CoChat

Are published characteristics of the ambulatory blood pressure generalizable to rural Chinese? The JingNing population study

Open access
Li, Yan, Wang, Ji-Guang, Gao, Pingjin, Guo, Huifeng, Nawrot, Tim, Wang, Guliang, Qian, Yuesheng, Staessen, Jan A, Zhu, Dingliang · 2005 · Blood Pressure Monitoring
Cited by 69

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Objective We investigated the ambulatory blood pressure (BP) in rural Chinese and compared its characteristics with those reported in other population-based studies. Methods We enrolled inhabitants from six villages of the JingNing County, China. We recorded the ambulatory BP using 90207 SpaceLabs monitors. Trained physicians measured the conventional BP at the participants' homes. Hypertension was defined as a conventional BP of ≥140/≥90 mmHg or a condition requiring the intake of antihypertensive drugs. Using MEDLINE, we searched for population-based studies on ambulatory BP monitoring. Results The 356 participants (12–86 years) included 192 (53.9%) women and 117 (32.9%) hypertensive patients. In all participants, systolic/diastolic BP averaged 129/80 mmHg at home. The ambulatory BP means were 121/77 mmHg over 24 h, 126/81 mmHg during daytime (0800 to 1800 h) and 112/70 mmHg during night-time (2200 to 0400 h). The awake and asleep BPs averaged 126/82 and 112/70 mmHg, respectively. Using previously published definitions of daytime (1000 to 2000 h) and night-time (midnight to 0600 h) instead of those given above, inflated the BP differences with the awake and asleep BPs from 0.4/0.2 to 1.2/1.0 mmHg and from 0.3/0 to 1.4/1.6 mmHg, respectively. Compared with daytime values, conventional BP was 2.7/3.1 mmHg lower in normotensive individuals, but 14.9/1.3 mmHg higher in hypertensive patients. In our normotensive individuals, the whole-day and night-time diastolic BPs were from 1 to 4 mmHg and from 3 to 7 mmHg higher than in five other population studies in Caucasians or Japanese, whereas night-time BP in our participants was 9/5 mmHg lower than in Chinese living in Taiwan. Conclusions We demonstrated significant differences in the characteristics of the ambulatory blood pressure across Asian and Caucasian populations. To what extent different activity patterns and genetic and environmental factors explain this context-dependency remains to be clarified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200506000-00003

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 69

Metadata

Authors
Li, Y., Wang, J.-G., Gao, P., Guo, H., Nawrot, T., Wang, G., Qian, Y., Staessen, J. A., & Zhu, D.
Venue
Blood Pressure Monitoring
Published
2005-06
Volume
10
Issue
3
Pages
125-134
ISSN
1359-5237 (ISSN-L)
OpenAlex
W4232022914
Cited by
69
References
5
FWCI
3.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Are published characteristics of the ambulatory blood pressure generalizable to rural Chinese? The JingNing population study. https://app.cochat.ai/papers/10.1097/00126097-200506000-00003
The paper
Li, Y., Wang, J.-G., Gao, P., Guo, H., Nawrot, T., Wang, G., Qian, Y., Staessen, J. A., & Zhu, D. (2005). Are published characteristics of the ambulatory blood pressure generalizable to rural Chinese? The JingNing population study. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200506000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.