Abstract

BACKGROUND: Terminal digit and single-number preference may produce inaccuracy and biased results when measuring blood pressure. We describe these preferences in the Syst-Eur randomized placebo-controlled trial of the treatment of isolated systolic hypertension and describe how we sought to eliminate these problems. METHODS: The Data Monitoring Committee of the trial conducted yearly quality control meetings in Belgium and visited the participating centres to check their adherence to the protocol. These meetings involved identifying terminal digit preference, improving blood pressure control and boosting recruitment. RESULTS: The prevalence of use of terminal digit zero when measuring sitting systolic blood pressure (first readings) reduced from an average of 42.4% in the year prior to the date when a centre first randomized a patient to 31.5, 25, 22.3, 26.3, 23.2 and 22% in the subsequent 6 years. This trend was independent of the calendar year during which a centre entered the trial and supports the hypothesis that data-quality monitoring, including the feedback of digit preference to centres, led to a reduction in terminal digit zero preference. In addition, a higher than expected prevalence of the systolic blood pressure value of 148 mmHg was found in the active treatment groups in the double-blind phase. Selection for 148 mmHg persisted over time and constituted a single-number preference bias. This arose from the instruction to investigators to reduce systolic blood pressure to below 150 mmHg. CONCLUSION: Monitoring and feedback of data quality should be undertaken to minimize digit and number preference. Automatic devices should ideally be employed to help to avoid these problems as long as the devices are fully validated and regularly serviced, and providing that readings are not rejected and repeated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200206000-00005

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 58

Metadata

Authors
Wingfield, D., Cooke, J., Thijs, L., Staessen, J. A., Fletcher, A. E., Fagard, R., & Bulpitt, C. J.
Venue
Blood Pressure Monitoring
Published
2002-06
Volume
7
Issue
3
Pages
169-177
ISSN
1359-5237 (ISSN-L)
OpenAlex
W1991565785
Cited by
58
References
2
FWCI
2.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Terminal digit preference and single-number preference in the Syst-Eur trial: influence of quality control. https://app.cochat.ai/papers/10.1097/00126097-200206000-00005
The paper
Wingfield, D., Cooke, J., Thijs, L., Staessen, J. A., Fletcher, A. E., Fagard, R., & Bulpitt, C. J. (2002). Terminal digit preference and single-number preference in the Syst-Eur trial: influence of quality control. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200206000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.