationTaylor, K. S., Heneghan, C. J., Stevens, R. J., Adams, E. C., Nunan, D., & Ward, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0126375 · Cited by 48 · see citing works
Role of ambulatory and home blood pressure recording in clinical practice.
Ghuman, N., Campbell, P., & White, W. B. (2009) · Current Cardiology Reports · doi:10.1007/s11886-009-0060-6 · Cited by 44 · see citing works
Kaminski, G., Michalkiewicz, D., Makowski, K., Podgajny, Z., Szalus, N., Ruchala, M., Szczepanek, E., & Gielerak, G. (2011) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2010.03957.x · Cited by 45 · see citing works
Ferland, A., Poirier, P., & Sériès, F. (2009) · European Respiratory Journal · doi:10.1183/09031936.00167308 · Cited by 43 · see citing works
Severin, R., Sabbahi, A., Albarrati, A., Phillips, S. A., & Arena, S. (2020) · Physical Therapy · doi:10.1093/ptj/pzaa034 · Cited by 43 · see citing works
Bilo, G., Sala, O., Perego, C., Faini, A., Gao, L., Głuszewska, A., Ochoa, J. E., Pellegrini, D., Lonati, L. M., & Parati, G. (2017) · Hypertension Research · doi:10.1038/hr.2016.184 · Cited by 43 · see citing works
Self-citationBOBRIE, G., DELONCA, J., MOULIN, C., GIACOMINO, A., POSTELVINAY, N., & ASMAR, R. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.06.009 · Cited by 42 · see citing works
Self-citationNIIRANEN, T., KANTOLA, I., VESALAINEN, R., JOHANSSON, J., & RUUSKA, M. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.10.017 · Cited by 42 · see citing works
Fuchs, S. C., Ferreira-da-silva, A. L., Moreira, L. B., Neyeloff, J. L., Fuchs, F. C., Gus, M., Wiehe, M., & Fuchs, F. D. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834e5a4f · Cited by 36 · see citing works
Sheng, C.-S., Li, Y., Huang, Q.-F., Kang, Y.-Y., Li, F.-K., & Wang, J.-G. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06666 · Cited by 37 · see citing works
Diagnosis and management of resistant hypertension: state of the art
Wei, F.-F., Zhang, Z.-Y., Huang, Q.-F., & Staessen, J. A. (2018) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0006-6 · Cited by 39 · see citing works
Self-citationStergiou, G. S., Karpettas, N., Destounis, A., Tzamouranis, D., Nasothimiou, E., Kollias, A., Roussias, L., & Moyssakis, I. (2014) · American Journal of Hypertension · doi:10.1093/ajh/hpt206 · Cited by 37 · see citing works
Self-citationCurrent Status and Prospects of Health-Related Sensing Technology in Wearable Devices
Cho, J. (2019) · Journal of Healthcare Engineering · doi:10.1155/2019/3924508 · Cited by 33 · see citing works
Hayek, M. A., Giannouchos, T., Lawley, M., & Kum, H.-C. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.44372 · Cited by 32 · see citing works
Asferg, C. L., Andersen, U. B., Linneberg, A., Goetze, J. P., & Jeppesen, J. L. (2014) · Diabetic Medicine · doi:10.1111/dme.12411 · Cited by 26 · see citing works
Braconnier, P., Milani, B., Loncle, N., Lourenco, J. M., Brito, W., Delacoste, J., Maillard, M., Stuber, M., Burnier, M., & Pruijm, M. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002234 · Cited by 26 · see citing works
Alsanjari, O. N., de Lusignan, S., van Vlymen, J., Gallagher, H., Millett, C., Harris, K., & Majeed, A. (2012) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2011.02781.x · Cited by 26 · see citing works
Valera, B., Suhas, E., Counil, E., Poirier, P., & Dewailly, E. (2014) · Journal of the American College of Nutrition · doi:10.1080/07315724.2013.874913 · Cited by 21 · see citing works
Abnormalities of vascular function in resistant hypertension
de La Sierra, A., Larrousse, M., Oliveras, A., Armario, P., Hernández-Del Rey, R., Poch, E., & Roca-Cusachs, A. (2012) · Blood Pressure · doi:10.3109/08037051.2011.622983 · Cited by 21 · see citing works
Stergiou, G. S., Lourida, P., & Tzamouranis, D. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2010.107 · Cited by 18 · see citing works
Self-citationGudmundsdottir, H., Strand, A. H., Høieggen, A., Reims, H. M., Westheim, A. S., Eide, I. K., Kjeldsen, S. E., & Os, I. (2008) · Blood Pressure · doi:10.1080/08037050801972923 · Cited by 14 · see citing works
Silva, R. C. B., Silva, D. A. D., Bastos, J. L. D., Peres, K. G., Peres, M., & González-Chica, D. A. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001128 · Cited by 12 · see citing works
Her, A.-Y., Kim, Y. H., Rim, S.-J., Kim, J.-Y., Choi, E.-Y., Min, P.-K., Lee, B.-K., Hong, B.-K., & Kwon, H. M. (2014) · Anadolu Kardiyoloji Dergisi/The Anatolian Journal of Cardiology · doi:10.5152/akd.2014.5119 · Cited by 12 · see citing works
Clinical implications of white-coat effect among patients attending at a lipid clinic
Bo, M., Comba, M., Canade’, A., Brescianini, A., Corsinovi, L., Astengo, M. A., Sona, A., & Fonte, G. (2008) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2007.08.007 · Cited by 11 · see citing works
Moore, M. N., Picone, D. S., Callisaya, M. L., Srikanth, V., Sharman, J. E., & Schultz, M. G. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13717 · Cited by 9 · see citing works
Pal, R., Mukherjee, S., Bhadada, S. K., Bhansali, A., Puravoor, J., & Behera, A. (2020) · Minerva Endocrinologica · doi:10.23736/s0391-1977.19.03104-3 · Cited by 7 · see citing works
Improving blood pressure control using digital communication methods in Serbia
Tasic, N., Tasic, D., Kovacevic, Z., Filipovic, M., Arsic, M., Bozovic-Ogarevic, S., Despotovic, B., Bojic, M., Maksimovic, Z., Zdravkovic, N., et al. (2022) · Diagnostics · doi:10.3390/diagnostics12040914 · Cited by 1 · see citing works
- Authors
- O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., Parati, G., Pickering, T., Redon, J., Staessen, J., Stergiou, G., & Verdecchia, P.
- Affiliations
- Beaumont Hospital (IE)
- Corresponding author
- O'Brien, Eoin
- ORCID
- Venue
- Journal of Hypertension
- Published
- 2003-05
- Volume
- 21
- Issue
- 5
- Pages
- 821-848
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2142738495
- Cited by
- 1,655
- References
- 181
- Citations by year
- 2026: 10 · 2025: 10 · 2024: 29 · 2023: 44 · 2022: 44 · 2021: 42 · 2020: 62 · 2019: 69 · 2018: 67 · 2017: 72 · 2016: 76 · 2015: 77 · 2014: 79 · 2013: 117 · 2012: 98
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- green
- lirias.kuleuven.be
- Licence
- other-oa
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Lirias (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- blood pressure measurement, ambulatory blood pressure monitoring, home blood pressure monitoring, hypertension diagnosis
- MeSH terms
- Blood Pressure, Cardiovascular Diseases, Europe, Humans, Hypertension, Self Care, Societies, Medical, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review