Analysis of the Dysfunctional Eustachian Tube by Video Endoscopy
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Human eustachian tubes with known pathologic conditions of the ear were inspected endoscopically, and video recordings were made for slow-motion analysis of the pathophysiologic changes. SETTING: Ambulatory office in a tertiary referral center. SUBJECTS: Forty-four adults with 64 ears having pathologic conditions. INTERVENTIONS: Transnasal endoscopic examination of the nasopharyngeal opening of the eustachian tube during rest, swallowing, and yawning to study the dilatory movements of the eustachian tube. MAIN OUTCOME MEASURES: Slow-motion video analysis of the dilatory movements of the eustachian tube. RESULTS: Sixty-four ears and eustachian tubes with pathologic changes were studied. Tubal function was graded on (1) the extent of lateral excursion and progression of dilatory wave as estimates of tensor veli palatini and dilator tube muscle function, reduced function being observed in 43 tubes; (2) the degree of mucosal disease, which was significant in 48 tubes; (3) obstructive mucosal changes, which were present in 15 tubes; (4) ease and frequency of tubal dilation with maneuvers-26 tubes opened moderately, 21 opened minimally, and 11 were unable to open; and (5) patulous tubes-all 6 clinically patulous tubes showed concavities in the superior third of the tube, which is convex in normal subjects. All tubes with active pathologic conditions of the ear (otitis media with effusion, tympanic membrane retraction, draining ear, cholesteatoma) had significant abnormalities. A correlation could not be made between the severity of middle ear disease and the severity of observed eustachian tube dysfunction. CONCLUSIONS: Slow-motion endoscopic video analysis is a potentially useful technique in classifying types of pathologic changes in the eustachian tube. Additional studies of dysfunctional tubes are needed to predict outcomes in operative ear cases and to design intratubal therapy for chronically dysfunctional tubes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Synchronous movement of tympanic membrane (TM) with respiration during ear endoscopic examination is the gold standard for identifying PET [6]”
From Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube (2024) · cites this paper as [6]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 11
- Honjo, 1981, Arch Otolaryngol, 107, 350, 10.1001/archotol.1981.00790420024005 · doi:10.1001/archotol.1981.00790420024005
- Bluestone, 1981, Ann Otol Rhinol Laryngol, 90, 552, 10.1177/000348948109000608 · DOI · Paper page
- Prades, 1988, Surg Radiol Anat, 20, 335, 10.1007/s00276-998-0335-4 · doi:10.1007/s00276-998-0335-4
- Takahashi, 1996, Eur Arch Otorhinolaryngol, 253, 42, 10.1007/BF00176702 · DOI
- Kimura, 1989, Nippon Jibiinkoka Gakkai Kaiho, 92, 233, 10.3950/jibiinkoka.92.233 · doi:10.3950/jibiinkoka.92.233
- Chays, 1995, Tech Chir, 24, 773
- Edelstein, 1994, Am J Otol, 15, 50
- Klug, 1999, Am J Otol, 20, 299
- Hopf, 1991, Laryngorhinootologie, 70, 391, 10.1055/s-2007-998060 · DOI
- Poe, 2000, Am J Otol, 21, 602
- Barsoumian, 1998, Cleft Palate Cr Fac J, 35, 101, 10.1597/1545-1569(1998)035<0101:AASOTT>2.3.CO;2 · DOI
Cited by
Diagnosis and Management of the Patulous Eustachian Tube
Poe, D. S. (2007) · Otology & Neurotology · doi:10.1097/mao.0b013e31804d4998 · Cited by 185
“This wall of the valve is normally convex and bulges into the posteromedial wall to close the valve in the resting position (10).”
BackgroundSelf-citationBalloon Dilation of the Cartilaginous Eustachian Tube
Poe, D. S., Silvola, J., & Pyykkö, I. (2011) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599811399866 · Cited by 160
“Dilatory dysfunction of the ET is most commonly due to mucosal inflammation that limits dilation of the valve, causing insufficient ventilation of the middle ear.(4) Eustachian tuboplasty consisting of a partial resection of inflamed mucosa, submucosa, and cartilage, from the intraluminal posteromedial wall, where the…”
BackgroundSelf-citationAdil, E., & Poe, D. (2014) · Current Opinion in Otolaryngology & Head and Neck Surgery · doi:10.1097/moo.0000000000000020 · Cited by 104
“plasia and excessive mucus can be associated with ETD, especially when the adenoid is in contact with the posterior cushion in which it may even physically interfere with tubal dilation [3].”
BackgroundSelf-citationSwarts, J. D., Alper, C. M., Luntz, M., Bluestone, C. D., Doyle, W. J., Ghadiali, S. N., Poe, D. S., Takahashi, H., & Tideholm, B. (2013) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599812472631 · Cited by 65
Self-citationAssessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube
Attia, A. A. A., Abou-Setta, A. E. A., & Ashary, Y. M. (2024) · The Egyptian Journal of Otolaryngology · doi:10.1186/s43163-024-00579-4
Metadata
- Authors
- Poe, D. S., Abou-Halawa, A., & Abdel-Razek, O.
- Venue
- Otology & Neurotology
- Published
- 2001-09
- Volume
- 22
- Issue
- 5
- Pages
- 590-595
- ISSN
- 1531-7129
- Semantic Scholar
- 79a204169e1ebbe1a2d4075ad09e22b83ce8f5ea
- Cited by
- 98
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.