Comparison of Portapres non-invasive blood pressure measurement in the finger with intra-aortic pressure measurement during incremental bicycle exercise
The DOI matches its Crossref record.
Abstract
BACKGROUND AND DESIGN: In order to evaluate the accuracy of continuous, non-invasive blood pressure measurements in the finger during stress, blood pressure was measured in six patients with a Portapres Model 2 during increasing levels of bicycle exercise, using simultaneously registered intra-aortic (aortic arch) pressure as a reference. METHODS: Blood pressure was measured continuously and non-invasively in the left middle finger using the Portapres Model 2 device, at the same time invasively using a pigtail catheter situated in the aortic arch at rest and during and after standardized bicycle exercise. At the end of each stress level, in accordance with the protocol of the Association for the Advancement of Medical Instrumentation, systolic and diastolic blood pressure and pulse values were determined from the non-invasive (Portapres Model 2) and invasive measurements for 15 s each, and the mean values and standard deviations were calculated. RESULTS: Compared with simultaneous invasive blood pressure measurement in the aortic arch, the difference in measured blood pressure value (the value determined by the device minus the value determined invasively) at rest fell within the authorized normal range for German and European blood pressure measurement devices: systolic +1.7 +/- 1.8 mmHg and diastolic -3.7 +/- 6.2 mmHg. The difference in measured value increased with the stress level. CONCLUSION: Blood pressure and pulse can be determined reliably and accurately using the Portapres Model 2, non-invasively, both at rest and at low-to-moderate levels of stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 470
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Nyklíček, I., Mommersteeg, P. M. C., Van Beugen, S., Ramakers, C., & Van Boxtel, G. J. (2013) · Health Psychology · doi:10.1037/a0032200 · Cited by 194
“Participants’ blood pressure was measured continuously using PORTAPRES (Eckert & Horstkotte, 2002), based on finger plethysmography obtained from a cuff placed around the middle finger of the nondominant hand.”
MethodExercise blood pressure: Clinical relevance and correct measurement
Sharman, J. E., & LaGerche, A. (2015) · Journal of Human Hypertension · doi:10.1038/jhh.2014.84 · Cited by 142
Hemodynamic profiles of functional and dysfunctional forms of repetitive thinking
Ottaviani, C., Brosschot, J. F., Lonigro, A., Medea, B., Van Diest, I., & Thayer, J. F. (2017) · Annals of Behavioral Medicine · doi:10.1007/s12160-016-9851-3 · Cited by 29
Metadata
- Authors
- Eckert, S., & Horstkotte, D.
- Venue
- Blood Pressure Monitoring
- Published
- 2002-06
- Volume
- 7
- Issue
- 3
- Pages
- 179-183
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2329584236
- Cited by
- 65
- References
- 0
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Portapres non-invasive blood pressure measurement in the finger with intra-aortic pressure measurement during incremental bicycle exercise. https://app.cochat.ai/papers/10.1097/00126097-200206000-00006
- The paper
- Eckert, S., & Horstkotte, D. (2002). Comparison of Portapres non-invasive blood pressure measurement in the finger with intra-aortic pressure measurement during incremental bicycle exercise. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200206000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.