CoChat

Twenty-four hour ambulatory blood pressure monitoring pattern of resistant hypertension

Muxfeldt, Elizabeth S., Bloch, Katia V., Nogueira, Armando R., Salles, Gil F. · 2003 · Blood Pressure Monitoring
Cited by 136

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Ambulatory blood pressure monitoring (ABPM) is a tool to diagnose resistant hypertension (RH). The objective of this study is to describe the pattern of 24-h ABPM in patients using at least three anti hypertensive drugs without blood pressure (BP) control, classifying them as true RH or white-coat RH. METHODS: A cross-sectional study involving resistant hypertensives that were submitted to clinical, laboratory and 2D-echocardiographic evaluation. Ambulatory blood pressure monitoring was used to diagnose true or white-coat RH. The chi-squared test was used for comparisons among categorical variables and Kruskall-Wallis test for continuous ones. RESULTS: Of the 286 patients, 161 (56.3%) were classified as true RH and 125 (43.7%) as white-coat RH. Sex, age, office BP and the cardiovascular risk factors for both groups were similar. True resistant hypertensives had more target organ damage then white-coat resistant hypertensives; nephropathy (40.1 versus 23.9%, P=0.007) and left ventricular hypertrophy (83.3 versus 76.3%, P=0.05). In ABPM, the true RH group had a smaller nocturnal systolic and diastolic BP reduction (6.4+/-8.8 versus 9.8+/-7.5 mmHg, P=0.0004; 10.4+/-9.6 versus 13.6+/-9.2 mmHg, P=0.001) and 68.7% of them were non-dippers versus 49.6% in the white-coat RH group (P=0.001). True RH also had a larger 24 h pulse pressure (65.8+/-13.7 versus 51.5+/-10.0 mmHg, P < 0.0001). CONCLUSIONS: Ambulatory blood pressure monitoring is a fundamental tool to diagnose RH, and to check treatment efficacy. The presence of a greater pulse pressure and a lower nocturnal blood pressure reduction in true RH patients may be responsible for this increased cardiovascular risk profile.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200310000-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 136

Metadata

Authors
Muxfeldt, E. S., Bloch, K. V., Nogueira, A. R., & Salles, G. F.
Venue
Blood Pressure Monitoring
Published
2003-10
Volume
8
Issue
5
Pages
181-185
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2053812411
Cited by
136
References
0
FWCI
2.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Twenty-four hour ambulatory blood pressure monitoring pattern of resistant hypertension. https://app.cochat.ai/papers/10.1097/00126097-200310000-00001
The paper
Muxfeldt, E. S., Bloch, K. V., Nogueira, A. R., & Salles, G. F. (2003). Twenty-four hour ambulatory blood pressure monitoring pattern of resistant hypertension. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200310000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.