CoChat

Prediction of ischaemic and haemorrhagic stroke by self-measured blood pressure at home: the Ohasama study

Open access
Ohkubo, Takayoshi, Asayama, Kei, Kikuya, Masahiro, Metoki, Hirohito, Obara, Taku, Saito, Shin, Hoshi, Haruhisa, Hashimoto, Junichiro, Totsune, Kazuhito, Satoh, Hiroshi, Imai, Yutaka · 2004 · Blood Pressure Monitoring
Cited by 59

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To examine the predictive value of self-measured blood pressure values taken at home (home blood pressure) for risk of stroke and subtypes. METHODS: We obtained home blood pressure measurements from 1702 people, aged > or =40 years, without a history of stroke, in the general population in Japan, and continued follow-up after a mean period of 10.6 years. The prognostic significance of blood pressure for stroke risk was examined using the Cox proportional hazards regression model, which was adjusted for possible confounding factors. RESULTS: There was a linear relationship between home blood pressure and risk of stroke and subtypes. On average, each 10/5 mmHg elevation in home systolic/diastolic blood pressure respectively, was associated with an approximately 30/20% respectively, higher risk of total stroke. A similar relationship was observed for the risk of haemorrhagic stroke (intracerebral and subarachnoid haemorrhage), and the risk of ischaemic stroke [cerebral infarction and transient ischaemic attack (TIA)]. The risk of stroke and subtypes showed a significantly greater relation with home blood pressure values compared to conventional blood pressure values. CONCLUSIONS: This is the first study to demonstrate that home blood pressure is an independent predictor for haemorrhagic and ischaemic stroke, in the general population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200412000-00009

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 59

Metadata

Authors
Ohkubo, T., Asayama, K., Kikuya, M., Metoki, H., Obara, T., Saito, S., Hoshi, H., Hashimoto, J., Totsune, K., Satoh, H., & Imai, Y.
Venue
Blood Pressure Monitoring
Published
2004-12
Volume
9
Issue
6
Pages
315-320
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2089064596
Cited by
59
References
1
FWCI
2.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of ischaemic and haemorrhagic stroke by self-measured blood pressure at home: the Ohasama study. https://app.cochat.ai/papers/10.1097/00126097-200412000-00009
The paper
Ohkubo, T., Asayama, K., Kikuya, M., Metoki, H., Obara, T., Saito, S., Hoshi, H., Hashimoto, J., Totsune, K., Satoh, H., & Imai, Y. (2004). Prediction of ischaemic and haemorrhagic stroke by self-measured blood pressure at home: the Ohasama study. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200412000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.